SCHNEIDER ELECTRIC INDUSTRIAL AUTOMATION
-
SCHNEIDER ELECTRIC XPSUAK12AP | Schneider-Electric safety module UAK 24V M.SCREW
Schneider-Electric safety module UAK 24V M.SCREW XPSUAK12AP The product is part of the XPS Universal security module range. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP and NPN sensors, RFID safety switches, safety barriers and sensitive mats/edges. PresentationProduct rangeHarmony Safety AutomationProduct typeSafety modulesafety module name XPSUAKsafety module applicationMonitored antivalent contactsFor emergency, protection and barrier monitoring4-wire pressure sensor monitoringModule function Emergency stop button with 2 NC contactsSafety monitoring with 1 or 2 limit switchesControl of 2 PNP sensorsMagnetic switch monitoringSafety barrier control RFID safety switch controlSafety barrier monitoring (ESPE)Safety mat controlProximity sensor monitoringMonitoring 1 PNP + 1 NPN sensor Safety levelCan reach PL e/category 4 for NO relay contact conforming to ISO 13849-1Can reach SILCL 3 for NO relay contact conforming to IEC 62061Can reach SIL 3 for NO relay contact conforming to IEC 61508Can reach PL c/category 1 for NC relay contact conforming to ISO 13849-1Can reach SILCL 1 for NC relay contact conforming to IEC 62061Can ' achieve SIL1 for NC relay contact conforming to IEC 61508Reliability data safetyMTTFd > 30 years conforming to ISO 13849-1Dcavg >= 99 % conforming to ISO 13849-1PFHd = 1.13E-09 conforming to ISO 13849-1HFT = 1 conforming to IEC 62061PFHd = 1.13E-09 conforming to IEC 62061SFF > 99% conforming to IEC 62061HFT = 1 conforming to IEC 61508-1PFHd = 1.13E-09 conforming to IEC 61508-1SFF > 99% conforming to IEC 61508-1Type = B conforming to IEC 61508-1topology of the networkNC doublePNP doubleAntivalent double OSSD doubleconnections - terminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexibleTerminal block removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible double conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with maskRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with maskVoltage nominal power supply [Us]24 V AC - 15...10 %24 V DC - 20...20 %Technical characteristicssynchronization time between inputs 0.5 s 2 s 4 sType of startingAutomatic/manual/monitoredPower absorbed in W2.0 W 24 V DCPower consumption in VA5.0 VA 24 V AC 50/60 Hztype of input protectionInternal, electronicsafety outputs2 NO + 1 NCsafety inputs2 safety input 24 V DC 5 mAmaximum wire resistance 500 OhmInput compatibilityNormally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850Double antivalent conforming to ISO 14119Double OSSD conforming to IEC 61496-1-23-wire PNP proximity sensorsRated operational current [Ie]5 A AC-1 for NO relay contact3 A AC-15 for NO relay contact5 A DC-1 for NO relay contact3 A DC-13 for NO relay contact 3 A AC-1 for NC relay contact1 A AC-15 for NC relay contact3 A DC-1 for NC relay contact1 A DC-13 for NC relay contactcontrol outputs 3 configurable on/off pulsed outputinput/output typePulsed semiconductor signaling output. 24 V DC, 20 mA Z1, non-safety relatedConventional thermal current in air [Ith]8 Aassociated fuse rating10 A gG for output circuit NO relay conforming to IEC 60947-1minimum output current10 mA per relay outputminimum output voltage12 V per relay outputRated insulation voltage [Ui]250 V (pollution degree 2) conforming to IEC 60947-1Rated impulse withstand voltage [Uimp]4 kV overvoltage category II conforming to IEC 60947-1Installation35 mm symmetrical DIN raildepth120 mmheight100 mmwidth22.5 mmproduct weight0.200 kg
€181,30
-
SCHNEIDER ELECTRIC LUB12 | Schneider Electric Power base - TeSys U - 12 A - Screw terminal control
Schneider Electric Power base - TeSys U - 12 A - Control screw terminals LUB12 TeSys U standard power base, 3 pole (3NO), 12 A/ 690 V, to be completed with a LUC control unit to form a TeSys U reversing starter controller, for 3-speed motor applications phases up to 5.5 kW at 400 V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to get an "all in one" starter controller with protection functions and basic or advanced control. It is equipped with a connection terminal block and closing shutters that cover the empty cavities. It provides a high breaking capacity Icu 50 kA at 400 V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm wide), DIN rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in combination with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), compliant with Green Premium (RoHS/REACh). Range: TeSysProduct Name: TeSys UltraDevice Name: LUBProduct Type : Power base with 1 direction of travelApplication: Motor control Motor protectionNumber of Poles: 3PAptitude for Insulation: YesNominal Operational Voltage [Ue]: 690 V AC for Power CircuitMains Frequency: 40...60 HzConventional Thermal Current In Air [Ith]: 12 ARated Operational Current [Ie] 12 A at 12 A at 500 V 9 A at 690 VUsage Category AC-43AC-44AC-41Rated Breaking Capacity Service [Ics]50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 VAuxiliary Contact Composition : 1 NO + 1 NCType of Auxiliary Contacts connected contact type (1 NO + 1 NC) conforming to IEC 60947-4-1mirror contact type (1 NC) conforming to IEC 60947-1 typical current consumption130 mA at 24 V DC I maximum during closing with LUCA, LUCB, LUCC, LUCD140 mA at 24 V AC I maximum during closing with LUCA, LUCB, LUCC, LUCD150 mA at 24 V DC I maximum during closing with LUCM280 mA at 110...220 V DC I maximum during closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum during closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum during closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum during closing with LUCA, LUCB, LUCC, LUCD35 mA at 110...220 V DC I rms fixed with LUCA, LUCB, LUCC, LUCD35 mA at 110...240 V AC I rms fixed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V AC I rms fixed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V DC I rms fixed with LUCA, LUCB, LUCC, LUCD60 mA at 24 V DC I rms fixed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V AC I rms fixed with LUCA, LUCB , LUCC, LUCD70 mA at 24 V DC I rms fixed with LUCMheat dissipation2 W for control loop with LUCA, LUCB, LUCC, LUCD 1.7 W per control circuit with LUCMSafety reliability levelB10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1B10d = 20000000 cycles Contactor with mechanical load compliant with EN /ISO 13849-1operating time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at >= 72 V closing with LUCA , LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for circuit control circuit75 ms closing with LUCM for control circuitMechanical life15 McyclesMaximum operating speed3600 cycles/hProduct certificationsCEULCSACCCEACASEFAATEXMarinaStandardsEN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase spreaderCSA C22.2 No 60947-4-1, with phase spreader phaseRated insulation voltage [Ui]690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1 600V compliant with CSA C22.2 No 60947-4-1Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-6-2safe circuit separation400 V SELV between auxiliary and control circuits conforming to IEC 60947-1 appendix N400 V SELV between auxiliary or control circuit and main circuit conforming to IEC 60947-1 appendix N type of fixingClip-on (DIN rail)Screw fixed (Plate)connections - terminalsControl circuit: screw fixing terminals 1 cables 0 ,34…1.5 mm² flexible with cable terminationControl circuit: screw fixing terminals 1 cables 0.75…1.5 mm² flexible without cable terminationControl circuit: screw fixing terminals 1 cables 0.75…1.5 mm² rigidControl circuit: screw fixing terminals 2 cables 0.34…1.5 mm² flexible with cable terminationControl circuit: screw fixing terminals 2 cables 0.75…1.5 mm² flexible without cable terminationControl circuit: screw fixing terminals 2 cables 0.75…1.5 mm² rigidPower circuit: screw fixing terminals 1 cables 1 …10 mm² rigidPower circuit: screw fixing terminals 1 cable 1…6 mm² flexible with cable terminationPower circuit: screw fixing terminals 1 cable 2.5…10 mm² flexible without cable termination Power circuit: screw fixing terminals 2 cables 1…6 mm² flexible with cable terminationPower circuit: screw fixing terminals 2 cables 1…6 mm² rigidPower circuit: screw fixing terminals screw fixing 2 cables 1.5…6 mm² flexible without cable terminationtightening torqueControl circuit: 0.8…1.2 Nm flat screwdriver 5 mmCircuit control: 0.8…1.2 Nm Philips no 1 screwdriver 5 mmPower circuit: 1.9…2.5 Nm flat screwdriver 6 mmPower circuit: 1.9…2.5 Nm Philips No 2 screwdrivers 6 mmPower circuit: 1.9…2.5 Nm pozidriv No 2 screwdrivers 6 mmwidth45 mmheight 154 mmdepth126 mmproduct weight0.9 kgCompatibility codeLUB
€64,40
-
SCHNEIDER ELECTRIC RSL1PVBU | Schneider Electric "SLIM" interface relay on screw base with LED and protection circuit, 24 V
Schneider Electric "SLIM" interface relay on screw base with LED and protection circuit, 24 V RSL1PVBU The Schneider Electric Slim RSL interface plug-in relay has a coil control voltage of 24 Vdc and has a SPDT (double throw single pole) switching contact rated at 6 Ampere. It has LED indicators and screw connectors. This slim interface plug-in relay reflects Schneider Electric's experience in the relay industry since 1924, helping to reduce cabinet size and at the same time increase machine reliability for industrial machinery, packaging, textile industry , HVAC, automation control panels, low/medium voltage distribution panels, motor controls, PLC interfaces, power supplies, building or medical equipment, lighting controls. It has a wide choice of contacts for high rated current use. It also offers an LED indicator and protection circuit. Technical dataProduct rangeHarmony Electromechanical Relaysrange nameInterface relayProduct type Pre-assembled plug-in relay with socketDevice nameRSLContact composition and type1 C/OContact operationStandardcontrol voltage [Uc]24 V DCConventional thermal current in enclosure [Ithe]6 A at -40…55 °CStatus LEDWithpin shapeFlat (PCB type) Type of fixingPlastic compression springmedium resistance3390 Ohm mains: DC at 23 °C +/- 10 % Rated insulation voltage [Ui]250 V conforming to IEC277 V conforming to cULRated impulse withstand voltage [Uimp]6 kV conforming to IECContact materialSilver alloy (AgSnO2)Rated operational current [Ie]6 A 1 C/O (AC -1/DC-1) IEC/UL compliantMinimum switching current100 mAmaximum switching voltage277 VMinimum switching voltage12 Vmaximum switching capacity1500 VA150 Wminimum switching capacity120 mWoperating rateMechanical durability10000000 cycleselectrical life60000 cycles for resistive load, 6 A at 250 V, AC-1operating time5 ms reset12 msmarkingCEprotection categoryRT IIItest levelsLevel A group mountingoperating positionAny positionheight78.6 mmwidth 6.2 mmdepth95 mmDescription of ISO terminals n°1(A1-A2)CO(11-12-14)OCsale indivisible quantity10product weight0.029 kgcurrent load6 A at 250 V AC Mounting distance of 0.5average absorption in W0.17 W, DCthreshold voltage dropout >= 0.05 Ucarrangement of contact terminalsSeparateconnections - terminalsScrew connectors, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable endScrew connectors, 1 x 0.2...1 x 2.5 mm² (AWG 24 ...AWG 14) solid without cable endtightening torqueSafety reliability dataB10d = 60000Control typeWithout buttonInstallation35 mm symmetrical DIN rail
€9,95
-
SCHNEIDER ELECTRIC ATV320U07N4C | Schneider Electric ATV320 speed variator
Schneider Electric ATV320 speed variator - 0.75kW - 380...500V - 3 phase - compact ATV320U07N4C The Altivar 320Schneider Electric speed variator is capable of powering 3-phase synchronous and asynchronous power motors with a nominal power of up to 0.75 kilowatts/1 horsepower and a nominal voltage of 380 to 500 Vac. This variable speed drive/frequency drive (VSD / VFD) is designed for simple industrial and commercial machines, such as packaging, material handling machinery, mechanical actuators and lifting devices. Its compact form factor allows you to reduce machine footprint by vertically stacking units in a machine frame. Advanced connectivity, including CANopen and Modbus, enables deep integration into automation architectures without the use of additional network equipment. Product Range: Altivar Machine ATV320Product Type: Variable speed driveProduct For Specific Applications: Complex MachinesVariant Version: standardDrive Format: CompactInstallation: Wall MountingPort Communication Protocol: Modbus serialCANopenNominal Power Voltage [Us]: 380...500 V - 15...10 %Nominal Output Current: 2, 3 A Technical characteristicsnumber of digital inputs7type of digital inputSTO safe torque off, 24 V DC, impedance: 1, 5 kOhmDI1...DI6 logic inputs, 24 V DC (30 V)DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)digital input logicPositive logic (source)Negative logic (current)number of digital outputs3type of digital outputOpen collector DQ+ 0…1 kHz 30 V DC 100 mAOpen collector DQ- 0…1 kHz 30 V DC 100 mAnumber of analog inputs3type of analog inputAI1 voltage: 0.. .10 V DC, impedance: 30 kOhm, 10 bit resolutionBipolar differential voltage AI2: +/- 10 V DC, impedance: 30 kOhm, 10 bit resolutionCurrent AI3: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other models for configuration), impedance: 250 Ohm, 10 bit resolutionnumber of analog outputs1type of analog outputCurrent configurable with AQ1 software: 0...20 mA impedance 800 Ohm, 10 bit resolutionVoltage configurable with AQ1 software: 0...10 V DC impedance 470 Ohm, 10 bit resolutionrelay output typeConfigurable relay logic R1A 1 NO electrical life 100000 cyclesConfigurable relay logic R1B 1 NC electrical life 100000 cyclesConfigurable relay logic R1CConfigurable relay logic R2A 1 NO electrical life 100000 cyclesConfigurable relay logic R2Cmaximum switching current: 3 A at 250 V AC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 3 A at 30 V DC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 2 A at 250 V AC on inductive load, cos phi = 0 ,4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 2 A at 30 V DC on inductive load, cos phi = 0.4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 5 A at 250 V AC on resistive load, cos phi = 1 R2A, R2C relay output: 5 A at 30V DC on resistive load, cos phi = 1 R2A, R2C relay outputminimum switching current: 5 mA at 24V DC R1A, R1B, R1C, R2A, R2C relay outputaccess method CANopen slave4 quadrant operation possibleTrueasynchronous motor control profileVoltage/frequency ratio, 5 pointsSensorless vector control, standardVoltage/frequency ratio - Energy saving, quadratic U/fSensorless vector control - Energy savingVoltage/frequency ratio, 2 pointsSynchronous motor control profileSensorless vector controltransient overtorque170…200 % of nominal motor torquemaximum output frequency0.599 kHzacceleration/deceleration rampsLinear USCUSRamp switchingAcceleration/deceleration ramp adaptationAutomatic acceleration/deceleration stop with DC injectionmotor slip compensationAny automatic loadAdjustable 0...300%Not available in voltage/frequency ratio (2 or 5 points)switching frequency2...16 adjustable kHz4...16 kHz with derating factornominal switching frequency4 kHzholding brakingWith injection DCIntegrated brake chopperTrueline current3.6 A at 380 V (heavy duty)2.8 A at 500 V (heavy duty)Maximum input current per phase3.6 AMaximum output voltage500 V apparent power2.4 kVA at 500 V (heavy duty)Mains frequency50...60 HzSymmetric relative mains frequency tolerance5 %Prospective line Isc5 kALoad current high-overload base7.1 Apower dissipation in W32.0 W fan: at 380 V, switching frequency 4 kHzWith function Safely Limited Speed (SLS)TrueWith safety function Safe Brake Management (SBC/SBT)FalseWith safety function Safe Operating Stop (SOS)False With safety function Safe Position (SP)FalseWith safety function Safe Programmable LogicFalseWith safety function Safe Speed Monitor (SSM)False With safety function Safe Stop 1 (SS1)TrueWith sft fct Safe Stop 2 (SS2)FalseWith safety function Safe Torque Off (STO)True With safety function Safe Limited Position (SLP)FalseWith safety function Safe Direction (SDI)Falsetype of protectionInterruption input phase: commandOvercurrent between output phases and earth : commandOverheating protection: commandShort circuit between phases of the motor: commandThermal protection: commandwidth105.0 mmheight 142.0 mmdepth158.0 mmproduct weight1.2 kg
€342,35
-
SCHNEIDER ELECTRIC ATV320U75N4B | Schneider-electric Speed variator
Schneider-electric Speed variator ATV320U75N4B The Altivar 320 Schneider Electric variable speed drive is capable of powering 3-phase synchronous and asynchronous power motors with a nominal power of up to 7.5kilowatts/10 horsepower and a nominal voltage of 380 to 500Vac. This variable speed drive/frequency drive (VSD / VFD) is designed for simple industrial and commercial machines, such as packaging, material handling machinery, mechanical actuators and lifting devices. Its Book form factor helps reduce machine footprint, especially when mounted in an electrical cabinet next to other control devices such as PLCs, I/O units. Advanced connectivity, including CANopen and Modbus, enables deep integration into automation architectures without the use of additional networking equipment. Technical dataProduct rangeAltivar Machine ATV320Product typeVariable speedproduct for specific applicationsComplex machinesvariantStandard versionvariator formatBookInstallationWall mountport communication protocolSerial ModbusCANopenoption boardCommunication module, CANopenCommunication module , EtherCATCommunication module, Profibus DP V1Communication module, ProfinetCommunication module, Ethernet PowerlinkCommunication module, Ethernet/IPCommunication module, DeviceNetPower supply voltage nominal [Us]380...500 V - 15...10 %nominal output current17.0 Apower motor in kW7.5 kW for heavy dutyEMC filterClass C2 integrated EMC filterIP protection degreeIP20number of digital inputs7type of digital inputSTO safe torque off, 24 V DC, impedance: 1.5 kOhmDI1...DI6 logic inputs, 24 V DC (30 V)DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)digital input logicPositive logic (source)Negative logic (current)number of digital outputs3type of digital outputCollector open DQ+ 0…1 kHz 30 V DC 100 mAOpen collector DQ- 0…1 kHz 30 V DC 100 mAnumber of analogue inputs3type analog input voltageVoltage AI1: 0...10 V DC, impedance: 30 kOhm, resolution 10 bitBipolar differential voltage AI2: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bitAI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other models per configuration), impedance: 250 Ohm, 10 bit resolution number of analogue outputs1type of analogue outputCurrent configurable with AQ1 software: 0...20 mA impedance 800 Ohm, resolution 10 bitVoltage configurable with software AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bitrelay output typeConfigurable relay logic R1A 1 NO electrical life 100000 cyclesConfigurable relay logic R1B 1 NC electrical life 100000 cyclesConfigurable relay logic R1CConfigurable relay logic R2A 1 NO electrical life 100000 cyclesConfigurable relay logic R2Cmaximum switching current: 3 A at 250 V AC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 3 A at 30 V DC on resistive load, cos phi = 1 R1A, R1B, R1C relay output: 2 A at 250 V AC on inductive load, cos phi = 0.4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 2 A at 30 V DC on inductive load, cos phi = 0.4 and L/R = 7 ms R1A, R1B, R1C, R2A, R2C relay output: 5 A at 250 V AC on resistive load, cos phi = 1 R2A, R2C relay output: 5 A at 30 V DC on resistive load , cos phi = 1 R2A, R2C relay outputminimum switching current: 5 mA at 24 V DC R1A, R1B, R1C, R2A, R2C relay outputaccess method Slave CANopen4 quadrant operation possibleTrueasynchronous motor control profileVoltage/frequency ratio, 5 pointsControl Sensorless Vector, StandardVoltage/Frequency Ratio - Energy Saving, Quadratic U/fSensorless Vector Control - Energy SavingVoltage/Frequency Ratio, 2 PointsMotor Control Profile synchronousVector control without sensortransient overtorque170…200 % of nominal motor torquemaximum output frequency0.599 kHzacceleration/deceleration rampsLinearUSCUSRamp switchingmotor slip compensationAny automatic load Adjustable 0...300%Not available in voltage/frequency ratio (2 or 5 points)switching frequency2...16 kHz adjustable4...16 kHz with derating factornominal switching frequency4 kHzholding brakingWith DC injection line current26.5 A at 380 V (heavy duty)18.7 A at 500 V (heavy duty)Maximum Input Current per phase26.5 AMaximum output voltage500 Vapparent power16.2 kVA at 500 V (use heavy)Mains frequency50...60 HzIsc prospective line22 kApower dissipated in W229.0 W fan: at 380 V, switching frequency 4 kHz With safety function Safely Limited Speed (SLS)TrueWith safety function Safe Brake Management (SBC/SBT)False With safety function Safe Operating Stop (SOS)FalseWith safety function Safe Position (SP)FalseWith safety function Logic programmable safeFalseWith Safe Speed Monitor (SSM) safety functionFalseWith Safe Stop 1 (SS1) safety functionTrueWith sft fct Safe Stop 2 (SS2)FalseWith Safe Torque Off (STO) safety functionTrue With safety function Safe Limited Position (SLP)FalseWith safety function Safe Direction (SDI)Falsetype of protectionInput phase interruption: commandOvercurrent between output phases and earth : commandOverheating protection: commandShort circuit between motor phases: commandThermal protection: commandwidth150 mmheight308.0 mmdepth 232.0 mmproduct weight4.4 kg
€1.031,20
-
SCHNEIDER ELECTRIC ABL8RPS24050 | Schneider-Electric universal power supply
Schneider-Electric universal power supply ABL8RPS24050 The Schneider Electric ABL8 regulated switching mode power supply provides direct current voltage, has a rated input of 100 to 500 Vac, a rated output current of 5 A at 24 Vdc and a rated power of 120 watts. PresentationProduct rangeModicon Power SupplyProduct typePower supplypower supply type Switching modeNominal input voltage100...120 V AC single phase, terminals: N-L1200...500 V AC phase to phase, terminals: L1-L2rated power in W 120 Woutput voltage 24 V DCoutput power supply current 5 Aadmissible temporary current amplification 1.5 x In (for 4 s)anti-harmonic filterLow frequency harmonic currentsTechnical characteristicsinput voltage limits85...132 V AC170...550 V ACinput current inrush 30 A18 mm modules0.51 at 240 V AC0.59 at 120 V ACefficiency 87 %Output voltage adjustment24...28, 8 V adjustablepower dissipated in W 15.5 WEquipment suppliedCorrector filter power factor compliant with IEC 61000-3-2output protection type Against overload, protection technology: manual or automatic resetAgainst overvoltage, protection technology: 30...32 V, manual resetAgainst short circuits, protection technology: manual or automatic resetAgainst undervoltage, protection technology: intervention with U Thermal, protection technology: automatic resetConnections - terminalsRemovable screw terminal block: 2 x 2.5 mm², for diagnostic relayScrew terminal blocks: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connectionScrew terminal blocks: 1 x 0.5... 1 x 4 mm², (AWG 22...AWG 12) for input earth connectionScrew terminal blocks: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connectionScrew terminal blocks: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output grounding connectionStatus LED1 LED (green and red) output voltage1 LED (green, red and orange) output currentdepth125 mmheight143 mmwidth56 mm product weight0.7 kgoutput connectionParallelSeries
€186,90
-
SCHNEIDER ELECTRIC VW3A3608 | Schneider-electric CANopen communication module
Schneider-electric CANopen communication module VW3A3608 The Altivar CANopen daisy chain communication module from Schneider Electric has 2 ports with RJ45 connectors. It complies with the CANopen Daisy Chain communication protocol. This communication module allows the integration of the drive into the CANopen daisy-chain process control network. Thanks to the removable modular design it is easy to install and remove from Altivar drives. It is compatible with Altivar Process ATV600 (ATV630, ATV650), Altivar Process ATV900 (ATV930, ATV950), Altivar Machine ATV320, Lexium 32, Altivar 32 and Altivar Machine ATV ATV340. Product rangeAltivarProduct typeCommunication moduleaccessories / element categoryAccessories communicationProduct compatibilityLexium 32Mrange compatibilityAltivar 32Altivar Machine ATV320Altivar Machine ATV340 except Sercos driveLexium 32Altivar Process ModularAltivar Process ATV900Altivar Process ATV600port communication protocolCANopen, CANmotionelectrical connection 2 RJ45 connectors
€71,70
-
SCHNEIDER ELECTRIC ABLM1A24012 | Schneider Electric Switching power supplies
Schneider Electric Switching power supplies, 100-240 V AC, 24 V 1.2 A, single phase, Modular ABLM1A24012 The ABLM regulated switching power supply (SMPS) provides direct current voltage. It has a rated input of 100V to 240V AC, a rated output current of 1.25A at 24V DC, and a rated power output of 30W. It is ideal for providing the DC voltage needed for automation equipment designed for industrial applications , commercial and residential. Examples: transportation, packaging, inspection, food and beverage, mining, oil and gas, and water. It is installed on an omega rail or fixed with a screw. Dimensions: Width 36mm, Height 91mm, Depth 55.6mm. Provides protection against overloads and short circuits with automatic restart after correction of the overload/short circuit source. Weight: 0.170kg. It is a rail mount industrial power supply. It complies with EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/ -1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1. The product is CE, CUL, RCM and CB Scheme certified. The Acti9 iC60 range of miniature circuit breakers is recommended for its protection. The type of protection is 4A, curve B or C. On the front there is an LED indicating the presence of DC output voltage and a QR code for access to the latest technical documentation. Thanks to their modular housing, they can be installed in industrial enclosures or panels by clip fixing on an omega (DIN) rail. Provides energy to automated systems. Designed for simple machines and applications, modular power supplies are appreciated above all for their extreme compactness. Product Range Modicon Power SupplyProduct Type Power SupplyPower Supply Type Switching ModeVariant Option ModularMaterial Cassette PlasticNominal Input Voltage 100...240 V AC single phase100...240 V AC phase to phase Rated Power In W 30 WOutput Voltage 24 V DCOutput Power Supply Current 1.25 AVoltage Limits In Input 90...264 V ACNominal Network Frequency 50…60 HzMaximum Leakage Current 0.25 mA 240 V ACType of Protection Input Integrated fuse (not replaceable) 3.15 AExternal protection (recommended) 20 A Curve BExternal protection (recommended) 20 A Curve CExternal protection (recommended) ) 4 A Curve BExternal protection (recommended) 4 A Curve CInrush Current 25 A at 115 V50 A at 230 VModules 18 mm 0.48 at 115 V AC0.38 at 230 V ACEfficiency 87 % at 115 V AC87 % at 230 V ACOutput Voltage Adjustment 24...28 V
€77,50
-
SCHNEIDER ELECTRIC LADN22 | Schneider-Electric auxiliary contacts front
Schneider-Electric auxiliary contacts fronta LADN22 LADN22 is an additional block of auxiliary contacts from Schneider Electric for TeSys D and TeSys F contactors. Front mounting block, it is equipped with 2NO+2NC instantaneous contacts up to 10 A 690 V AC. Can be used in safety applications thanks to certified NC mirror contacts. PresentationRangeTeSysTeSys DecaProduct nameTeSys DecaProduct type Auxiliary contact blockDevice nameLADNRange compatibilityTeSys D CADTeSys D LC1DTeSys F LC1FTeSys F CR1FTeSys Deca CADTeSys Deca LC1DInstallationFront sidePole contact composition2 NO + 2 NC Contacts operationInstantaneousRated operational voltage [Ue]690 V AC 25...400 HzRated operational current [Ie]6 A at 120 V AC-151.04 A at 690 V AC-150.55 A at 125 V DC-130.1 A at 600 V DC-13Rated insulation voltage [Ui]690 V conforming to IEC 60947-5-1600 V conforming to UL600 V conforming to CSAThermal current conventional in open air [Ith]10 A (at 60 °C)Reference standardsCEI EN 60947-5-1GB/T 14048.5Technical characteristicsRated making capacity Irms140 A AC conforming to IEC 60947-5-1250 A DC conforming to IEC 60947-5-1 Permissible temporary rated current100 A 60 °C 1 s120 A 60 °C 500 ms140 A 60 °C 100 msType of protectionGG fuse 10 AMechanical life30 McyclesMinimum switching current5 mAMinimum switching voltage17 V
€18,20
-
SCHNEIDER ELECTRIC BMXDDI3202K | Schneider Electric M340 digital input module
Schneider Electric M340 digital input module - 32 inputs - 24 V DC positive BMXDDI3202K The digital input module is part of the Modicon X80 modules. It has 32 isolated inputs and is powered by 24V DC. This input module with 40-way connectors is designed to be used in conjunction with the TeSys Quickfit mounting system. It occupies a single slot in the rack and has an enclosure that provides 20 protection to the electronics. Product Range Modicon Digital Input Type IsolatedInput Type Sink Current (Positive Logic)Digital Input Voltage 24V DC PositiveDigital Input Current 2.5 mAInput Compatibility With 2/3-wire proximity sensors conforming to IEC 60947-5-2With 2/3-wire proximity sensors conforming to IEC 61131-2 Type 1Sensor Power Supply 19...30 VCurrent State 1 Guaranteed >= 2 mACurrent State 0 Guaranteed Input Impedance 9600 OhmInsulation Resistance > 10 MOhm 500 V DCDissipated Power In W 3.9 WDc Typical Response Time 4 msDc Maximum Response Time 7 msParallelizing Inputs NoTypical Current Consumption 121 mA at 3.3 V DC
€390,30
-
SCHNEIDER ELECTRIC LXM32MD18N4 | Schneider-Electric modular 18A RMS PEAK 3PH 480V
Schneider-Electric modular 18A RMS PEAK 3PH 480V LXM32MD18N4 The Lexium 32 servo drive operates at a nominal supply voltage of 208 Vac to 480 Vac. It can power 3 phase BMH or BSH synchronous motors, its continuous output current is 6 A at 8 kHz. The compact size of the servo drive and associated servo motor provides maximum power in minimal space. PresentationProduct rangeLexium 32Product typeMotion servo driveDevice nameLXM32Mvariator formatBooknumber of phases of the networkThree-phaseNominal supply voltage [Us]200...240 V - 15...10 %380. ..480 V - 15...10 %power supply voltage limits170…264 V323…528 Vpower frequency50/60 Hz - 5...5 %Mains frequency47.5...63 HzEMC filterIntegratedcontinuous output current6 A at 8 kHzpeak current output 3s18 A at 208 V for 5 s18 A at 480 V for 5 sMaximum continuous power1700 W at 208 V 3300 W at 400 V3300 W at 480 VRated power supply1.2 kW at 208 V 8 kHz1.8 kW at 400 V 8 kHz1.8 kW at 480 V 8 kHzline current6 A 78 % at 208 V, with external line choke of 1 mH6.9 A 90 % at 400 V, with choke external line choke of 1 mH6 A 98 % at 480 V, with external line choke of 1 mH6.2 A 140 % at 208 V, without line choke5.2 A 161 % at 400 V, without line choke4.5 A 165 % at 480 V, without line chokeTechnical characteristicsswitching frequency 8 kHzovervoltage category IIImaximum leakage current 30 mAoutput voltageelectrical isolationBetween power and controlcable typeIEC cable single stranded 50 °C) copper 90 °C XLPE/EPRelectrical connectionTerminal, clamping capacity: 3 mm², AWG 12 (CN8)Terminal, clamping capacity: 5 mm², AWG 10 (CN1)Terminal, capacity tightening torque: 5 mm², AWG 10 (CN10)tightening torque0.5 Nm CN8:0.7 Nm CN1:0.7 Nm CN10:number of digital inputs 2 Acquisition of discrete inputs2 security of discrete inputs4 logic of discrete inputstype of digital inputAcquisition (CAP terminals)Logic (DI terminals)Safety (compliment of STO_A, compliment of STO_B terminals)
€991,50
-
SCHNEIDER ELECTRIC SR3B261BD | Schneider Electric zelio logic modular smart relay
Schneider Electric Zelio Logic modular smart relay - 26 I/O - 24 V DC - Clock - Display SR3B261BD The Zelio Logic SR3 compact / programmable controller from Schneider Electric uses a supply voltage of 24 V DC, has 26 inputs/outputs with screw terminals. It has a built-in clock and an LCD display. This compact programmable logic module is ideal for managing, remote controlling or monitoring simple automation systems. It is suitable for both industrial and commercial applications. It features a compact form factor that allows for DIN rail installation. It also offers simple programming, viewing and diagnostic functions for display and navigation button malfunctions. Local Display WithNumber O Lines Control Scheme 0…500 with FBD programming0…240 with programming scale Life Cycle 6…90 msBackup Time 10 years at 25 °CClock Drift 12 min/year at 0…55 °C 6 s/month at 25 °CControls Program memory at each start-upNominal supply voltage [Us] 24 V Power Supply Voltage Limits 19.2…30 VMaximum Supply Current 190 mA (without extension module)300 mA (with extensions)Power Dissipation In W 10 W with extensions6 W without extension moduleReverse Polarity Protection WithNumber of Digital Inputs 16 conforming to IEC 61131-2 Type 1Digital Input Type ResistiveDigital Input Voltage 24 V DCDigital Input Current 4 mA
€243,00