FREE SHIPPING throughout Europe

SCHNEIDER ELECTRIC

SCHNEIDER ELECTRIC

Schneider Electric is a company specializing in energy management and automation, present in over 100 countries. It offers integrated solutions for various market segments.

The company's objective is to allow everyone to make the best use of energy and resources, combining progress and sustainability.

At Schneider they call this philosophy Life Is On

1534 products


  • METSEPM5110 | Schneider Electric PM5110 power meter 96x96

    SCHNEIDER ELECTRIC METSEPM5110 | Schneider Electric PM5110 power meter 96x96

    Schneider Electric PM5110 power meter 96x96 METSEPM5110 The device is a flush mount energy meter with a 96mm x 96mm backlit LCD display. The meter ensures 0.5S accuracy class according to IEC 62053-22 and 64 samples per cycle. The device measures energy, active and reactive power, voltage, current, frequency, power factor and up to the 15th harmonic. The meter operates on a 50 or 60 Hz mains and accepts supply voltages of 100 to 415 V AC and 125 to 250 V DC. The rated line current for this meter is 1A or 5A input and supports single-phase and neutral, three-phase, or three-phase and neutral configurations. The measurement voltage range between phases is 35 to 690 V AC, 47 to 63 Hz. The measurement range between phase and neutral is 20 to 400VAC, 47 to 63 Hz. The communication protocol consists of by Modbus RTU and ASCII 2 cables with RS485 port. The meter also features a digital pulse output and 33 configurable alarms. Product Dimensions: Width 3.78 inches (96 mm), Depth 2.83 inches (72 mm), Height 3.78 inches (96 mm); weight 13.4 oz (380 g). Technical dataRangePowerLogicProduct namePowerLogic PM5000Device name PM5110Product typeMeasuring instrumentTechnical characteristicspower quality analysisUp to the 15th harmonicApplicationEnergy monitoringtype of measurementCurrentVoltageFrequencyPower factorEnergyActive and reactive powersupply voltage90...450 V AC 45...65 Hz100 ...300 V DCMains frequency50 Hz60 HzRated current [In]1 A 5 Atype of network1P + N3P + N3Ppower absorbed in VA11 VA at 415 Vlocal signaling80 ms 120 V AC typical100 ms 230 V AC typical100 ms 415 V AC typical50 ms 125 V DC typicaldisplay typeMonochrome graphic LCDdisplay resolution128 x 128sampling rate64 samples/ cyclecurrent measurement50…8500 mAanalog input typeVoltage (impedance 5 MOhm)Current (impedance measurement voltage35…760 V AC 45...65 Hz between phase and phase20…440 V AC 45...65 Hz between phase and neutralfrequency measurement range45…65 Hznumber of inputs0measurement precision Active energy +/- 0.5%Reactive energy +/- 2%Active power +/- 0.5%Apparent power +/- 0.5%Frequency +/- 0.05%Power factor +/- 0.5Current +/- 0.5%Voltage +/- 0.5%Apparent energy +/- 0.5 %Reactive power +/- 2%precision classClass 0.5S active energy compliant with IEC 62053-22number of outputs1 digitalcommunication port protocolModbus RTU and ASCII at 9.6 - 19.2 - 38.4 kbaud odd/even or none - 2 wires, 2500 V insulationJBUScommunication port protocolRS485data loggingTime indicationMin/max of instantaneous valuesconnections - terminalsVoltage circuit: screw terminal4Control circuit: screw terminal2 Currenttransformer: screw terminal6I/O circuit: screw terminal6RS485 connection: screw terminal4InstallationBuilt-insupport assemblyStructureReference standardsUL 61010-1CEI EN 50470-3CEI EN 50470-1IEC 62053-22 :2020IEC 60529IEC 62053-24IEC 61557-12:2015IEC 62053-23:2020IEC 62052-11:2020IEC 62052-3 1:2015 Product certificationsCE conforming to IEC 61010-1CULus conforming to UL 61010-1width96 mmdepth72 mmheight96 mmproduct weight380 g

    €529,20

  • XPSUAK12AP | Schneider-Electric safety module UAK 24V M.SCREW

    SCHNEIDER ELECTRIC XPSUAK12AP | Schneider-Electric safety module UAK 24V M.SCREW

    Schneider-Electric safety module UAK 24V M.SCREW XPSUAK12AP The product is part of the XPS Universal security module range. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP and NPN sensors, RFID safety switches, safety barriers and sensitive mats/edges. PresentationProduct rangeHarmony Safety AutomationProduct typeSafety modulesafety module name XPSUAKsafety module applicationMonitored antivalent contactsFor emergency, protection and barrier monitoring4-wire pressure sensor monitoringModule function Emergency stop button with 2 NC contactsSafety monitoring with 1 or 2 limit switchesControl of 2 PNP sensorsMagnetic switch monitoringSafety barrier control RFID safety switch controlSafety barrier monitoring (ESPE)Safety mat controlProximity sensor monitoringMonitoring 1 PNP + 1 NPN sensor Safety levelCan reach PL e/category 4 for NO relay contact conforming to ISO 13849-1Can reach SILCL 3 for NO relay contact conforming to IEC 62061Can reach SIL 3 for NO relay contact conforming to IEC 61508Can reach PL c/category 1 for NC relay contact conforming to ISO 13849-1Can reach SILCL 1 for NC relay contact conforming to IEC 62061Can ' achieve SIL1 for NC relay contact conforming to IEC 61508Reliability data safetyMTTFd > 30 years conforming to ISO 13849-1Dcavg >= 99 % conforming to ISO 13849-1PFHd = 1.13E-09 conforming to ISO 13849-1HFT = 1 conforming to IEC 62061PFHd = 1.13E-09 conforming to IEC 62061SFF > 99% conforming to IEC 62061HFT = 1 conforming to IEC 61508-1PFHd = 1.13E-09 conforming to IEC 61508-1SFF > 99% conforming to IEC 61508-1Type = B conforming to IEC 61508-1topology of the networkNC doublePNP doubleAntivalent double OSSD doubleconnections - terminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexibleTerminal block removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible double conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with maskRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with maskVoltage nominal power supply [Us]24 V AC - 15...10 %24 V DC - 20...20 %Technical characteristicssynchronization time between inputs 0.5 s 2 s 4 sType of startingAutomatic/manual/monitoredPower absorbed in W2.0 W 24 V DCPower consumption in VA5.0 VA 24 V AC 50/60 Hztype of input protectionInternal, electronicsafety outputs2 NO + 1 NCsafety inputs2 safety input 24 V DC 5 mAmaximum wire resistance 500 OhmInput compatibilityNormally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850Double antivalent conforming to ISO 14119Double OSSD conforming to IEC 61496-1-23-wire PNP proximity sensorsRated operational current [Ie]5 A AC-1 for NO relay contact3 A AC-15 for NO relay contact5 A DC-1 for NO relay contact3 A DC-13 for NO relay contact 3 A AC-1 for NC relay contact1 A AC-15 for NC relay contact3 A DC-1 for NC relay contact1 A DC-13 for NC relay contactcontrol outputs 3 configurable on/off pulsed outputinput/output typePulsed semiconductor signaling output. 24 V DC, 20 mA Z1, non-safety relatedConventional thermal current in air [Ith]8 Aassociated fuse rating10 A gG for output circuit NO relay conforming to IEC 60947-1minimum output current10 mA per relay outputminimum output voltage12 V per relay outputRated insulation voltage [Ui]250 V (pollution degree 2) conforming to IEC 60947-1Rated impulse withstand voltage [Uimp]4 kV overvoltage category II conforming to IEC 60947-1Installation35 mm symmetrical DIN raildepth120 mmheight100 mmwidth22.5 mmproduct weight0.200 kg

    €181,28

  • LUB12 | Schneider Electric Power base - TeSys U - 12 A - Screw terminal control

    SCHNEIDER ELECTRIC LUB12 | Schneider Electric Power base - TeSys U - 12 A - Screw terminal control

    Schneider Electric Power base - TeSys U - 12 A - Control screw terminals LUB12 TeSys U standard power base, 3 pole (3NO), 12 A/ 690 V, to be completed with a LUC control unit to form a TeSys U reversing starter controller, for 3-speed motor applications phases up to 5.5 kW at 400 V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to get an "all in one" starter controller with protection functions and basic or advanced control. It is equipped with a connection terminal block and closing shutters that cover the empty cavities. It provides a high breaking capacity Icu 50 kA at 400 V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm wide), DIN rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in combination with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), compliant with Green Premium (RoHS/REACh). Range: TeSysProduct Name: TeSys UltraDevice Name: LUBProduct Type : Power base with 1 direction of travelApplication: Motor control Motor protectionNumber of Poles: 3PAptitude for Insulation: YesNominal Operational Voltage [Ue]: 690 V AC for Power CircuitMains Frequency: 40...60 HzConventional Thermal Current In Air [Ith]: 12 ARated Operational Current [Ie] 12 A at 12 A at 500 V 9 A at 690 VUsage Category AC-43AC-44AC-41Rated Breaking Capacity Service [Ics]50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 VAuxiliary Contact Composition : 1 NO + 1 NCType of Auxiliary Contacts connected contact type (1 NO + 1 NC) conforming to IEC 60947-4-1mirror contact type (1 NC) conforming to IEC 60947-1 typical current consumption130 mA at 24 V DC I maximum during closing with LUCA, LUCB, LUCC, LUCD140 mA at 24 V AC I maximum during closing with LUCA, LUCB, LUCC, LUCD150 mA at 24 V DC I maximum during closing with LUCM280 mA at 110...220 V DC I maximum during closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum during closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum during closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum during closing with LUCA, LUCB, LUCC, LUCD35 mA at 110...220 V DC I rms fixed with LUCA, LUCB, LUCC, LUCD35 mA at 110...240 V AC I rms fixed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V AC I rms fixed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V DC I rms fixed with LUCA, LUCB, LUCC, LUCD60 mA at 24 V DC I rms fixed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V AC I rms fixed with LUCA, LUCB , LUCC, LUCD70 mA at 24 V DC I rms fixed with LUCMheat dissipation2 W for control loop with LUCA, LUCB, LUCC, LUCD 1.7 W per control circuit with LUCMSafety reliability levelB10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1B10d = 20000000 cycles Contactor with mechanical load compliant with EN /ISO 13849-1operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at >= 72 V closing with LUCA , LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for circuit control circuit75 ms closing with LUCM for control circuitMechanical life15 McyclesMaximum operating speed3600 cycles/hProduct certificationsCEULCSACCCEACASEFAATEXMarinaStandardsEN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase spreaderCSA C22.2 No 60947-4-1, with phase spreader phaseRated insulation voltage [Ui]690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1 600V compliant with CSA C22.2 No 60947-4-1Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-6-2safe circuit separation400 V SELV between auxiliary and control circuits conforming to IEC 60947-1 appendix N400 ​​V SELV between auxiliary or control circuit and main circuit conforming to IEC 60947-1 appendix N type of fixingClip-on (DIN rail)Screw fixed (Plate)connections - terminalsControl circuit: screw fixing terminals 1 cables 0 ,34…1.5 mm² flexible with cable terminationControl circuit: screw fixing terminals 1 cables 0.75…1.5 mm² flexible without cable terminationControl circuit: screw fixing terminals 1 cables 0.75…1.5 mm² rigidControl circuit: screw fixing terminals 2 cables 0.34…1.5 mm² flexible with cable terminationControl circuit: screw fixing terminals 2 cables 0.75…1.5 mm² flexible without cable terminationControl circuit: screw fixing terminals 2 cables 0.75…1.5 mm² rigidPower circuit: screw fixing terminals 1 cables 1 …10 mm² rigidPower circuit: screw fixing terminals 1 cable 1…6 mm² flexible with cable terminationPower circuit: screw fixing terminals 1 cable 2.5…10 mm² flexible without cable termination Power circuit: screw fixing terminals 2 cables 1…6 mm² flexible with cable terminationPower circuit: screw fixing terminals 2 cables 1…6 mm² rigidPower circuit: screw fixing terminals screw fixing 2 cables 1.5…6 mm² flexible without cable terminationtightening torqueControl circuit: 0.8…1.2 Nm flat screwdriver 5 mmCircuit control: 0.8…1.2 Nm Philips no 1 screwdriver 5 mmPower circuit: 1.9…2.5 Nm flat screwdriver 6 mmPower circuit: 1.9…2.5 Nm Philips No 2 screwdrivers 6 mmPower circuit: 1.9…2.5 Nm pozidriv No 2 screwdrivers 6 mmwidth45 mmheight 154 mmdepth126 mmproduct weight0.9 kgCompatibility codeLUB

    €64,39

  • A9DE3616 | Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC

    SCHNEIDER ELECTRIC A9DE3616 | Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC

    Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC A9DE3616 This Acti9 iCV40 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole, 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. PresentationRangeActi9Product nameActi9 iCV40Product typeThermal circuit breaker differential (RCBO)Device nameiCV40NApplicationDistributionNumber of poles1P + Nnumber of protected poles 1 neutral position LeftRated current [In] 16 AType of AC networkRelease technologyMagnetothermalcurve code Cdifferential sensitivity30 mADifferential protection timingInstantaneoustype of differential protectionAC typeInterrupting capacity6000 A Icn compliant with CEI EN 61009- 2-1 at 230 V AC 50/60 HzSuitable for isolationComplies with EN/IEC 60947-2quality marksIMQ"EAC" VDETechnical characteristicsComplementaryStarting pointMains frequency50/60 HzRated operational voltage [Ue ]230 V AC 50/60 Hzmagnetic trip limit5...10 x InResidual current trip technology"Independent from the voltage"Rated service breaking capacity [Ics]6000 A 100 % Icn at 230 V AC 50/60 Hz compliant with CEI EN 61009-2-1rated breaking and making capacityIdm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1limiting class3 compliant with CEI EN 61009-2-1Rated insulation voltage [Ui]400 ​​V AC 50/60 HzRated impulse withstand voltage [Uimp] 4 kVcontact position signaling YesType of control LeverLocal signalingFault indicationON/OFF indicationInstallationCouplingInstallationDIN raildistribution comb compatibilityUpper or lower part: toothconnection pitch9 mm between phase and neutralpitch 9 mm 4height 85 mmwidth 36 mmdepth 73 mmproduct weight 210 gColor White

    €146,68

  • A9S60232 | Schneider Electric iSW 2P 32A disconnect switch

    SCHNEIDER ELECTRIC A9S60232 | Schneider Electric iSW 2P 32A disconnect switch

    Schneider Electric  iSW 2P 32A disconnect switch A9S60232 This Acti9 iSW is a modular and reliable disconnector. It is a 2P, with a rated current of 32 A and an operating voltage of 415 V AC. The electrical resistance reaches up to 30000 cycles and the mechanical resistance reaches up to 300000 cycles. The operating temperature ranges from -20°C to +50°C. PresentationRangeActi9Product nameActi9 iSWProduct typeSwitch operating-disconnectorDevice nameiSWApplicationControlNumber of poles2PUsage categoryAC- 22ASuspension suitabilityYesTechnical characteristicsRated operational current [Ie]32 A at 415 V AC 50/60 HzRated operational voltage [Ue]415 V AC 50/60 HzRated insulation voltage [Ui]500 V AC 50 /60 Hz compliant with CEI EN 60669-2-4Rated impulse withstand voltage [Uimp]4 kVType of control LeverLocal signalingON/OFF indicationcontact position signalingYesInstallationFixedInstallation DIN railpitch 9 mm2height77 mmwidth18 mmdepth70 mmColorWhiteMechanical life300000 cycleslife electrical30000 cyclesconnections - terminalsCage terminals - 10 mm² - rigidCage terminals - 10 mm² - flexibleCage terminals - 10 mm² - flexible with ring nutwire stripping length9 mmTightening torque1.2 NmEnvironmentReference standards CEI EN 60669-2-4degree of protection IPIP4degree of pollution2tropicalization2relative humidity95% at 55 °C Ambient temperature-20…50 °CStorage temperature-40…70 °C

    €25,14

  • RSL1PVBU | Schneider Electric "SLIM" interface relay on screw base with LED and protection circuit, 24 V

    SCHNEIDER ELECTRIC RSL1PVBU | Schneider Electric "SLIM" interface relay on screw base with LED and protection circuit, 24 V

    Schneider Electric "SLIM" interface relay on screw base with LED and protection circuit, 24 V RSL1PVBU The Schneider Electric Slim RSL interface plug-in relay has a coil control voltage of 24 Vdc and has a SPDT (double throw single pole) switching contact rated at 6 Ampere. It has LED indicators and screw connectors. This slim interface plug-in relay reflects Schneider Electric's experience in the relay industry since 1924, helping to reduce cabinet size and at the same time increase machine reliability for industrial machinery, packaging, textile industry , HVAC, automation control panels, low/medium voltage distribution panels, motor controls, PLC interfaces, power supplies, building or medical equipment, lighting controls. It has a wide choice of contacts for high rated current use. It also offers an LED indicator and protection circuit. Technical dataProduct rangeHarmony Electromechanical Relaysrange nameInterface relayProduct type Pre-assembled plug-in relay with socketDevice nameRSLContact composition and type1 C/OContact operationStandardcontrol voltage [Uc]24 V DCConventional thermal current in enclosure [Ithe]6 A at -40…55 °CStatus LEDWithpin shapeFlat (PCB type) Type of fixingPlastic compression springmedium resistance3390 Ohm mains: DC at 23 °C +/- 10 % Rated insulation voltage [Ui]250 V conforming to IEC277 V conforming to cULRated impulse withstand voltage [Uimp]6 kV conforming to IECContact materialSilver alloy (AgSnO2)Rated operational current [Ie]6 A 1 C/O (AC -1/DC-1) IEC/UL compliantMinimum switching current100 mAmaximum switching voltage277 VMinimum switching voltage12 Vmaximum switching capacity1500 VA150 Wminimum switching capacity120 mWoperating rateMechanical durability10000000 cycleselectrical life60000 cycles for resistive load, 6 A at 250 V, AC-1operating time5 ms reset12 msmarkingCEprotection categoryRT IIItest levelsLevel A group mountingoperating positionAny positionheight78.6 mmwidth 6.2 mmdepth95 mmDescription of ISO terminals n°1(A1-A2)CO(11-12-14)OCsale indivisible quantity10product weight0.029 kgcurrent load6 A at 250 V AC Mounting distance of 0.5average absorption in W0.17 W, DCthreshold voltage dropout >= 0.05 Ucarrangement of contact terminalsSeparateconnections - terminalsScrew connectors, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable endScrew connectors, 1 x 0.2...1 x 2.5 mm² (AWG 24 ...AWG 14) solid without cable endtightening torqueSafety reliability dataB10d = 60000Control typeWithout buttonInstallation35 mm symmetrical DIN rail

    €9,93

  • A9P52616 | Schneider Electric iC40a 1P+N C 16A 4500A circuit breaker

    SCHNEIDER ELECTRIC A9P52616 | Schneider Electric iC40a 1P+N C 16A 4500A circuit breaker

    Schneider Electric Circuit breaker iC40a 1P+N C 16A 4500A A9P52616 This Acti9 iC40 product is a low voltage circuit breaker (MCB). It is a 1P+N switch with 1 protected pole and 16A rated current In and tripping curve C. The rated short-circuit breaking capacity reaches up to 6kA at 230VAC in compliance with the EN/IEC 60947-2 standard and 4500A at 230VAC in compliance with EN/IEC 60898-1. This product complies with industrial standards EN/IEC 60898-1 and residential standards EN/IEC 60947-2. This circuit breaker combines the functions of circuit protection against short circuits and overload current, control and isolation. Installation and wiring are simplified with clip-on functionality and easy maintenance. It has an electrical resistance of up to 20,000 cycles and a mechanical resistance of up to 20,000 cycles. The EU operating voltage is 230 V AC. The rated insulation voltage Ui is 400 V AC. The rated impulse withstand voltage Uimp is 4 kV. The operating frequency is 50 Hz or 60 Hz. It can be mounted on a DIN rail for modular installation. Its width is 2 steps of 9 mm. The pollution degree is 3. The color of the product is white (RAL 9003). Overall dimensions are (H) 18mm x (W) 85mm x (D) 74mm. The weight is 120 g. According to IEC 60529, the degree of protection is IP20 and IP40 in the cabinet. The operating temperature is between -25°C and 70°C. The storage temperature is between -40°C and 85°C. RangeActi9Product nameActi9 iC40Product typeModular switchDevice nameiC40ApplicationDistributionNumber of poles1P + Nnumber of protected poles1neutral positionLeftRated current [In]16 A Type of networkCARelease technologyMagnetothermalcurve codeCInterrupting capacity6 kA Icu compliant with EN/IEC 60947-2 at 230 V AC 50/60 Hz4500 A Icn compliant with CEI EN 60898-1 at 230 V AC 50/60 HzAptitude for sectioningYes compliant with EN/IEC 60947-2quality marksKEMAIMQ Technical dataMains frequency50/60 HzRated operational voltage [Ue]230 V AC 50/60 Hzmagnetic trip limit5...10 x In compliant with CEI EN 60898-18 x In +/- 20 % compliant with EN/IEC 60947-2Rated service breaking capacity [Ics] 4500 A 100 % Icn at 230 V AC 50/60 Hz conforming to CEI EN 60898-14.5 kA 75 % Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2class limitation3 conforming to CEI EN 60898-1Rated insulation voltage [Ui]400 V AC 50/60 Hz conforming to EN/IEC 60947-2 Rated impulse withstand voltage [Uimp]4 kV conforming to EN/IEC 60947-2contact position signalingYes Control typeLeverLocal signalingON/OFF indicationTrip indicatorInstallationCoupling InstallationDIN railpitch 9 mm2height85 mmwidth 18 mmdepth74 mmproduct weight120 gColorWhiteMechanical durability20000 cycleselectrical durability20000 cyclesDescription of locking options Padlock deviceconnections - terminalsCage terminals upper or lower part1…10 mm² flexibleCage terminals upper or lower part1…16 mm² rigidlength wire stripping14 mm for upper or lower part connectiontightening torque2 Nm upper or lower partdifferential protectionSeparate block

    €13,50

  • A9S60432

    SCHNEIDER ELECTRIC A9S60432 | SCHNEIDER ELECTRIC ISW 4P 32A SWITCH DISCONNECTOR

    Schneider Electric iSW 4P 32A disconnect switch A9S60432  This Acti9 iSW is a modular and reliable disconnector. It is a 4P, with a rated current of 32 A and an operating voltage of 415 V AC. The electrical resistance reaches up to 30000 cycles and the mechanical resistance reaches up to 300000 cycles. The operating temperature ranges from -20°C to +50°C. The storage temperature ranges from -40°C to +70°C. The degree of protection is IP20 and IP40 in one enclosure. It can be installed on a DIN rail. Width in 9mm steps is 4. Overall dimensions are (H)36mm x (W)77mm x (D)70mm. This disconnector is used for control. This product complies with EN/IEC 60669-2-4. Product Type: Switch disconnectorDevice Name: iSWApplication: ControlNumber of Poles: 4PUsage Category: AC-22AAbility to Disconnect: YesRated Operating Current: [Ie] 32 A at 415 V AC 50/60 HzRated Operational Voltage [Ue]: 415 V AC 50/60 HzRated Insulation Voltage [Ui]: 500 V AC 50/60 Hz conforming to CEI EN 60669-2-4Rated Impulse Withstand Voltage [Uimp]: 4 kV Control type: LeverLocal signaling: ON/OFF indicationContact position signaling: YesInstallation: Fixed Installation Guide: DINpitch 9 mm4height77 mm width36 mmdepth70 mmColourWhiteMechanical durability300000 cycleselectrical life30000 cyclesconnections - terminalsCage terminals - 1 x 10 mm² - rigidCage terminals cage - 1 x 10 mm² - flexibleCage terminals - 2 x 10 mm² - flexible with ring nutwire stripping length9 mmTightening torque 1.2 Nm

    €51,96

  • ATV320U07N4C | Schneider Electric ATV320 speed variator

    SCHNEIDER ELECTRIC ATV320U07N4C | Schneider Electric ATV320 speed variator

    Schneider Electric ATV320 speed variator - 0.75kW - 380...500V - 3 phase - compact ATV320U07N4C The Altivar 320Schneider Electric speed variator is capable of powering 3-phase synchronous and asynchronous power motors with a nominal power of up to 0.75 kilowatts/1 horsepower and a nominal voltage of 380 to 500 Vac. This variable speed drive/frequency drive (VSD / VFD) is designed for simple industrial and commercial machines, such as packaging, material handling machinery, mechanical actuators and lifting devices. Its compact form factor allows you to reduce machine footprint by vertically stacking units in a machine frame. Advanced connectivity, including CANopen and Modbus, enables deep integration into automation architectures without the use of additional network equipment. Product Range: Altivar Machine ATV320Product Type: Variable speed driveProduct For Specific Applications: Complex MachinesVariant Version: standardDrive Format: CompactInstallation: Wall MountingPort Communication Protocol: Modbus serialCANopenNominal Power Voltage [Us]: 380...500 V - 15...10 %Nominal Output Current: 2, 3 A Technical characteristicsnumber of digital inputs7type of digital inputSTO safe torque off, 24 V DC, impedance: 1, 5 kOhmDI1...DI6 logic inputs, 24 V DC (30 V)DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)digital input logicPositive logic (source)Negative logic (current)number of digital outputs3type of digital outputOpen collector DQ+ 0…1 kHz 30 V DC 100 mAOpen collector DQ- 0…1 kHz 30 V DC 100 mAnumber of analog inputs3type of analog inputAI1 voltage: 0.. .10 V DC, impedance: 30 kOhm, 10 bit resolutionBipolar differential voltage AI2: +/- 10 V DC, impedance: 30 kOhm, 10 bit resolutionCurrent AI3: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other models for configuration), impedance: 250 Ohm, 10 bit resolutionnumber of analog outputs1type of analog outputCurrent configurable with AQ1 software: 0...20 mA impedance 800 Ohm, 10 bit resolutionVoltage configurable with AQ1 software: 0...10 V DC impedance 470 Ohm, 10 bit resolutionrelay output typeConfigurable relay logic R1A 1 NO electrical life 100000 cyclesConfigurable relay logic R1B 1 NC electrical life 100000 cyclesConfigurable relay logic R1CConfigurable relay logic R2A 1 NO electrical life 100000 cyclesConfigurable relay logic R2Cmaximum switching current: 3 A at 250 V AC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 3 A at 30 V DC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 2 A at 250 V AC on inductive load, cos phi = 0 ,4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 2 A at 30 V DC on inductive load, cos phi = 0.4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 5 A at 250 V AC on resistive load, cos phi = 1 R2A, R2C relay output: 5 A at 30V DC on resistive load, cos phi = 1 R2A, R2C relay outputminimum switching current: 5 mA at 24V DC R1A, R1B, R1C, R2A, R2C relay outputaccess method CANopen slave4 quadrant operation possibleTrueasynchronous motor control profileVoltage/frequency ratio, 5 pointsSensorless vector control, standardVoltage/frequency ratio - Energy saving, quadratic U/fSensorless vector control - Energy savingVoltage/frequency ratio, 2 pointsSynchronous motor control profileSensorless vector controltransient overtorque170…200 % of nominal motor torquemaximum output frequency0.599 kHzacceleration/deceleration rampsLinear USCUSRamp switchingAcceleration/deceleration ramp adaptationAutomatic acceleration/deceleration stop with DC injectionmotor slip compensationAny automatic loadAdjustable 0...300%Not available in voltage/frequency ratio (2 or 5 points)switching frequency2...16 adjustable kHz4...16 kHz with derating factornominal switching frequency4 kHzholding brakingWith injection DCIntegrated brake chopperTrueline current3.6 A at 380 V (heavy duty)2.8 A at 500 V (heavy duty)Maximum input current per phase3.6 AMaximum output voltage500 V apparent power2.4 kVA at 500 V (heavy duty)Mains frequency50...60 HzSymmetric relative mains frequency tolerance5 %Prospective line Isc5 kALoad current high-overload base7.1 Apower dissipation in W32.0 W fan: at 380 V, switching frequency 4 kHzWith function Safely Limited Speed ​​(SLS)TrueWith safety function Safe Brake Management (SBC/SBT)FalseWith safety function Safe Operating Stop (SOS)False With safety function Safe Position (SP)FalseWith safety function Safe Programmable LogicFalseWith safety function Safe Speed ​​Monitor (SSM)False With safety function Safe Stop 1 (SS1)TrueWith sft fct Safe Stop 2 (SS2)FalseWith safety function Safe Torque Off (STO)True With safety function Safe Limited Position (SLP)FalseWith safety function Safe Direction (SDI)Falsetype of protectionInterruption input phase: commandOvercurrent between output phases and earth : commandOverheating protection: commandShort circuit between phases of the motor: commandThermal protection: commandwidth105.0 mmheight 142.0 mmdepth158.0 mmproduct weight1.2 kg

    €342,33

  • ATV320U75N4B | Schneider-electric Speed ​​variator

    SCHNEIDER ELECTRIC ATV320U75N4B | Schneider-electric Speed ​​variator

    Schneider-electric Speed ​​variator ATV320U75N4B The Altivar 320 Schneider Electric variable speed drive is capable of powering 3-phase synchronous and asynchronous power motors with a nominal power of up to 7.5kilowatts/10 horsepower and a nominal voltage of 380 to 500Vac. This variable speed drive/frequency drive (VSD / VFD) is designed for simple industrial and commercial machines, such as packaging, material handling machinery, mechanical actuators and lifting devices. Its Book form factor helps reduce machine footprint, especially when mounted in an electrical cabinet next to other control devices such as PLCs, I/O units. Advanced connectivity, including CANopen and Modbus, enables deep integration into automation architectures without the use of additional networking equipment. Technical dataProduct rangeAltivar Machine ATV320Product typeVariable speedproduct for specific applicationsComplex machinesvariantStandard versionvariator formatBookInstallationWall mountport communication protocolSerial ModbusCANopenoption boardCommunication module, CANopenCommunication module , EtherCATCommunication module, Profibus DP V1Communication module, ProfinetCommunication module, Ethernet PowerlinkCommunication module, Ethernet/IPCommunication module, DeviceNetPower supply voltage nominal [Us]380...500 V - 15...10 %nominal output current17.0 Apower motor in kW7.5 kW for heavy dutyEMC filterClass C2 integrated EMC filterIP protection degreeIP20number of digital inputs7type of digital inputSTO safe torque off, 24 V DC, impedance: 1.5 kOhmDI1...DI6 logic inputs, 24 V DC (30 V)DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)digital input logicPositive logic (source)Negative logic (current)number of digital outputs3type of digital outputCollector open DQ+ 0…1 kHz 30 V DC 100 mAOpen collector DQ- 0…1 kHz 30 V DC 100 mAnumber of analogue inputs3type analog input voltageVoltage AI1: 0...10 V DC, impedance: 30 kOhm, resolution 10 bitBipolar differential voltage AI2: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bitAI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other models per configuration), impedance: 250 Ohm, 10 bit resolution number of analogue outputs1type of analogue outputCurrent configurable with AQ1 software: 0...20 mA impedance 800 Ohm, resolution 10 bitVoltage configurable with software AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bitrelay output typeConfigurable relay logic R1A 1 NO electrical life 100000 cyclesConfigurable relay logic R1B 1 NC electrical life 100000 cyclesConfigurable relay logic R1CConfigurable relay logic R2A 1 NO electrical life 100000 cyclesConfigurable relay logic R2Cmaximum switching current: 3 A at 250 V AC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 3 A at 30 V DC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 2 A at 250 V AC on inductive load, cos phi = 0.4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 2 A at 30 V DC on inductive load, cos phi = 0.4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 5 A at 250 V AC on resistive load, cos phi = 1 R2A, R2C relay output: 5 A at 30 V DC on resistive load , cos phi = 1 R2A, R2C relay outputminimum switching current: 5 mA at 24 V DC R1A, R1B, R1C, R2A, R2C relay outputaccess method Slave CANopen4 quadrant operation possibleTrueasynchronous motor control profileVoltage/frequency ratio, 5 pointsControl Sensorless Vector, StandardVoltage/Frequency Ratio - Energy Saving, Quadratic U/fSensorless Vector Control - Energy SavingVoltage/Frequency Ratio, 2 PointsMotor Control Profile synchronousVector control without sensortransient overtorque170…200 % of nominal motor torquemaximum output frequency0.599 kHzacceleration/deceleration rampsLinearUSCUSRamp switchingmotor slip compensationAny automatic load Adjustable 0...300%Not available in voltage/frequency ratio (2 or 5 points)switching frequency2...16 kHz adjustable4...16 kHz with derating factornominal switching frequency4 kHzholding brakingWith DC injection line current26.5 A at 380 V (heavy duty)18.7 A at 500 V (heavy duty)Maximum Input Current per phase26.5 AMaximum output voltage500 Vapparent power16.2 kVA at 500 V (use heavy)Mains frequency50...60 HzIsc prospective line22 kApower dissipated in W229.0 W fan: at 380 V, switching frequency 4 kHz With safety function Safely Limited Speed ​​(SLS)TrueWith safety function Safe Brake Management (SBC/SBT)False With safety function Safe Operating Stop (SOS)FalseWith safety function Safe Position (SP)FalseWith safety function Logic programmable safeFalseWith Safe Speed ​​Monitor (SSM) safety functionFalseWith Safe Stop 1 (SS1) safety functionTrueWith sft fct Safe Stop 2 (SS2)FalseWith Safe Torque Off (STO) safety functionTrue With safety function Safe Limited Position (SLP)FalseWith safety function Safe Direction (SDI)Falsetype of protectionInput phase interruption: commandOvercurrent between output phases and earth  : commandOverheating protection: commandShort circuit between motor phases: commandThermal protection: commandwidth150 mmheight308.0 mmdepth 232.0 mmproduct weight4.4 kg

    €1.031,16

  • ABL8RPS24050 | Schneider-Electric universal power supply

    SCHNEIDER ELECTRIC ABL8RPS24050 | Schneider-Electric universal power supply

    Schneider-Electric universal power supply ABL8RPS24050 The Schneider Electric ABL8 regulated switching mode power supply provides direct current voltage, has a rated input of 100 to 500 Vac, a rated output current of 5 A at 24 Vdc and a rated power of 120 watts. PresentationProduct rangeModicon Power SupplyProduct typePower supplypower supply type Switching modeNominal input voltage100...120 V AC single phase, terminals: N-L1200...500 V AC phase to phase, terminals: L1-L2rated power in W 120 Woutput voltage 24 V DCoutput power supply current 5 Aadmissible temporary current amplification 1.5 x In (for 4 s)anti-harmonic filterLow frequency harmonic currentsTechnical characteristicsinput voltage limits85...132 V AC170...550 V ACinput current inrush 30 A18 mm modules0.51 at 240 V AC0.59 at 120 V ACefficiency 87 %Output voltage adjustment24...28, 8 V adjustablepower dissipated in W 15.5 WEquipment suppliedCorrector filter power factor compliant with IEC 61000-3-2output protection type Against overload, protection technology: manual or automatic resetAgainst overvoltage, protection technology: 30...32 V, manual resetAgainst short circuits, protection technology: manual or automatic resetAgainst undervoltage, protection technology: intervention with U Thermal, protection technology: automatic resetConnections - terminalsRemovable screw terminal block: 2 x 2.5 mm², for diagnostic relayScrew terminal blocks: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connectionScrew terminal blocks: 1 x 0.5... 1 x 4 mm², (AWG 22...AWG 12) for input earth connectionScrew terminal blocks: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connectionScrew terminal blocks: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output grounding connectionStatus LED1 LED (green and red) output voltage1 LED (green, red and orange) output currentdepth125 mmheight143 mmwidth56 mm product weight0.7 kgoutput connectionParallelSeries

    €186,86

  • VW3A3608 | Schneider-electric CANopen communication module

    SCHNEIDER ELECTRIC VW3A3608 | Schneider-electric CANopen communication module

    Schneider-electric CANopen communication module  VW3A3608   The Altivar CANopen daisy chain communication module from Schneider Electric has 2 ports with RJ45 connectors. It complies with the CANopen Daisy Chain communication protocol. This communication module allows the integration of the drive into the CANopen daisy-chain process control network. Thanks to the removable modular design it is easy to install and remove from Altivar drives. It is compatible with Altivar Process ATV600 (ATV630, ATV650), Altivar Process ATV900 (ATV930, ATV950), Altivar Machine ATV320, Lexium 32, Altivar 32 and Altivar Machine ATV ATV340. Product rangeAltivarProduct typeCommunication moduleaccessories / element categoryAccessories communicationProduct compatibilityLexium 32Mrange compatibilityAltivar 32Altivar Machine ATV320Altivar Machine ATV340 except Sercos driveLexium 32Altivar Process ModularAltivar Process ATV900Altivar Process ATV600port communication protocolCANopen, CANmotionelectrical connection 2 RJ45 connectors

    €82,29

© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account