POWER DISTRIBUTION

108 products

  • magnetotermico differenziale 16a - 5SV13131KK16

    SIEMENS 5SV13131KK16 | Siemens Differential circuit breaker 16a

    SIEMENS RCBO 16a MTD 1P+N 1UM 4.5KA TYPE AC 30MA C16                            5SV13131KK16  Compact residual current circuit breaker 1P+N 4.5 kA type AC 30 mA C16. The differential switch is the fault current protection device against accidental contacts. Number of protected poles: 1Rated current: 16 ARated fault current: 0.03 AType differential: ACWith neutral: yesNumber of poles (total) : 2Rated voltage: 230 VRated insulation voltage Ui: 253 VRated impulse voltage resistance Uimp: 4 kVLimiting class: 3Rated breaking capacity according to EN 61009: 4.5 kARated breaking capacity according to IEC 60947-2: 5 kARated short-circuit breaking capacity according to EN 61009-1: 4.5 kASwitch-off characteristics: Non-delayedType voltage: ACTripping characteristic: CWith locking device: yesOvervoltage category: 3Pollution degree: 2Ambient temperature during operation: -25.. .45 °CWidth in number of modules: 1Recessing depth: 70 mmRecess-mountable: yesProtection against unexpected start-up: yesDegree of protection (IP): IP20Connectable single-wire (rigid) conductor section: 0.75...16 mm²Connectable multi-wire (semi-rigid) conductor section: 0.75...16 mm²

    €21,95

  • 131182300000 | Finder call/reset relay din 17.5mm 1co

    FINDER 131182300000 | Finder call/reset relay din 17.5mm 1co

    Finder call/reset relay din 17.5mm 1co 131182300000 Bistable call relay with reset command, changeover contact. Bistable operation with reset command particularly suitable for applications in the tertiary sector - public bathrooms, hospitals, hotels.Mounting on 5 mm bar Width 17.5 mm Features: Bistable operation with reset command particularly suitable for applications in the tertiary sector: public bathrooms, hospitals, hotels Mounting on 35 mm rail (EN 60715) or panel Contact configuration: 1 Exchange Nominal contact current: 12 A Dimensions: 17.5x84x56.5 mm Nominal /voltage: 230 V Nominal contact voltage: 250 V AC

    €45,60

  • 7P2782750020 | Finder surge arrester

    FINDER 7P2782750020 | Finder surge arrester

    Finder surge arrester 7P2782750020 7P.27 Type 2 surge arrester (2 varistors) for single-phase TN systems with Neutral with L, N-PE varistor protection and replaceable varistor modules.Available with remote contact for signaling the status of the varistor. Features: Suitable for AC and DC systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of the status of the varistor - working/to be replaced Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Varistor and spark gap modules, replaceable Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715), 17.5 mm per pole

    €72,95

  • 7M2482300210 Finder contatore di energia monofase

    FINDER 7M2482300210 | Finder bidirectional single-phase energy meter with LCD display

    Finder bidirectional single-phase energy meter with LCD display 7M2482300210 The bidirectional single-phase energy meters with LCD display Type 7M.24.8.230.0001, Type 7M.24.8.230.0010, Type 7M.24.8.230.0210 and Type 7M.24.8.230.0310 are the ideal solution for monitoring domestic consumption/ industrial and specifically can be used in offices, for photovoltaic systems and for energy metering in campsites. They are programmable via smartphone thanks to NFC technology, which allows you to read the measured energy even in the absence of the mains. They are also distinguished by the touch navigation and programming button and the power and control terminals with integrated anti-theft lock. Other features: 4 MID certified meters for imported and exported active and reactive energy 8 resettable counters for active, reactive, apparent absolute, imported and exported energy Extensive measurements available: V, I, Pf, f, THD of voltage and current and operating time for preventive maintenance activities Mbus and Modbus RS485 communication protocol Technical data: Type of meter: ElectronicRated current (In): 5 AMaximum current (Imax): 40 A Nominal voltage (Un) N-L: 230...230 VFrequency: 50...60 Hz Accuracy class: BPolarity type: Single phaseModel: Direct measurement Type of energy measured: Active and reactive powerPulse output: NoneType of indication: Digital Mounting method: DIN RailWidth in number of modules: 1 Interface type: ModbusNumber of digits: 7 Protection degree (IP): IP50

    €85,60

  • 7M2482300110 Contatore di energia monofase

    FINDER 7M2482300110 | Finder Bidirectional single-phase energy meter

    1 in stock

    Finder Bidirectional single-phase energy meter  7M2482300110 The bidirectional single-phase energy meters with LCD display Type 7M.24.8.230.0001, Type 7M.24.8.230.0010, Type 7M.24.8.230.0210 and Type 7M.24.8.230.0310 are the ideal solution for monitoring domestic consumption/ industrial and specifically can be used in offices, for example photovoltaic systems and for energy metering in campsites. They can be programmed via smartphone thanks to NFC technology, which allows you to read the measured energy even in the absence of the mains. They are also distinguished by the touch navigation and programming button and the power and control terminals with integrated anti-theft lock. Technical specifications:Type of meterElectronicRated current (In)5 AMaximum current (Imax)40 ANominal voltage (Un) N-L230...230 VFrequency50...60 HzPrecision classBType of polaritySingle phaseModelDirect measurementType of energy measuredActive power e reactiveCertifiedNationalPulse outputElectricPulse typeS0Pulse output frequency1000...1000 Imp/kWh (kKind of indicationDigitalMounting methodDIN railWidth in number of modules1Interface typeOthersNumber of digits7Degree of protection (IP)IP50

    1 in stock

    €67,45

  • 223400244320 | Finder 25 A modular contactor

    FINDER 223400244320 | Finder 25 A modular contactor

    Finder modular contactor 25 A 223400244320 Modular contactor 25 A - 4 contacts, 35mm width and a NO contact opening ≥ 3 mm, double break. Type 22.34 complies with EN 61095: 2009 Technical description: Modular contactor, 25 A, 4 contacts, NO, 25 A, AgSnO2, AC/DC coil, 24 V, operation from 19.2 to 26.4 V (AC)/( DC), rated power 2 VA (AC) / 2.2 W (DC), holding voltage 9.6 V (AC)/(DC), release voltage 2.4 V (AC)/(DC), variant: Mechanical indicator + LED, ambient temperature from -25 to +50 °C

    €37,25

  • 223200124520 | Finder modular contactor

    FINDER 223200124520 | Finder modular contactor

    Finder modular contactor 223200124520 Modular contactor 25 A, 2 contacts, 17.5mm width, NO contact opening ≥ 3 mm, double break. Suitable for railway applications; plastic materials compliant with fire and smoke regulations (EN 45545-2 + A1: 2016). Technical description:  Modular contactor, 25 A, 2 contacts, 1 NO + 1 NC, 25 A, AgSnO2, AC/DC coil, 12 V, operation from 9.6 to 13.2 V (AC)/(DC), rated power 2 VA (AC) / 2.2 W (DC), hold voltage 4.8 V (AC)/(DC), release voltage 1.2 V (AC)/(DC), variant: Mechanical indicator + LED, ambient temperature from -25 at +50 °C.  

    €26,35

  • 223200124340 | Finder Modular contactor

    FINDER 223200124340 | Finder Modular contactor

    Finder Modular contactor 223200124340 25 A modular contactor, 2 contacts, 17.5mm width, NO contact opening ≥ 3 mm, double break. Suitable for railway applications; plastic materials compliant with fire and smoke regulations (EN 45545-2 + A1: 2016). Technical description: Modular contactor, 25 A, 2 contacts, NO, 25 A, AgSnO2, AC/DC coil, 12 V, operation from 9.6 to 13.2 V (AC)/(DC), rated power 2 VA (AC ) / 2.2 W (DC), hold voltage 4.8 V (AC)/(DC), release voltage 1.2 V (AC)/(DC), variant: Manual selector + mechanical indicator + LED, ambient temperature -25 to +50 °C.

    €29,65

  • 2CDS252001R0324 | Abb S202-C32

    ABB 2CDS252001R0324 | Abb S202-C32

    4 in stock

      Abb  Miniature circuit breaker - 2P - C - 32 A 2CDS252001R0324 System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. Technical dataReference standards:IEC/EN 60898-1IEC/EN 60947-2UL 107 Tripping characteristic: C Rated operating voltage:according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 440 V ACOperating voltage:Maximum (Incl . Tolerance) 125 V DCMaximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kV Dielectric test voltage:50/60 Hz, 1 min: 2 kVInput voltage type:AC/DCRated current (In):32 A Rated short-circuit capacity: (AC) 6 kA(DC) 6 kA(400 V AC) 6 kA(400 V) 6 kA Rated extreme short-circuit capacity (Icu): (125 V DC) 10 kA(230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kA(48 V DC ) 20 kA(230 V) 20 kA(400 V) 10 kA Rated conditional short-circuit current (Inc): (230 V) 20 kA(400 V) 20 kARated service short-circuit capacity (Ics):(230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kAFrequency (f):50 HzRated frequency (f):50 / 60 Hz50 ... 60 Hz Power loss: 7.4 Wa Nominal Operating Conditions for Polo 3.7 WSupply voltage connection:ArbitraryContact position indication:Red ON / Green OFF Energy limitation class: 3   Electrical resistance:10000 AC cycle (i)Mechanical resistance:20000 cycle (i)Number of protected poles:2Number of poles:2Overvoltage category: IIITightening torque:2.8 N mMounting type:DIN-RailScrew terminal type:Failsafe Bi-directional Cylinder-lift TerminalActuator labeling:I / OActuator material:Insulation Group II, Black, SealableCasing material:Insulation class II, RAL 7035DIN rail mounting:TH35-15 (35 x 15 mm Mounting Bar) according to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Bar) according to IEC 60715

    4 in stock

    €23,05

  • R9D60616 Interruttori magnetotermici differenziali

    SCHNEIDER ELECTRIC R9D60616 | Schneider Electric Residual current circuit breakers (RCBOs). Returns9. 1P+N. 16 A. curve C. 4500 A. 30 mA. AC type

    7 in stock

    Schneider Electric Residual current circuit breakers (RCBO), Resi9, 1P+N, 16 A, C curve, 4500 A, 30 mA, Type AC R9D60616 This Resi9 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole and 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. The earth leakage protection delay is instantaneous. The rated short-circuit breaking capacity Icn is up to 4500A according to EN/IEC 61009-2-1. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. It offers a reliable and safe solution for commercial and industrial applications with high breaking capacity. This product complies with IEC/EN 61009-2-1. It has an electrical resistance of up to 7500 cycles and a mechanical resistance of up to 20000 cycles. The EU operating voltage is 230 V AC. It can be installed on a DIN rail. Width in 9 mm steps is 4. The color of the product is white (RAL 9003). The dimensions are (W) 36mm x (H) 82mm x (D) 70.5mm. The weight is 186 g. It has an IP20 protection degree (according to the IEC/EN 60529 standard) which increases to IP40 if inserted in a modular cabinet. The operating temperature is between -25°C and -60 C. Technical dataRange"Resi9"Product name"Resi9 RCBO"Product typeDifferential magnetothermic switch (RCBO)Number of poles1P + Nneutral positionLeftnumber of protected poles1Rated current [In]16 AType of networkCARelease technologyMagnetothermalcode curveCdifferential sensitivity30 mAtiming differential protectionInstantaneoustype of differential protectionType ACInterrupting capacity4500 A compliant with CEI EN 61009-2-1 AC 50 Hzquality marksIMQFeatures techniquesdevice position in the systemStarting pointMains frequency50 HzRated operational voltage [Ue]230V AC 50 Hzmagnetic release limit5...10 x Indifferential technology"Voltage independent"Voltage insulation rating [Ui]400 VRated impulse withstand voltage [Uimp]4 kVpeak current250 Aposition signaling contactsYesType of controlLeverLocal signalingIndication ON/OFFInstallationHookupInstallationDIN railconnection pitch9 mm between phase e neutralpitch 9 mm4height82 mmwidth36 mmdepth70.5 mmproduct weight186 gColourWhiteDuration mechanical20000 cycleselectrical life7500 cyclesconnections - terminalsCage terminals (top or bottom) - 1...16 mm² - rigidCage terminals (top or bottom) - 1...10 mm² - flexibleCage terminals (top or bottom) - 1...10 mm² - flexible with ring nutwire stripping length13 mm for upper or lower part connectiontightening torque2 Nm upper or lower partprotection differentialIntegratedEnvironmentReference standardsCEI EN 61009-2-1CEI EN 61009-1degree of IP protectionIP20pollution degree2overvoltage categoryIIIAmbient temperature- 25…60 °C

    7 in stock

    €19,35

  • PAS800 | Schneider Electric EcoStruxure Panel Server

    SCHNEIDER ELECTRIC PAS800 | Schneider Electric EcoStruxure Panel Server

    Schneider Electric EcoStruxure Panel Server PAS800 - Advanced wireless and modbus datalogger, Energy Server, 110-277 VAC/DC Technical data Nominal supply voltage [Us]"110...277 V" AC 50/60 Hz"110...277 V" DCCommunication Gateway Ethernet TCP/IP to wireless devicesEthernet/serialPower Absorption In W 3.5 W "110...277 V"Type of Communication Network Ethernet, 10/100BASE-TWi-Fi"2.4 GHz"Wi-Fi"5 GHz"Wireless, "IEEE 802.15.4"Modbus RTU, Modbus RTU client odd/even or no parity, at "1.2...115.2 kbit/s "Modbus Communication Port Protocol TCPDHCPHTTPSNTP/SNTP"IPv4""IPv6"TCP/IPCommunication Port Protocol2 RJ45: EthernetScrew terminal block: RS485Number Of Server 32 slave(s)Modbus RTU - without repeater128 slave(s)Modbus RTU - with repeater128 slave(s)Modbus TCP40 slave(s)"IEEE 802.15.4"Memory Capacity "32 GB" "eMMC"512 MB NANDNumber of Inputs 0Connections - Terminals Power: screw terminal (top) 1.5…2.5 mm² cables Communication: screw terminal (bottom) 0.14…1.5 mm² cablesPair Tightening Power: 0.6 NmCommunication: 0.25 NmWire Stripping Length Power supply: 7 mmCommunication: 7 mmConnector type RP-SMA antennaInstallation CouplingInstallation DIN railProduct certifications CEcULusRCM"UKCA"FCCICReference Standards IEC 61010IEC 61010-1IEC 61010-2-201UL 61010UL 61010-1UL 61010-2-201"CSA C22.2 No 61010-1-12"CSA C22.2 No 61010-2-201"IEC 62974-1""IEC 62443-4-1"IEC 61326-1"EN 301-489-1""EN 301- 489-17"EN 301-893"EN 55032"CISPR 11"EN 300-328"IEEE 802.15.4"IEEE 802.11a/b/g/n"Depth 70.2 mmHeight 93 mmWidth 72 mmProduct Weight 206 g

    €889,50

  • LV429387 | Schneider Electric Sganciatore

    SCHNEIDER ELECTRIC LV429387 | Schneider Electric MX release - 208..277V 60 Hz. 220..240V 50/60 Hz

    Schneider Electric MX release - 208..277V 60 Hz, 220..240V 50/60 Hz LV429387 MX shunt coil for Compact NSX, PowerPact Multistandard and EasyPact CVS circuit breakers. The nominal voltage is between 220 and 240 Vac at 50/60 Hz, or between 208 and 277 Vac at 60 Hz. PresentationRangeComPacTProduct range"ComPact NSX100...250""ComPacT NSX100. ..250 new generation""ComPact NSX400...630""ComPacT NSX400...630 new generation""ComPact NSX100...250 DC""ComPacT NSX100...250 DC new generation"ComPact NSX100 ...250 DC PV"ComPacT NSX100...250 DC PV new generation""ComPact NSX400...630 DC""ComPacT NSX400...630 DC new generation"ComPact NSX400...630 DC PV"ComPacT NSX400...630 DC PV new generation"Device nameMXProduct typeRelease coilApplicationControlvoltage release typeOpening coilOpening coil releaseControl voltage [Uc]220...240 V AC 50/60 Hz208...277 V AC 60 HzRange compatibility"ComPacT new generation" "ComPacT NSX new generation""ComPacT new generation" "ComPacT NSX DC new generation"Compact Compact NSXCompact ComPact NSX DCEasypact "EasyPact CVS"PowerPact PowerPact MultistandardTechnical specificationsOperating threshold0.7...1.1 One openingresponse time50 mscontrol signal typePulseMaintainedpulse duration>= 20 msinrush voltage power supply10 VAAuxiliary terminal blockSpring 0.5…1.5 mm² (AWG 20...AWG 16)wire stripping length7 mm

    €118,30

  • 5SL62327BB | Siemens Magnetic thermal switch 400V 6kA

    SIEMENS 5SL62327BB | Siemens Magnetic thermal switch 400V 6kA

    SIEMENS THERMIC MAGNETIC SWITCH 400V 6kA  5SL62327BB  Magneto-thermal switch 400V 6kA, 2 poles C, 32A, Italian version. Versionproduct brand SENTRONproduct name Circuit breaker General technical datanumber of poles 2pole design 2 polestrip characteristic class Cmechanical lifespan ( maneuver cycles) typ. 10 000overvoltage category IIIpollution degree 2 Voltagevoltage type of operational voltage ACinsulation voltage (Ui)● for multi-phase operation with AC rated value 440 V Supply voltagesupply voltage with AC nominal value 400 Vfrequency value range of the supply voltage 50/60 Hz Operating voltage● for multiphase operation with AC max. 440 V● with DC rated value max. 72 V Protection classIP protection degree IP20, with connected conductors Switching capacity current breaking capacity● according to EN 60898 rated value 6 kA● according to IEC 60947-2 rated value 6 kAenergy limitation class 3 Dissipationpower dissipation [W] at nominal current value with AC inhot operating state per pole 2.3 Wsuitability for use in Residential Construction / Infrastructure Detailsproduct feature● halogen-free Yes● sealable Yes● silicone-free Yesproduct expansion mountable built-in additionaldevices Yes Connectionsconnectable conductor section rigid wire

    €20,25

  • 1SDA054945R1 | Abb

    ABB 1SDA054945R1 | Abb

    Abb 1SDA054945R1 FRONT FOR LEVER CONTROL FOR EXTRACTABLE SWITCH T4-T5 Technical data Configuration type: Loose or Configurable Reference standards: IEC

    €74,85

  • 1SDA073881R1 | Abb

    ABB 1SDA073881R1 | Abb

    Abb 1SDA073881R1 HORIZONTAL MECHANICAL INTERLOCK BETWEEN 2 SWITCHES - TYPE A - STANDARD CABLES E1.2..E6.2-XT7-XT7M Technical data Auxiliary contacts, extendable No Number of NC contacts 0 Number of contacts NO 0

    €39,25

  • 2CSF204568R1250 | Abb

    ABB 2CSF204568R1250 | Abb

    Abb 2CSF204568R1250 MODULAR DIFFERENTIAL SWITCH MODEL F204 B DIFF.PURO 4P B 25 30 Technical data Number of poles 4 Rated voltage 400  V Rated current 25  TO Rated fault current 0.03  TO Rated insulation voltage Ui 440  V Rated impulse voltage resistance Uimp 4  kV Mounting method Mounting on g from DIN Differential type B Selective No Digital electronic control intervention time No Rated short-time current Icw 1  kA Resistance to nuisance trips (peak voltage surges) 3  kA Voltage type B.C With locking device No Frequency 50/60 Hz Accessorizable Yes Degree of protection (IP) IP20 Width in number of modules 4 Recess depth 69.5  mm Ambient temperature during operation -25...70  °C Degree of pollution 3 Connectable multi-strand (semi-rigid) conductor section 0...25  mm² Connectable single-wire (rigid) conductor section 1...25  mm² Explosion-proof No

    €585,75

  • 1SBN082306T1000 | Abb

    ABB 1SBN082306T1000 | Abb

    Abb 1SBN082306T1000 - BEA26-4 BEA26-4 is an insulated link used to connect AF26 ... AF38, AFC26 ... AFC38 or AFS26 ... AFS38 contactors with MS116-0,16 ... MS116-16 or MS132-0,16 ... MS132-10 manual motor starters. The BEA26-4 ensures the electrical and mechanical connection between a contactor or reversing contactors and the associated manual motor starter. Main features Type of accessory / spare part  -  Connection bridge

    €9,00

  • 5SV36126 | <tc>Siemens</tc>

    SIEMENS 5SV36126 | Siemens

    5SV36126 | Siemens Residual current circuit breaker, 2 pole, type A, In: 25 A, 300 mA, Un AC: 230 V Main features Number of poles - 2 Rated voltage - 230 V Rated current - 25 A Rated fault current - 300 A Mounting method - DIN rail mounting

    €87,95

  • 5SL62067BB | <tc>Siemens</tc>

    SIEMENS 5SL62067BB | Siemens

    Siemens 5SL62067BB Magneto-thermal switch 400V 6kA, 2 poles C, 6A, Italian version Technical datanumber of poles 2pole design 2 polestrip characteristic class Cmechanical lifespan (operating cycles) ● typ. 10 000overvoltage category IIIdegree of pollution 2Voltagetype of voltage of operational voltage ACtype of voltage Use only in alternating current circuits or in direct current circuits .Mixed use is not permittedinsulation voltage (Ui)● for multi-phase operation with AC rated value 440 Voperational current● at 30 °C rated value 6 A● at 40 °C nominal value 5.68 A● at 55 °C nominal value 5.17 A● with AC nominal value 6 A

    €23,00

  • 2CDS200936R0001 | Abb

    ABB 2CDS200936R0001 | Abb

    Abb 2CDS200936R0001 Auxiliary contact. Allows the indication of the position of the device contacts. Suitable for MCB S 200 series, SN 201 series (via the SN201-IH interface module), F 200 RCCB series, RCBO DS201 series, DS202C, DS 200 series. Technical data Function: Auxiliary contact Suitable for: S200 S200M S200P S200S S200 MT S200 MUC S300P Suitable for product class: Miniature Circuit Breaker Power loss: 1 W Maximum 1W Number of NC auxiliary contacts: 1 Number of auxiliary contacts NO: 1 Number of auxiliary contacts c/o (SPDT): 0 Accessory Type: Auxiliary contact Mounting position: left 

    €24,45

  • 1SDA068282R1 | Abb

    ABB 1SDA068282R1 | Abb

    Abb 1SDA068282R1 TMAX XT3S 250 FIXED THREE-POLE SWITCH WITH FRONT TERMINALS AND MAGNETIC RELEASES MA Iu 200 A I3=1200...2400 A Technical data Cable sections - main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour 8000 cycle(s) Mechanical durability: 240 cycles per hour 25000 cycle(s) Number of poles: 3 Opening duration: CB with SOR 15 ms CB with UVR 15ms Multiple Order: 1 piece(s) Power loss: at Nominal Operating Conditions for Pole 13.2 W Rated current (In): 200 A Nominal frequency (f): 50 / 60 Hz Impulse withstand voltage (Uimp): 8kV Instantaneous short-circuit rated current setting (Ii): 1200…2400 A Rated insulation voltage (Ui): 800 V Rated operating voltage: 690VAC 500V DC

    €600,00

  • 2CMA103572R1000 | Abb

    ABB 2CMA103572R1000 | Abb

    Abb 2CMA103572R1000 C11 is the simple and compact energy meter for insertion in 230 V AC networks up to 40 A. It is CE approved, equipped with outputs with pulse and alarm function, optional MID approval, 1 DIN module Technical data Function: Electricity meter Subfunction: Steel Nominal voltage (Ur): 230 V Voltage range: 184…264 V Rated current (In): 5 A Maximum 40 A Rated current: 5 A Nominal frequency (f): 50 / 60 Hz Power consumption (@Pcons): 0.22W Power loss: 0.22W Communication interface: It is not Precision: Active Energy Cl. ±1% (or B for MID meters) Measuring Instrument Conformity: IEC 62053-22 Meter Tariff Rating: One Tariff Pulse Output Rate: 1000 Number of poles: 1 Number of phases: Single phase

    €67,50

  • 1SDA067404R1 | Abb

    ABB 1SDA067404R1 | Abb

    Abb 1SDA067404R1 TMAX XT1C 160 FIXED FOUR-POLE SWITCH WITH FRONT TERMINALS AND THERMO-MAGNETIC RELEASES TMD R 63-630 A Technical data Cable sections - main circuit: Busbar 45.5 ... 80 mm² Current type: AC/DC Electrical life: 120 cycles per hour 8000 cycle(s) Mechanical durability: 240 cycles per hour 25000 cycle(s) Number of poles: 4 Opening duration: CB with SOR 15 ms CB with UVR 15ms Multiple Order: 1 piece(s) Power loss: at Nominal Operating Conditions for Pole 4.3 W Rated current (In): 63 A Nominal frequency (f): 50 / 60 Hz Impulse withstand voltage (Uimp): 8kV Instantaneous short-circuit rated current setting (Ii): 630 A Rated insulation voltage (Ui): 800 V

    €181,50

  • 1SCA120518R1001 | Abb

    ABB 1SCA120518R1001 | Abb

    Abb 1SCA120518R1001 OT160EV04 section 4P 160A power switch, with pistol handle, mounting on bottom plate Technical data Rated operating current AC-21A (Ie): (380 ... 415 V) 200 A (500V) 200A (690V) 200A Rated operating current AC-22A (Ie): (380 ... 415 V) 200 A (500V) 200A (690V) 160A Rated operating current AC-23A (Ie): (380 ... 415 V) 160 A (500V) 160A (690V) 160A Rated operating current AC-23a (Pe): (220 ... 240 V) 48 kW (400 ... 415 V) 88 kW (500V) 112kW (690V) 144kW Conventional free air thermal current (Ith): q = 40 °C 200 A Conventional thermal current (Ithe): Fully Enclosed 160A Impulse withstand voltage (Uimp): 12kV Rated insulation voltage (Ui): according to IEC/EN 60664-1 1000 V Rated operating voltage: Main Circuit 1000V Rated short circuit making capacity (Icm): (690V) 30kA Rated short-time withstand current (Icw): for 1 s 8 kA Power loss: at Nominal Operating Conditions for Pole 3.2 W Degree of pollution: 3

    €133,70

© 2024 DMSTECHMART, Powered by Shopify

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account