POWER DISTRIBUTION
-
SIEMENS 5SV13131KK16 | Siemens Differential circuit breaker 16a
SIEMENS RCBO 16a MTD 1P+N 1UM 4.5KA TYPE AC 30MA C16 5SV13131KK16 Compact residual current circuit breaker 1P+N 4.5 kA type AC 30 mA C16. The differential switch is the fault current protection device against accidental contacts. Number of protected poles: 1Rated current: 16 ARated fault current: 0.03 AType differential: ACWith neutral: yesNumber of poles (total) : 2Rated voltage: 230 VRated insulation voltage Ui: 253 VRated impulse voltage resistance Uimp: 4 kVLimiting class: 3Rated breaking capacity according to EN 61009: 4.5 kARated breaking capacity according to IEC 60947-2: 5 kARated short-circuit breaking capacity according to EN 61009-1: 4.5 kASwitch-off characteristics: Non-delayedType voltage: ACTripping characteristic: CWith locking device: yesOvervoltage category: 3Pollution degree: 2Ambient temperature during operation: -25.. .45 °CWidth in number of modules: 1Recessing depth: 70 mmRecess-mountable: yesProtection against unexpected start-up: yesDegree of protection (IP): IP20Connectable single-wire (rigid) conductor section: 0.75...16 mm²Connectable multi-wire (semi-rigid) conductor section: 0.75...16 mm²
€21,95
-
SCHNEIDER ELECTRIC R9D60616 | Schneider Electric Residual current circuit breakers (RCBOs)
Schneider Electric Residual current circuit breakers (RCBO), Resi9, 1P+N, 16 A, C curve, 4500 A, 30 mA, Type AC R9D60616 This Resi9 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole and 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. The earth leakage protection delay is instantaneous. The rated short-circuit breaking capacity Icn is up to 4500A according to EN/IEC 61009-2-1. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. It offers a reliable and safe solution for commercial and industrial applications with high breaking capacity. This product complies with IEC/EN 61009-2-1. It has an electrical resistance of up to 7500 cycles and a mechanical resistance of up to 20000 cycles. The EU operating voltage is 230 V AC. It can be installed on a DIN rail. Width in 9 mm steps is 4. The color of the product is white (RAL 9003). The dimensions are (W) 36mm x (H) 82mm x (D) 70.5mm. The weight is 186 g. It has an IP20 protection degree (according to the IEC/EN 60529 standard) which increases to IP40 if inserted in a modular cabinet. The operating temperature is between -25°C and -60 C. Technical dataRange"Resi9"Product name"Resi9 RCBO"Product typeDifferential magnetothermic switch (RCBO)Number of poles1P + Nneutral positionLeftnumber of protected poles1Rated current [In]16 AType of networkCARelease technologyMagnetothermalcode curveCdifferential sensitivity30 mAtiming differential protectionInstantaneoustype of differential protectionType ACInterrupting capacity4500 A compliant with CEI EN 61009-2-1 AC 50 Hzquality marksIMQFeatures techniquesdevice position in the systemStarting pointMains frequency50 HzRated operational voltage [Ue]230V AC 50 Hzmagnetic release limit5...10 x Indifferential technology"Voltage independent"Voltage insulation rating [Ui]400 VRated impulse withstand voltage [Uimp]4 kVpeak current250 Aposition signaling contactsYesType of controlLeverLocal signalingIndication ON/OFFInstallationHookupInstallationDIN railconnection pitch9 mm between phase e neutralpitch 9 mm4height82 mmwidth36 mmdepth70.5 mmproduct weight186 gColourWhiteDuration mechanical20000 cycleselectrical life7500 cyclesconnections - terminalsCage terminals (top or bottom) - 1...16 mm² - rigidCage terminals (top or bottom) - 1...10 mm² - flexibleCage terminals (top or bottom) - 1...10 mm² - flexible with ring nutwire stripping length13 mm for upper or lower part connectiontightening torque2 Nm upper or lower partprotection differentialIntegratedEnvironmentReference standardsCEI EN 61009-2-1CEI EN 61009-1degree of IP protectionIP20pollution degree2overvoltage categoryIIIAmbient temperature- 25…60 °C
€19,35
-
SCHNEIDER ELECTRIC PAS800 | Schneider Electric EcoStruxure Panel Server
Schneider Electric EcoStruxure Panel Server PAS800 - Advanced wireless and modbus datalogger, Energy Server, 110-277 VAC/DC
€889,50
-
FINDER 131182300000 | Finder call/reset relay din 17.5mm 1co
Finder call/reset relay din 17.5mm 1co 131182300000 Bistable call relay with reset command, changeover contact. Bistable operation with reset command particularly suitable for applications in the tertiary sector - public bathrooms, hospitals, hotels.Mounting on 5 mm bar Width 17.5 mm Features: Bistable operation with reset command particularly suitable for applications in the tertiary sector: public bathrooms, hospitals, hotels Mounting on 35 mm rail (EN 60715) or panel Contact configuration: 1 Exchange Nominal contact current: 12 A Dimensions: 17.5x84x56.5 mm Nominal /voltage: 230 V Nominal contact voltage: 250 V AC
€45,60
-
FINDER 7P2782750020 | Finder surge arrester
Finder surge arrester 7P2782750020 7P.27 Type 2 surge arrester (2 varistors) for single-phase TN systems with Neutral with L, N-PE varistor protection and replaceable varistor modules.Available with remote contact for signaling the status of the varistor. Features: Suitable for AC and DC systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of the status of the varistor - working/to be replaced Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Varistor and spark gap modules, replaceable Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715), 17.5 mm per pole
€72,95
-
FINDER 7M2482300210 | Finder bidirectional single-phase energy meter with LCD display
Finder bidirectional single-phase energy meter with LCD display 7M2482300210 The bidirectional single-phase energy meters with LCD display Type 7M.24.8.230.0001, Type 7M.24.8.230.0010, Type 7M.24.8.230.0210 and Type 7M.24.8.230.0310 are the ideal solution for monitoring domestic consumption/ industrial and specifically can be used in offices, for photovoltaic systems and for energy metering in campsites. They are programmable via smartphone thanks to NFC technology, which allows you to read the measured energy even in the absence of the mains. They are also distinguished by the touch navigation and programming button and the power and control terminals with integrated anti-theft lock. Other features: 4 MID certified meters for imported and exported active and reactive energy 8 resettable counters for active, reactive, apparent absolute, imported and exported energy Extensive measurements available: V, I, Pf, f, THD of voltage and current and operating time for preventive maintenance activities Mbus and Modbus RS485 communication protocol Technical data: Type of meter: ElectronicRated current (In): 5 AMaximum current (Imax): 40 A Nominal voltage (Un) N-L: 230...230 VFrequency: 50...60 Hz Accuracy class: BPolarity type: Single phaseModel: Direct measurement Type of energy measured: Active and reactive powerPulse output: NoneType of indication: Digital Mounting method: DIN RailWidth in number of modules: 1 Interface type: ModbusNumber of digits: 7 Protection degree (IP): IP50
€85,60
-
FINDER 7M2482300110 | Finder Bidirectional single-phase energy meter
Finder Bidirectional single-phase energy meter 7M2482300110 The bidirectional single-phase energy meters with LCD display Type 7M.24.8.230.0001, Type 7M.24.8.230.0010, Type 7M.24.8.230.0210 and Type 7M.24.8.230.0310 are the ideal solution for monitoring domestic consumption/ industrial and specifically can be used in offices, for example photovoltaic systems and for energy metering in campsites. They can be programmed via smartphone thanks to NFC technology, which allows you to read the measured energy even in the absence of the mains. They are also distinguished by the touch navigation and programming button and the power and control terminals with integrated anti-theft lock. Technical specifications:Type of meterElectronicRated current (In)5 AMaximum current (Imax)40 ANominal voltage (Un) N-L230...230 VFrequency50...60 HzPrecision classBType of polaritySingle phaseModelDirect measurementType of energy measuredActive power e reactiveCertifiedNationalPulse outputElectricPulse typeS0Pulse output frequency1000...1000 Imp/kWh (kKind of indicationDigitalMounting methodDIN railWidth in number of modules1Interface typeOthersNumber of digits7Degree of protection (IP)IP50
€67,45
-
FINDER 223400244320 | Finder 25 A modular contactor
Finder modular contactor 25 A 223400244320 Modular contactor 25 A - 4 contacts, 35mm width and a NO contact opening ≥ 3 mm, double break. Type 22.34 complies with EN 61095: 2009 Technical description: Modular contactor, 25 A, 4 contacts, NO, 25 A, AgSnO2, AC/DC coil, 24 V, operation from 19.2 to 26.4 V (AC)/( DC), rated power 2 VA (AC) / 2.2 W (DC), holding voltage 9.6 V (AC)/(DC), release voltage 2.4 V (AC)/(DC), variant: Mechanical indicator + LED, ambient temperature from -25 to +50 °C
€37,25
-
FINDER 223200124520 | Finder modular contactor
Finder modular contactor 223200124520 Modular contactor 25 A, 2 contacts, 17.5mm width, NO contact opening ≥ 3 mm, double break. Suitable for railway applications; plastic materials compliant with fire and smoke regulations (EN 45545-2 + A1: 2016). Technical description: Modular contactor, 25 A, 2 contacts, 1 NO + 1 NC, 25 A, AgSnO2, AC/DC coil, 12 V, operation from 9.6 to 13.2 V (AC)/(DC), rated power 2 VA (AC) / 2.2 W (DC), hold voltage 4.8 V (AC)/(DC), release voltage 1.2 V (AC)/(DC), variant: Mechanical indicator + LED, ambient temperature from -25 at +50 °C.
€26,35
-
FINDER 223200124340 | Finder Modular contactor
Finder Modular contactor 223200124340 25 A modular contactor, 2 contacts, 17.5mm width, NO contact opening ≥ 3 mm, double break. Suitable for railway applications; plastic materials compliant with fire and smoke regulations (EN 45545-2 + A1: 2016). Technical description: Modular contactor, 25 A, 2 contacts, NO, 25 A, AgSnO2, AC/DC coil, 12 V, operation from 9.6 to 13.2 V (AC)/(DC), rated power 2 VA (AC ) / 2.2 W (DC), hold voltage 4.8 V (AC)/(DC), release voltage 1.2 V (AC)/(DC), variant: Manual selector + mechanical indicator + LED, ambient temperature -25 to +50 °C.
€29,65
-
ABB 2CDS200922R0001 | Abb S2C-S/H6R
Abb Signaling/auxiliary contact 2CDS200922R0001 Signaling/auxiliary contact. Suitable for MCB S 200 series, SN 201 series (via SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical dataReference standards: CSA 22.2 No. 235GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function:Auxiliary / signaling contactSuitable for:S200S200MS200PS200SS300PSN201L+ SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Maximum 0.5 WNumber of auxiliary contacts NC:0Number of auxiliary contacts NO:0Number of auxiliary contacts c/o (SPDT):1Mounting position:right Environmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Information RoHS:9AKK108468A4564REACH Declaration:9AKK107492A1906SCIP:c151f68f-6fbb-44f7-badf-ba96efd56de4 Germany (DE)Conflict Minerals Reporting Template (CMRT):9AKK108468A3363 DimensionsProduct width:8.8 mmProduct height:85 mmProduct depth:69 mmProduct net weight:0.043 kg
€17,69
-
ABB 2CDS252001R0324 | Abb S202-C32
Abb Miniature circuit breaker - 2P - C - 32 A 2CDS252001R0324 System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. Technical dataReference standards:IEC/EN 60898-1IEC/EN 60947-2UL 107 Tripping characteristic: C Rated operating voltage:according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 440 V ACOperating voltage:Maximum (Incl . Tolerance) 125 V DCMaximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kV Dielectric test voltage:50/60 Hz, 1 min: 2 kVInput voltage type:AC/DCRated current (In):32 A Rated short-circuit capacity: (AC) 6 kA(DC) 6 kA(400 V AC) 6 kA(400 V) 6 kA Rated extreme short-circuit capacity (Icu): (125 V DC) 10 kA(230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kA(48 V DC ) 20 kA(230 V) 20 kA(400 V) 10 kA Rated conditional short-circuit current (Inc): (230 V) 20 kA(400 V) 20 kARated service short-circuit capacity (Ics):(230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kAFrequency (f):50 HzRated frequency (f):50 / 60 Hz50 ... 60 Hz Power loss: 7.4 Wa Nominal Operating Conditions for Polo 3.7 WSupply voltage connection:ArbitraryContact position indication:Red ON / Green OFF Energy limitation class: 3 Electrical resistance:10000 AC cycle (i)Mechanical resistance:20000 cycle (i)Number of protected poles:2Number of poles:2Overvoltage category: IIITightening torque:2.8 N mMounting type:DIN-RailScrew terminal type:Failsafe Bi-directional Cylinder-lift TerminalActuator labeling:I / OActuator material:Insulation Group II, Black, SealableCasing material:Insulation class II, RAL 7035DIN rail mounting:TH35-15 (35 x 15 mm Mounting Bar) according to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Bar) according to IEC 60715
€23,05