SCHNEIDER ELECTRIC POWER DISTRIBUTION

21 products

  • R9D60616 Interruttori magnetotermici differenziali

    SCHNEIDER ELECTRIC R9D60616 | Schneider Electric Residual current circuit breakers (RCBOs). Returns9. 1P+N. 16 A. curve C. 4500 A. 30 mA. AC type

    7 in stock

    Schneider Electric Residual current circuit breakers (RCBO), Resi9, 1P+N, 16 A, C curve, 4500 A, 30 mA, Type AC R9D60616 This Resi9 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole and 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. The earth leakage protection delay is instantaneous. The rated short-circuit breaking capacity Icn is up to 4500A according to EN/IEC 61009-2-1. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. It offers a reliable and safe solution for commercial and industrial applications with high breaking capacity. This product complies with IEC/EN 61009-2-1. It has an electrical resistance of up to 7500 cycles and a mechanical resistance of up to 20000 cycles. The EU operating voltage is 230 V AC. It can be installed on a DIN rail. Width in 9 mm steps is 4. The color of the product is white (RAL 9003). The dimensions are (W) 36mm x (H) 82mm x (D) 70.5mm. The weight is 186 g. It has an IP20 protection degree (according to the IEC/EN 60529 standard) which increases to IP40 if inserted in a modular cabinet. The operating temperature is between -25°C and -60 C. Technical dataRange"Resi9"Product name"Resi9 RCBO"Product typeDifferential magnetothermic switch (RCBO)Number of poles1P + Nneutral positionLeftnumber of protected poles1Rated current [In]16 AType of networkCARelease technologyMagnetothermalcode curveCdifferential sensitivity30 mAtiming differential protectionInstantaneoustype of differential protectionType ACInterrupting capacity4500 A compliant with CEI EN 61009-2-1 AC 50 Hzquality marksIMQFeatures techniquesdevice position in the systemStarting pointMains frequency50 HzRated operational voltage [Ue]230V AC 50 Hzmagnetic release limit5...10 x Indifferential technology"Voltage independent"Voltage insulation rating [Ui]400 VRated impulse withstand voltage [Uimp]4 kVpeak current250 Aposition signaling contactsYesType of controlLeverLocal signalingIndication ON/OFFInstallationHookupInstallationDIN railconnection pitch9 mm between phase e neutralpitch 9 mm4height82 mmwidth36 mmdepth70.5 mmproduct weight186 gColourWhiteDuration mechanical20000 cycleselectrical life7500 cyclesconnections - terminalsCage terminals (top or bottom) - 1...16 mm² - rigidCage terminals (top or bottom) - 1...10 mm² - flexibleCage terminals (top or bottom) - 1...10 mm² - flexible with ring nutwire stripping length13 mm for upper or lower part connectiontightening torque2 Nm upper or lower partprotection differentialIntegratedEnvironmentReference standardsCEI EN 61009-2-1CEI EN 61009-1degree of IP protectionIP20pollution degree2overvoltage categoryIIIAmbient temperature- 25…60 °C

    7 in stock

    €19,35

  • PAS800 | Schneider Electric EcoStruxure Panel Server

    SCHNEIDER ELECTRIC PAS800 | Schneider Electric EcoStruxure Panel Server

    Schneider Electric EcoStruxure Panel Server PAS800 - Advanced wireless and modbus datalogger, Energy Server, 110-277 VAC/DC Technical data Nominal supply voltage [Us]"110...277 V" AC 50/60 Hz"110...277 V" DCCommunication Gateway Ethernet TCP/IP to wireless devicesEthernet/serialPower Absorption In W 3.5 W "110...277 V"Type of Communication Network Ethernet, 10/100BASE-TWi-Fi"2.4 GHz"Wi-Fi"5 GHz"Wireless, "IEEE 802.15.4"Modbus RTU, Modbus RTU client odd/even or no parity, at "1.2...115.2 kbit/s "Modbus Communication Port Protocol TCPDHCPHTTPSNTP/SNTP"IPv4""IPv6"TCP/IPCommunication Port Protocol2 RJ45: EthernetScrew terminal block: RS485Number Of Server 32 slave(s)Modbus RTU - without repeater128 slave(s)Modbus RTU - with repeater128 slave(s)Modbus TCP40 slave(s)"IEEE 802.15.4"Memory Capacity "32 GB" "eMMC"512 MB NANDNumber of Inputs 0Connections - Terminals Power: screw terminal (top) 1.5…2.5 mm² cables Communication: screw terminal (bottom) 0.14…1.5 mm² cablesPair Tightening Power: 0.6 NmCommunication: 0.25 NmWire Stripping Length Power supply: 7 mmCommunication: 7 mmConnector type RP-SMA antennaInstallation CouplingInstallation DIN railProduct certifications CEcULusRCM"UKCA"FCCICReference Standards IEC 61010IEC 61010-1IEC 61010-2-201UL 61010UL 61010-1UL 61010-2-201"CSA C22.2 No 61010-1-12"CSA C22.2 No 61010-2-201"IEC 62974-1""IEC 62443-4-1"IEC 61326-1"EN 301-489-1""EN 301- 489-17"EN 301-893"EN 55032"CISPR 11"EN 300-328"IEEE 802.15.4"IEEE 802.11a/b/g/n"Depth 70.2 mmHeight 93 mmWidth 72 mmProduct Weight 206 g

    €889,50

  • LV429387 | Schneider Electric Sganciatore

    SCHNEIDER ELECTRIC LV429387 | Schneider Electric MX release - 208..277V 60 Hz. 220..240V 50/60 Hz

    Schneider Electric MX release - 208..277V 60 Hz, 220..240V 50/60 Hz LV429387 MX shunt coil for Compact NSX, PowerPact Multistandard and EasyPact CVS circuit breakers. The nominal voltage is between 220 and 240 Vac at 50/60 Hz, or between 208 and 277 Vac at 60 Hz. PresentationRangeComPacTProduct range"ComPact NSX100...250""ComPacT NSX100. ..250 new generation""ComPact NSX400...630""ComPacT NSX400...630 new generation""ComPact NSX100...250 DC""ComPacT NSX100...250 DC new generation"ComPact NSX100 ...250 DC PV"ComPacT NSX100...250 DC PV new generation""ComPact NSX400...630 DC""ComPacT NSX400...630 DC new generation"ComPact NSX400...630 DC PV"ComPacT NSX400...630 DC PV new generation"Device nameMXProduct typeRelease coilApplicationControlvoltage release typeOpening coilOpening coil releaseControl voltage [Uc]220...240 V AC 50/60 Hz208...277 V AC 60 HzRange compatibility"ComPacT new generation" "ComPacT NSX new generation""ComPacT new generation" "ComPacT NSX DC new generation"Compact Compact NSXCompact ComPact NSX DCEasypact "EasyPact CVS"PowerPact PowerPact MultistandardTechnical specificationsOperating threshold0.7...1.1 One openingresponse time50 mscontrol signal typePulseMaintainedpulse duration>= 20 msinrush voltage power supply10 VAAuxiliary terminal blockSpring 0.5…1.5 mm² (AWG 20...AWG 16)wire stripping length7 mm

    €118,30

  • LV434400 |<tc>Schneider Electric</tc>

    SCHNEIDER ELECTRIC LV434400 |Schneider Electric

    Schneider Electric LV434400  It is a 3-pole interrupter block for Compact NSX 160E circuit breaker designed to optimize space and interrupting capacity. It is an optimal choice for all standard and specific applications. It has a breaking capacity (Icu) of 16kA rms at 415VAC 50/60 Hz. The nominal current is 160A and the operating voltage is 690VAC 50/60Hz. Technical data Rated insulation voltage [Ui] 800 V AC 50/60 Hz compliant with IEC 60947-2 Rated impulse withstand voltage [uimp] 8 kV compliant with IEC 60947-2 Type of protection Without protection Width (W) 105mm Height (H) 161mm Depth (D) 86 mm

    €132,25

  • A9CR2225 SCHNEIDER ELECTRIC

    SCHNEIDER ELECTRIC A9CR2225 SCHNEIDER ELECTRIC

    RED automatic reset differential switch, 2P, 25A, 30mA, Type A. DIN rail mounting

    €169,40

  • LV426708 | Schneider-electric Circuit breaker

    SCHNEIDER ELECTRIC LV426708 | Schneider-electric Circuit breaker

    Schneider-electric Compact NSXm Vigi circuit breaker 160A 4P 16kA EverLink connector  LV426708 The LV426708 is a Compact NSXm residual current circuit breaker with Micrologic Vigi 4.1 control unit, 160 A, 16 kA at 415 VAC. It is designed for all standard LV applications. It provides integrated earth leakage protection for transformer-fed distribution systems. It features new features such as Everlink connector technology. It offers plate and DIN rail mounting capabilities and externally visible spring-loaded auxiliaries. This 4-pole integrated residual current circuit breaker (ELCB) is one of the smallest on the market. Dimensions: 108 mm (W) x 144 mm (H) x 80 mm (D). It ensures compliance with international standards (IEC 60947/CCC/EACH) and marine specifications. Technical dataRangeCompactProduct NameCompact NSXmProduct rangeCompact NSXmDevice Name"NSXm 160E"Product typeDifferential circuit breakerApplicationProtectionDistributionNumber of poles4Pprotected poles description"4D"neutral positionLeftRated current [In]160 A at 40 °CRated operational voltage [Ue]440VAC 50/60HzNetwork typeCANetwork frequency50/60 HzAptitude for sectioningYes compliant with EN/IEC 60947-2Category of useCategory A[Icu] rated ultimate short-circuit breaking capacity25 kA Icu compliant with IEC 60947-2 at 220...240 V AC 50/60 Hz16 kA Icu compliant with IEC 60947-2 at 380...415 V AC 50/60 Hz10 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 HzPerformance levelAnd 16 kA 415 V ACRelease Name"Micrologic 4.1"Release technologyElectronictrip unit protection functionsLSoIRControl typeLeverCircuit breaker mounting modeWith screwsHookupRated insulation voltage [Ui]500VAC 50/60HzRated impulse withstand voltage [Uimp]8kV[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA at 380...415 V AC 50/60 Hz compliant with IEC 60947-210 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Mechanical durability20000 cyclesElectrical life10000 cycles at 440V In20000 cycles at 440 V In/2InstallationPlateDIN railConnection terminals1 Everlink connector 2.5…70 mm², flexible copper1 Everlink connector 2.5…95 mm², rigid or stranded aluminum/copperConnection step35mm with diffusers27 mm Without spacers9mm steps12 moduletype of protectionL : for overload protection (thermal)"So": for short-time short-circuit protection with fixed delayI : for Instantaneous short circuit protectionR : for earth leakage protectionRelease gauge160 A at 40 °Cthermal memory20 minutes before and after the shotdifferential protectionIntegratedEarth-leakage protection sensitivity adjustment type IΔnAdjustable[IΔn] earth-leakage protection sensitivity adjustment range0.03…5 ADifferential Sensitivity30 mA for class A100 mA for class A300 mA for class A500 mA for class A1000 mA for class A30 mA for AC class100 mA for AC class300 mA for AC class500 mA for AC class1000 mA for AC class3000 mA for AC class5000 mA for AC classEarth leakage protection delay adjustment type Δt Adjustable[Dt] Erth-loss prefix price delay adjustment interval 0 ms60 ms150 ms500 ms1000 msSecurity SettingsNo protection1 x Ir0.5 x IrNumber of slots for electrical auxiliaries1 slot for OF auxiliary contact1 SD alarm contact slot1 "MN or MX" opening coil slotlocal reportingLED flashing (green) ready for operation:LED 105% Ir (red)Overload:LED 90% Ir (orange)Overload:Length108mmHeight144mmDepth80mmProduct weight1.63 kgColorGrey (RAL 7016)

    €996,30

  • a9a26946

    SCHNEIDER ELECTRIC A9A26946 | Schneider-Electric Release current launch

     Schneider-Electric Release. current throw iMX+OF 110/415Vac 110/130Vcc A9A26946 This Acti9 iMX+OF auxiliary electrical release for is a shunt release device with open/closed auxiliary contact. It is dedicated to Acti9 iC60, iID, iDPN Vigi, iSW-NA. This device includes an OF open/closed contact to indicate the location of the paired device. Presentationrange of productActi9Product typeRelease coil with open/closed contactDevice nameiMX+OFsignal contact composition1 A/CRated current [In]AC-12 3 A at 415 V , AC 50 HzAC-12 6 A at 100 V, AC 50 HzAC-12 6 A at 230 V, AC 50 HzDC-12 1 A at 110 V, DC DC-12 1 A at 130 V, DCControl voltage [Uc]100...415 V AC 50/60 Hz110...130 V DC9 mm pitch 2Technical characteristicsRange compatibilityActi9 -Acti9 Acti9 ARAActi9 -Acti9 Acti9 iIDActi9 Acti9 iSW -NAActi9 Acti9 RCAActi9 Acti9 iDPN (China version)Acti9 Acti9 iC60 two-terminal thermomagnetic switchActi9 Acti9 iC40Local signalingIndicator actionInstallationHookupInstallationDIN raildistribution comb compatibilityTop part: YESwidth18 mm ColorWhiteconnections - terminalsClip terminal - 2 cables 2.5 mm² - flexible with cable terminationClip terminal - 1 cable 6 mm² - rigidClip terminal - 2 cables 2.5 mm² - rigidClip terminal - 1 cable 4 mm² - flexibletightening torque 1 NmCompatibility codeIMX+OFEnvironmentReference standardsCEI EN 60947-5-1tropicalization2 compliant with CEI EN 60947-5-1relative humidity95 % at 55 °CAmbient temperature-25…50 °CStorage temperature-40…85 °C

    €43,55

  • A9Q41425 | Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block

    SCHNEIDER ELECTRIC A9Q41425 | Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block

    Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block A9Q41425 Acti9 Vigi iC60 is a modular additional residual current device. It is a 4P, rated current of 25A, operating voltage from 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 30 mA and voltage independent technology. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. A VisiTrip window is here to indicate a fault trip via a red mechanical indicator on the front. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of people and protection of installations. This product complies with IEC 61009-1 and EN 61009-1. The nominal operating voltage Ue is 400 V AC. The rated insulation voltage Ui is 500 V AC. The rated impulse withstand voltage Uimp is 6 kV. The pollution degree is 3. It can be mounted on DIN rail. Width in 9mm steps is 6. Dimensions are (W) 54mm x (H) 91mm x (D) 73.5mm. The weight is 0.245 kg. The degree of protection is IP20 and IP40 in a cabinet. The operating temperature is between -5°C and +60°C. The storage temperature is between -40°C and +85°C. Technical dataRangeActi9Product typeResidual current add-on devicesDevice nameVigi iC60Number of poles4PRated current [In]25 Adifferential sensitivity30 mAtiming differential protectionInstantEarth leakage protection typeAC typeNetwork type ACMains frequency50/60 HzRated operational voltage [Ue]400 V AC 50/ 60 Hz conforming to EN 61009-1400/415 V AC 50/60 Hz conforming to IEC 61009-1conforming to IEC/EN 61009-2-1Reference standardsIEC 61009-1EN 61009-1pitch 9 mm6device position in the systemStarting point residual current release technology"Voltage independent"Rated insulation voltage [Ui]500 V AC 50/60 Hz compliant with IEC 60947-2Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2Gamma compatibilityActi9 Acti9 iC60 Acti9 Acti9 Reflex iC60Product compatibilitySingle terminalLocal signalingTrip indicatorInstallationHookupInstallationDIN railelectrical connection to the circuit breakerPlug incomb compatibility distributionLower part: YESheight91 mmwidth54 mmdepth73.5 mmproduct weight0.245 kgconnections - terminalsBottom side cage terminal for 1 cable 1… 25 mm² rigid without cable endBottom side cage terminal for 1 cable 1…16 mm² flexible without cable endBottom side cage terminal for 1 cable 1…16 mm² flexible with cable end wire stripping length14 mm for lower part connectiontightening torque2 Nm lower part

    €188,35

  • A9P54610 | Schneider-electric iC40N 1P+N C 10A 6000A circuit breaker

    SCHNEIDER ELECTRIC A9P54610 | Schneider-electric iC40N 1P+N C 10A 6000A circuit breaker

    Schneider-electric Circuit breaker iC40N 1P+N C 10A 6000A A9P54610 This Acti9 iC40N product is a low voltage circuit breaker (MCB). It is a 1P+N switch with 1 protected pole and 10A rated current In and tripping curve C. The rated short-circuit breaking capacity reaches up to 10kA at 230VAC in compliance with the EN/IEC 60947-2 standard and 6000A at 230VAC in compliance with EN/IEC 60898-1. This product complies with industrial standards EN/IEC 60898-1 and residential standards EN/IEC 60947-2. This circuit breaker combines the functions of circuit protection against short circuits and overload current, control and isolation. Installation and wiring are simplified with clip-on functionality and easy maintenance. Technical dataRangeActi9Product nameActi9 iC40Product typeSwitch modularDevice nameiC40NApplicationDistributionNumber of poles1P + Nnumber of protected poles1neutral positionLeftRated current [In]10 AType of networkCARelease technologyMagnetothermalcurve codeCSwitching capacity10 kA Icu compliant with EN/IEC 60947-2 at 230 V AC 50/60 Hz6000 A Icn compliant with CEI EN 60898-1 at 230 V AC 50/60 Hz Aptitude for sectioningComplies with EN/IEC 60947-2quality marksAENOROVEIMQ RCMTechnical characteristicsMains frequency50/60 HzRated operational voltage [Ue]230 V AC 50/60 Hzmagnetic release limit5...10 x In conforming to CEI EN 60898-18 x In +/- 20 % conforming to EN/IEC 60947-2 Rated service breaking capacity [Ics]6000 A 100 % Icn at 230 V AC 50/60 Hz compliant with CEI EN 60898-17.5 kA 75 % Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2limitation class3 conforming to CEI EN 60898-1Rated insulation voltage [Ui]400 V AC 50/60 Hz conforming to EN/IEC 60947-2Rated impulse withstand voltage [Uimp]4 kV conforming to EN /IEC 60947-2contact position signalingYesType of controlLeverLocal signalingON/OFF indicationSnap indicatorInstallationAttachmentInstallationDIN rail9 mm pitch2height85 mmwidth18 mmdepth74 mm product weight120 gColorWhiteMechanical durability20000 cycleselectrical life20000 cyclesDescription of locking optionsPadlock deviceconnections - terminalsTop part cage terminals or lower1…10 mm² flexibleCage terminals upper or lower part1…16 mm² rigidwire stripping length14 mm for upper or lower part connectionpair tightening pressure2 Nm upper or lower partdifferential protectionSeparate block  

    €46,05

  • METSEPM5110 | Schneider Electric PM5110 power meter 96x96

    SCHNEIDER ELECTRIC METSEPM5110 | Schneider Electric PM5110 power meter 96x96

    Schneider Electric PM5110 power meter 96x96 METSEPM5110 The device is a flush mount energy meter with a 96mm x 96mm backlit LCD display. The meter ensures 0.5S accuracy class according to IEC 62053-22 and 64 samples per cycle. The device measures energy, active and reactive power, voltage, current, frequency, power factor and up to the 15th harmonic. The meter operates on a 50 or 60 Hz mains and accepts supply voltages of 100 to 415 V AC and 125 to 250 V DC. The rated line current for this meter is 1A or 5A input and supports single-phase and neutral, three-phase, or three-phase and neutral configurations. The measurement voltage range between phases is 35 to 690 V AC, 47 to 63 Hz. The measurement range between phase and neutral is 20 to 400VAC, 47 to 63 Hz. The communication protocol consists of by Modbus RTU and ASCII 2 cables with RS485 port. The meter also features a digital pulse output and 33 configurable alarms. Product Dimensions: Width 3.78 inches (96 mm), Depth 2.83 inches (72 mm), Height 3.78 inches (96 mm); weight 13.4 oz (380 g). Technical dataRangePowerLogicProduct namePowerLogic PM5000Device name PM5110Product typeMeasuring instrumentTechnical characteristicspower quality analysisUp to the 15th harmonicApplicationEnergy monitoringtype of measurementCurrentVoltageFrequencyPower factorEnergyActive and reactive powersupply voltage90...450 V AC 45...65 Hz100 ...300 V DCMains frequency50 Hz60 HzRated current [In]1 A 5 Atype of network1P + N3P + N3Ppower absorbed in VA11 VA at 415 Vlocal signaling80 ms 120 V AC typical100 ms 230 V AC typical100 ms 415 V AC typical50 ms 125 V DC typicaldisplay typeMonochrome graphic LCDdisplay resolution128 x 128sampling rate64 samples/ cyclecurrent measurement50…8500 mAanalog input typeVoltage (impedance 5 MOhm)Current (impedance measurement voltage35…760 V AC 45...65 Hz between phase and phase20…440 V AC 45...65 Hz between phase and neutralfrequency measurement range45…65 Hznumber of inputs0measurement precision Active energy +/- 0.5%Reactive energy +/- 2%Active power +/- 0.5%Apparent power +/- 0.5%Frequency +/- 0.05%Power factor +/- 0.5Current +/- 0.5%Voltage +/- 0.5%Apparent energy +/- 0.5 %Reactive power +/- 2%precision classClass 0.5S active energy compliant with IEC 62053-22number of outputs1 digitalcommunication port protocolModbus RTU and ASCII at 9.6 - 19.2 - 38.4 kbaud odd/even or none - 2 wires, 2500 V insulationJBUScommunication port protocolRS485data loggingTime indicationMin/max of instantaneous valuesconnections - terminalsVoltage circuit: screw terminal4Control circuit: screw terminal2 Currenttransformer: screw terminal6I/O circuit: screw terminal6RS485 connection: screw terminal4InstallationBuilt-insupport assemblyStructureReference standardsUL 61010-1CEI EN 50470-3CEI EN 50470-1IEC 62053-22 :2020IEC 60529IEC 62053-24IEC 61557-12:2015IEC 62053-23:2020IEC 62052-11:2020IEC 62052-3 1:2015 Product certificationsCE conforming to IEC 61010-1CULus conforming to UL 61010-1width96 mmdepth72 mmheight96 mmproduct weight380 g

    €529,20

  • A9DE3616 | Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC

    SCHNEIDER ELECTRIC A9DE3616 | Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC

    Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC A9DE3616 This Acti9 iCV40 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole, 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. PresentationRangeActi9Product nameActi9 iCV40Product typeThermal circuit breaker differential (RCBO)Device nameiCV40NApplicationDistributionNumber of poles1P + Nnumber of protected poles 1 neutral position LeftRated current [In] 16 AType of AC networkRelease technologyMagnetothermalcurve code Cdifferential sensitivity30 mADifferential protection timingInstantaneoustype of differential protectionAC typeInterrupting capacity6000 A Icn compliant with CEI EN 61009- 2-1 at 230 V AC 50/60 HzSuitable for isolationComplies with EN/IEC 60947-2quality marksIMQ"EAC" VDETechnical characteristicsComplementaryStarting pointMains frequency50/60 HzRated operational voltage [Ue ]230 V AC 50/60 Hzmagnetic trip limit5...10 x InResidual current trip technology"Independent from the voltage"Rated service breaking capacity [Ics]6000 A 100 % Icn at 230 V AC 50/60 Hz compliant with CEI EN 61009-2-1rated breaking and making capacityIdm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1limiting class3 compliant with CEI EN 61009-2-1Rated insulation voltage [Ui]400 ​​V AC 50/60 HzRated impulse withstand voltage [Uimp] 4 kVcontact position signaling YesType of control LeverLocal signalingFault indicationON/OFF indicationInstallationCouplingInstallationDIN raildistribution comb compatibilityUpper or lower part: toothconnection pitch9 mm between phase and neutralpitch 9 mm 4height 85 mmwidth 36 mmdepth 73 mmproduct weight 210 gColor White

    €146,70

  • A9S60232 | Schneider Electric iSW 2P 32A disconnect switch

    SCHNEIDER ELECTRIC A9S60232 | Schneider Electric iSW 2P 32A disconnect switch

    Schneider Electric  iSW 2P 32A disconnect switch A9S60232 This Acti9 iSW is a modular and reliable disconnector. It is a 2P, with a rated current of 32 A and an operating voltage of 415 V AC. The electrical resistance reaches up to 30000 cycles and the mechanical resistance reaches up to 300000 cycles. The operating temperature ranges from -20°C to +50°C. PresentationRangeActi9Product nameActi9 iSWProduct typeSwitch operating-disconnectorDevice nameiSWApplicationControlNumber of poles2PUsage categoryAC- 22ASuspension suitabilityYesTechnical characteristicsRated operational current [Ie]32 A at 415 V AC 50/60 HzRated operational voltage [Ue]415 V AC 50/60 HzRated insulation voltage [Ui]500 V AC 50 /60 Hz compliant with CEI EN 60669-2-4Rated impulse withstand voltage [Uimp]4 kVType of control LeverLocal signalingON/OFF indicationcontact position signalingYesInstallationFixedInstallation DIN railpitch 9 mm2height77 mmwidth18 mmdepth70 mmColorWhiteMechanical life300000 cycleslife electrical30000 cyclesconnections - terminalsCage terminals - 10 mm² - rigidCage terminals - 10 mm² - flexibleCage terminals - 10 mm² - flexible with ring nutwire stripping length9 mmTightening torque1.2 NmEnvironmentReference standards CEI EN 60669-2-4degree of protection IPIP4degree of pollution2tropicalization2relative humidity95% at 55 °C Ambient temperature-20…50 °CStorage temperature-40…70 °C

    €25,15

© 2024 DMSTECHMART, Powered by Shopify

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account