Description
Schneider-Electric safety module UAK 24V M.SCREW XPSUAK12AP
The product is part of the XPS Universal security module range. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP and NPN sensors, RFID safety switches, safety barriers and sensitive mats/edges.
Presentation
Product range
Harmony Safety Automation
Product type
Safety module
safety module name
XPSUAK
safety module application
Monitored antivalent contacts
For emergency, protection and barrier monitoring
4-wire pressure sensor monitoring
Module function
Emergency stop button with 2 NC contacts
Safety monitoring with 1 or 2 limit switches
Control of 2 PNP sensors
Magnetic switch monitoring
Safety barrier control
RFID safety switch control
Safety barrier monitoring (ESPE)
Safety mat control
Proximity sensor monitoring
Monitoring 1 PNP + 1 NPN sensor
Safety level
Can reach PL e/category 4 for NO relay contact conforming to ISO 13849-1
Can reach SILCL 3 for NO relay contact conforming to IEC 62061
Can reach SIL 3 for NO relay contact conforming to IEC 61508
Can reach PL c/category 1 for NC relay contact conforming to ISO 13849-1
Can reach SILCL 1 for NC relay contact conforming to IEC 62061
Can ' achieve SIL1 for NC relay contact conforming to IEC 61508
Reliability data safety
MTTFd > 30 years conforming to ISO 13849-1
Dcavg >= 99 % conforming to ISO 13849-1
PFHd = 1.13E-09 conforming to ISO 13849-1
HFT = 1 conforming to IEC 62061
PFHd = 1.13E-09 conforming to IEC 62061
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 1.13E-09 conforming to IEC 61508-1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
topology of the network
NC double
PNP double
Antivalent double OSSD double
connections - terminals
Removable screw terminal block, 0.2...2.5 mm² solid or flexible
Terminal block removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor
Removable screw terminal block, 0.2...1.5 mm² solid or flexible double conductor
Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with mask
Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with mask
Voltage nominal power supply [Us]
24 V AC - 15...10 %
24 V DC - 20...20 %
Technical characteristics
synchronization time between inputs 0.5 s 2 s 4 s
Type of starting
Automatic/manual/monitored
Power absorbed in W
2.0 W 24 V DC
Power consumption in VA
5.0 VA 24 V AC 50/60 Hz
type of input protection
Internal, electronic
safety outputs
2 NO + 1 NC
safety inputs
2 safety input 24 V DC 5 mA
maximum wire resistance
500 Ohm
Input compatibility
Normally closed circuit conforming to ISO 14119
XC limit switch conforming to ISO 14119
Mechanical contact conforming to ISO 14119
Normally closed circuit conforming to ISO 13850
Double antivalent conforming to ISO 14119
Double OSSD conforming to IEC 61496-1-2
3-wire PNP proximity sensors
Rated operational current [Ie]
5 A AC-1 for NO relay contact
3 A AC-15 for NO relay contact
5 A DC-1 for NO relay contact
3 A DC-13 for NO relay contact
3 A AC-1 for NC relay contact
1 A AC-15 for NC relay contact
3 A DC-1 for NC relay contact
1 A DC-13 for NC relay contact
control outputs
3 configurable on/off pulsed output
input/output type
Pulsed semiconductor signaling output. 24 V DC, 20 mA Z1, non-safety related
Conventional thermal current in air [Ith]
8 A
associated fuse rating
10 A gG for output circuit NO relay conforming to IEC 60947-1
minimum output current
10 mA per relay output
minimum output voltage
12 V per relay output
Rated insulation voltage [Ui]250 V (pollution degree 2) conforming to IEC 60947-1
Rated impulse withstand voltage [Uimp]
4 kV overvoltage category II conforming to IEC 60947-1
Installation
35 mm symmetrical DIN rail
depth
120 mm
height
100 mm
width
22.5 mm
product weight
0.200 kg