ABB

329 products

  • ES 992 7 | Abb

    ABB ES 992 7 | Abb

    Abb ES 992 7 ABB ES 992 7 PM582

    €532,15

  • ES 991 9 | Abb S.P.A.

    ABB ES 991 9 | Abb S.P.A.

    Abb S.P.A. ES 991 9 AC500 CPU: 2 internal serial interfaces, configurable rs-232/rs-485. Display and 8 function keys for diagnostics and status. Centrally expandable up to 10 i/o modules (possibility of using s500 and/or s500-eco modules). Simultaneous operation of up to 4 external communication modules, in any combination. Optional SD card for data storage and program backup. It can also be used as a slave with profibus® dp, devicenet orcanopen® via, fieldbusplug, canopen®, also using the cm588 slave communication module. The Ethernet version provides a web server and the IEC 60870-5-104 remote control protocol.

    €1.097,65

  • 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    ABB 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    Abb XT3N 250 TMD 250-2500 4p F F InN=50% 1SDA068066R1 Tmax XT3N 250 fixed four-pole circuit breaker with front terminals and thermomagnetic releases TMD R 250-2500 A neutral = 50% phases. Technical data  Type of switch to associate: Power Distribution Cable sections-main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour8000 cycle (i) Mechanical durability: 240 cycles per hour25000 cycle (i) Number of poles: 4 Opening duration: CB with SOR 15 msCB with UVR 15 ms Multiple order: 1 piece(s) Loss of power: a Nominal Operating Conditions for Polo 17.8 W Product main type: SACE Tmax XT Product name: Moulded-case switch Product type: Automatic Circuit Breaker Rated current (In): 250 A Nominal frequency (f): 50 / 60 Hz Rated voltage (Ur): 690 V Impulse withstand voltage (Uimp): 8 kV Rated instantaneous short-circuit current setting (Ii): 2500 A Rated insulation voltage (Ui): 800V Rated operating voltage: 690 V AC500 V DC  

    €952,90

  • 1SAE231111R0131 | Abb ESB25-31N-01

    ABB 1SAE231111R0131 | Abb ESB25-31N-01

    Abb ESB25-31N-01 1SAE231111R0131 Modular contactors - Automatic control - 3 n.o. contacts + 1 n.c. contact Technical data Rated operating voltage: Main Circuit 220 V DCMain Circuit 400 V AC Nominal control circuit voltage (Uc): 24V Nominal frequency (f): Control Circuit 400 HzControl Circuit 50 HzControl Circuit 60 HzDC Control CircuitMain Circuit 50 HzMain Circuit 60 HzMain Circuit DC Rated operating current AC-1 (Ie): (NC) 25 A(NO) 25 A Rated operating current AC-3 (Ie): (230 V) Single Phase, NC 6 A(230 V) Single Phase, NO 9 A(400 V) Three Phase, NO 9 A Rated operating current AC-1 (Pe): (230 V) Single Phase, NC 5.8 kW(230 V) Single Phase, NO 5.8 kW(400 V) Three Phase, NO 17.3 kW Rated operating current AC-3 (Pe): (230 V) Single Phase, NC 1.3 kW(230 V) Single Phase, NO 1.3 kW(400 V) Three Phase, NO 4 kW Rated operating current AC-7a (Ie): (NC) 25 A(NO) 25 A Rated operating current AC-7a (Pe): (230 V) Single Phase, NC 5.8 kW(230 V) Single Phase, NO 5.8 kW(400 V) Three Phase, NO 17.3 kW Rated operating current AC-7b (Ie): (230 V) Single Phase, NC 6 A(230 V) Single Phase, NO 9 A(400 V) Three Phase, NO 9 A Rated operating current AC-7b (Pe): (230 V) Single Phase, NC 0.9 kW(230 V) Single Phase, NO 1.3 kW(400 V) Three Phase, NO 4 kW Recommended screwdriver: Control Circuit Pozidriv 1Main Circuit Pozidriv 1 Impulse withstand voltage (Uimp): 6 kV Rated insulation voltage (Ui): 500V Cable sections - main circuit: Flexible with Ferrule 1x 1.5 ... 10 mm²Flexible with Ferrule 2x 1.5 ... 2.5 mm²Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²Flexible with Insulated Ferrule 2x 1.5 mm² Flexible 1x 1.5 ... 10 mm²Flexible 2x 1.5 ... 4 mm²Rigid 1x 1.5 ... 10 mm²Rigid 2x 1.5 ... 4 mm² Control circuit-cable sections: Flexible with Ferrule 1x 1 ... 2.5 mm²Flexible with Ferrule 2x 0.75 ... 1 mm²Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 . .. 1 mm²Flexible 1x 1 ... 4.0 mm²Flexible 2x 1 ... 2.5 mm²Rigid 1x 1 ... 4 mm²Rigid 2x 1 ... 2.5 mm² Tightening torque: Control Circuit 0.9 N mMain Circuit 1 N m Cable stripping length: Control Circuit 7 mmMain Circuit 10 mm Degree of protection: IP20 Electrical life: AC-1 (NC) 50000 cycle (i)AC-1 (NO) 130000 cycle (i)AC-3 (NC) 340000 cycle (i)AC-3 (NO ) 500000 cycle (i)AC-7a (NC) 50000 cycle (i)AC-7a (NO) 130000 cycle (i)AC-7b (NC) 340000 cycle (i)AC-7b (NO) 500000 cycle (i) Mechanical durability: 1000000 cycle (i) Number of poles: 4 Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of NC main contacts: 1 Number of main NA contacts: 3 Width in number of modular intervals: 2 Pollution degree: 3 Reference standards: IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 61095UL 60947-1UL 60947-4-1 UL/CSA Technical Department Maximum operating voltage UL/CSA: Main Circuit 480 V AC UL/CSA Scope: (220 ... 240 V AC) Single Phase, NC 1 Hp(220 ... 240 V AC) Single Phase, NO 1 Hp(220 ... 240 V AC) Three Phases, NO 3 Hp(440 ... 480 V AC) Single Phase, NC 2 Hp(440 ... 480 V AC) Single Phase, NO 2 Hp(440 ... 480 V AC) Three Phases , NO 5 Hp UL/CSA main circuit cable cross sections: Solid 16-8 AWGStranded 16-8 AWG UL/CSA control circuit cable cross sections: Solid 16-10 AWGStranded 16-10 AWG UL/CSA tightening torque: Control Circuit 8 in lbMain Circuit 9 in lb

    €44,40

  • 2CSM228735R0802 | Abb TM15/12

    ABB 2CSM228735R0802 | Abb TM15/12

    Abb TM15/12 2CSM228735R0802 Failure-proof doorbell transformers. Voltage: primary 230 V AC - secondary 4-8-12 V a.c. SELV or 12-24 V AC SELV. Technical data Reference standards: IEC/EN 61558-2-8 Application: Residential Primary voltage: 230V Secondary voltage: (6-7) 4 V AC(5-6) 8 V AC(5-7) 12 V AC Secondary current: 1.25 A Maximum output current (Iout): 3.75 A Nominal frequency (f): 50/60 Hz Loss of power: 2.5 W Power: 15 V·A Rated output power: 15 W Insulation class: B Tightening torque: 0.5 N·m

    €18,45

  • 2CDS200912R0001 | Abb S2C-H6R

    ABB 2CDS200912R0001 | Abb S2C-H6R

    Abb S2C-H6R 2CDS200912R0001 Order Code: A563826 - Auxiliary contact. allows the indication of the position of the device contacts. Suitable for MCB S 200 series, SN 201 series (via the SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical data Reference standards: CSA Class 3215-30CSA Class 3215-90GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function: Auxiliary contact Suitable for: S200S200MS200PS200SS300PSN201L+SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Suitable for product class: Miniature Circuit BreakerResidual Current Device Loss of power: 0.5 WMaximum 0.5 W Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of auxiliary contacts c/o (SPDT): 1 Accessory type: Auxiliary contact Mounting position: right Technical information: AUXILIARYCONTACT

    €20,60

  • 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    ABB 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    Abb DDA204 AC-63/0.3 2CSB204001R3630 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type AC Rated voltage (Ur): 230/400 V Rated operating voltage: 230/400 V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 300 mA Leakage Current Type: AC Nominal frequency (f): 50 … 60 Hz Loss of power: 7.6 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 4 Operational characteristic: Instant Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²

    €112,95

  • 1sda066325r1 - ABB

    ABB 1SDA066325R1 | ABB SOR-C XT1..XT4 F/P. Wired opening release

    Abb SOR-C XT1..XT4 F/P 1SDA066325R1 WIRED OPENING RELEASE 220-240V AC-220-250V DC FOR FIXED-REMOVABLE XT1..XT4 Additional information Configuration type: Loose or Configurable Current type: AC/DC Multiple order: 1 piece(s) Product main type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Rated voltage (Ur): 220 ... 240 V AC220 ... 250 V DC Reference standards: IECUL Suitable for: XT1, XT2, XT3, XT4 Suitable for product class: SACE Tmax XT

    €90,30

  • 2CMA100164R1000 | Abb B23 112-100

    ABB 2CMA100164R1000 | Abb B23 112-100

    Abb B23 112-100 2CMA100164R1000 Order Code: B231121 - The B series EQ Meters are characterized by their compactness and are the ideal solution for 230 V AC systems. both single-phase and three-phase. They allow you to view, depending on the version chosen, the following quantities: active, reactive, apparent energy; active, reactive, apparent power; currents; frequency; tensions; division of consumption into tariffs; power factor; bidirectional consumption. All codes are certified according to the MID directive, are equipped with outputs for managing pulses or alarms, and an infrared port for communication with KNX adapter. Depending on the version, the meters are equipped with integrated serial communication interfaces for Modbus RTU (RS485 version) and Meter BUS (M-Bus versions) Technical data Reference standards: EN 50470-1 Function: Electricity meter Subfunction: Steel Rated voltage (Ur): 3x220-240 V Voltage range: 3x176…276 V Rated current (In): 5 AMaximum 65 A Rated current: 5 A Nominal frequency (f): 50 / 60 Hz Power consumption (@Pcons): 0.721 W Communication interface: Modbus RS485 Accuracy: Active Energy Cl. ±1% (or B for MID meters) Measuring Instrument Conformity: Measurement Instrument Directive (MID) Meter Tariff Rating: One-Tariff Pulse Output Rate: 1-999999 Number of poles: 4 Number of phases: Three-phase Number of Counter Positions: 7 Number of digital inputs/outputs: 1 C Type of measurement: Direct connection Mounting type: DIN rail Pulse Output Type: Electrical Type of Indicator: Digital Container material: Plastic I/O option: 1 digital output Communication: Modbus RTU Cable sections-main circuit: 1 ... 25 mm²

    €241,80

  • 2CSB202701R1630 | Abb DDA202 A-63/0.03 AE

    ABB 2CSB202701R1630 | Abb DDA202 A-63/0.03 AE

    Abb DDA202 A-63/0.03 AE 2CSB202701R1630 Order Code: B428017 - The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type A Application: For emergency stop Rated voltage (Ur): 230/400 V Rated operating voltage: 230V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 30 mA Leakage Current Type: A Nominal frequency (f): 50 … 60 Hz Loss of power: 5 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 2 Operational characteristic: Instantaneous (AE for Emergency Stop) Provided options: For emergency stop Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²  

    €188,05

  • 2CDS242701R0164 | Abb S202L-C16

    ABB 2CDS242701R0164 | Abb S202L-C16

    Abb S202L-C16 2CDS242701R0164 The System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200 series differential blocks. Technical data Reference standards: IEC/EN 60898-1IEC/EN 60947-2 Trip characteristic: C Rated operating voltage: according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 400 V AC Operating voltage: Maximum (Incl. Tolerance) 440 V ACMinimum 12 V AC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kV Dielectric test voltage: 50/60 Hz, 1 min: 2 kV Input voltage type: AC Rated current (In): 16 A Short-circuit rating: (AC) 4.5 kA(DC) 4.5 kA(400 V AC) 4.5 kA(400 V) 4.5 kA Rated extreme short-circuit capacity (Icu): (230 V AC) 10 kA(400 V AC) 6 kA(230 V) 10 kA(400 V) 6 kA Rated conditional short-circuit current (Inc): (400 V) 6 kA Rated service short-circuit capacity (Ics): (230 V AC) 7.5 kA(400 V AC) 4.5 kA Nominal frequency (f): 50 / 60 Hz50 ... 60 Hz Loss of power: 5 Wa Nominal Operating Conditions for Polo 2.5 W Supply voltage connection: Arbitrary Contact position indication: ON / OFF

    €9,50

  • 1SDA067130R1 | Abb RC Sel HV 85...690Vac XT3 4p F

    ABB 1SDA067130R1 | Abb RC Sel HV 85...690Vac XT3 4p F

    Abb RC Sel HV 85...690Vac XT3 4p F 1SDA067130R1 RC sel HV 85...690V AC residual current release for XT3 four-pole fixed inter. Configuration type: Loose or Configurable Number of poles: 4 Multiple order: 1 piece(s) Main product type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Reference standards: IEC Suitable for: XT3 Suitable for product class: SACE Tmax XT  

    €706,60

  • 1SBL137001R1110 | Abb AF09-30-10-11

    ABB 1SBL137001R1110 | Abb AF09-30-10-11

    Abb AF09-30-10-11 1SBL137001R1110 The AF09-30-10-11 is a 3-pole contactor - 690 V IEC or 600 UL with 1 built-in auxiliary contact and screw terminals, which controls motors up to 4 kW / 400 V AC (AC-3 ) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general purpose. Thanks to AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumption and ensuring smooth operation. distinguished in unstable networks. Additionally, surge protection is built-in, offering a compact solution. AF contactors have a block design, they can be easily expanded with additional auxiliary contact blocks and a wide range of additional accessories. Technical data Number of main NA contacts: 3 Number of main NC contacts: 0 Number of auxiliary contacts NO: 1 Number of NC auxiliary contacts: 0 Reference standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1 Rated operating voltage: Auxiliary Circuit 690 VMain Circuit 690 V Nominal frequency (f): Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 HzMain Circuit 50 / 60 Hz Conventional thermal current in free air (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 35 Aaccording to IEC 60947-5-1, q = 40 °C 16 A Rated operating current AC-1 (Ie): (690 V) 40 °C 25 A(690 V) 60 °C 25 A(690 V) 70 °C 22 A

    €21,15

  • 1SAE341111R0131 | Abb ESB40-31N-01

    ABB 1SAE341111R0131 | Abb ESB40-31N-01

    Abb ESB40-31N-01 1SAE341111R0131 Technical data Rated operating voltage: Main Circuit 220 V DCMain Circuit 400 V AC Nominal control circuit voltage (Uc): 24V Nominal frequency (f): Control Circuit 400 HzControl Circuit 50 HzControl Circuit 60 HzDC Control CircuitMain Circuit 50 HzMain Circuit 60 HzMain Circuit DC Rated operating current AC-1 (Ie): (NC) 30 A(NO) 40 A Rated operating current AC-3 (Ie): (230 V) Single Phase, NO 22 A(400 V) Three Phase, NO 22 A Rated operating current AC-1 (Pe): (230 V) Single Phase, NC 6.9 kW(230 V) Single Phase, NO 9.2 kW(400 V) Three Phase, NO 27.7 kW Rated operating current AC-3 (Pe): (230 V) Single Phase, NO 3.7 kW(400 V) Three Phase, NO 11 kW Rated operating current AC-7a (Ie): (NO) 40 A Rated operating current AC-7a (Pe): (230 V) Single Phase, NC 6.9 kW(230 V) Single Phase, NO 9.2 kW(400 V) Three Phase, NO 27.7 kW Rated operating current AC-7b (Ie): (230 V) Single Phase, NO 22 A(400 V) Three Phase, NO 22 A Rated operating current AC-7b (Pe): (230 V) Single Phase, NO 3.7 kW(400 V) Three Phase, NO 11 kW Recommended screwdriver: Control Circuit Pozidriv 1Main Circuit Pozidriv 2 Impulse withstand voltage (Uimp): 6 kV Rated insulation voltage (Ui): 500V Cable sections-main circuit: Flexible with Ferrule 1x 1.5 ... 16 mm²Flexible with Ferrule 2x 1.5 ... 10 mm²Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²Flexible with Insulated Ferrule 2x 1.5 . .. 10 mm²Flexible 1x 1.5 ... 16 mm²Flexible 2x 1.5 ... 10 mm²Rigid 1x 1.5 ... 25 mm²Rigid 2x 1.5 ... 10 mm² Control circuit-cable sections: Flexible with Ferrule 1x 0.75 ... 2.5 mm²Flexible with Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 . .. 1 mm²Flexible 1x 1 ... 4.0 mm²Flexible 2x 1 ... 2.5 mm²Rigid 1x 1 ... 4 mm²Rigid 2x 1 ... 2.5 mm² Tightening torque: Control Circuit 0.9 N·mMain Circuit 2.5 N m Cable stripping length: Control Circuit 7 mmMain Circuit 13 mm Degree of protection: IP20 Electrical life: AC-1 (NC) 70000 cycle (i)AC-1 (NO) 150000 cycle (i)AC-3 (NO) 100000 cycle (i)AC-7a (NC ) 70000 cycle (i)AC-7a (NO) 150000 cycle (i)AC-7b (NO) 100000 cycle (i) Mechanical durability: 1000000 cycle (i) Number of poles: 4 Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of NC main contacts: 1 Number of main NA contacts: 3 Width in number of modular intervals: 3 Pollution degree: 3 Reference standards: IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 61095UL 60947-1UL 60947-4-1

    €100,55

  • 2CSB204101R1400 | Abb DDA204 A-40/0.03

    ABB 2CSB204101R1400 | Abb DDA204 A-40/0.03

    Abb DDA204 A-40/0.03 2CSB204101R1400 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. GType of residual current: Type A Rated voltage (Ur): 230/400 VRated operating voltage: 230/400 VRated insulation voltage (Ui): 500 VImpulse withstand voltage ( Uimp): 4 kV Rated current (In): 40 ARated residual current: 30 mALeakage Current Type: ARated frequency (f): 50 … 60 Hz Power loss: 4.8 WSupply voltage connection: ArbitraryElectrical resistance: 10000 cycle(s) Number of poles: 4Operational characteristic: InstantaneousConnection capacity: Rigid 16 ... 16 mm²Flexible 16 ... 16 mm²

    €179,80

  • 1SDA067121R1 | Abb RC Sel 200 HV 85...690Vac XT1 4p F

    ABB 1SDA067121R1 | Abb RC Sel 200 HV 85...690Vac XT1 4p F

    Abb RC Sel 200 HV 85...690Vac XT1 4p F 1SDA067121R1 RC SEL 200 low residual current release for MOD.200mm HV 85...690V AC for inter. fixed four-pole XT1. Technical data Configuration type: Loose or Configurable Number of poles: 4 Multiple order: 1 piece(s) Product main type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Reference standards: IEC Suitable for: XT1 Suitable for product class: SACE Tmax XT  

    €527,00

  • 2CSM260113R0801 | Abb TM-S 250/12-24 P

    ABB 2CSM260113R0801 | Abb TM-S 250/12-24 P

    Abb safety transformer 250VA 2CSM260113R0801 TM-S transformers are ideal for powering very low safety voltage SELV circuits. Technical dataReference standards: EN 61558-2-2, EN 61558-2-6, UL506, CSA C22-2-N66Rated insulation voltage (Ui) :4.8 kVPrimary voltage:230-400 ±15 V ACSecondary voltage:12-24 V ACRated frequency (f):50/60 HzPower loss:38 WPower supply:250 V AInsulation class:FType of fuse:aMMaterial of Conductor:CopperCable section:6 mm² Environmental dataAmbient temperature: max. 40 °CRoHS Declaration: According to EC Directive 2011/65/ECRoHS Information:9AKK106713A5642REACH Declaration:9AKK108467A9482Environmental information: Please refer to RoHS InformationConflict Minerals Reporting Template (CMRT):9AKK108468A3363 DimensionsProduct width:100 mmProduct height:0.105 mProduct depth:110 mmProduct net weight:3,600 kg InstallationInstructions and manuals: No document neededWiring diagram:9AKK108466A7520Download Most usedTechnical sheet:2CSC446005B0202Inrush Power Curve :9AKK108467A2987Transformer Protection Selection Table:9AKK108467A2982Power Draw According to Altitude:9AKK108467A2983Power Draw According to Temperature:9AKK108467A2985Admissible Overload:9AKK108467A2986

    €112,95

  • 2CSJ201001R0002 | Abb RD3

    ABB 2CSJ201001R0002 | Abb RD3

    Abb RD3 2CSJ201001R0002  The differential relays with external toroidal transformer allow protection against earth faults. Using the minidip it is possible to adjust the sensitivity and the intervention time. Technical data Reference standards IEC EN 60947-2 Ann MType of residual current Type AFunction For mixed system Rated voltage (Ur) 400...400 VRated operating voltage 230 ... 400 V ACVoltage nominal control power supply (Us) (50 Hz) 400...400 V(60 Hz) 400...400 V Rated current Response value amperage 1 500 ... 500 mARated frequency (f) 50 … 60 HzLoss of power 3.6 W Number of contacts 2Number of c/o contacts 1Number of NC contacts 0Number of NO contacts 0Delay time (τ) Delay-On Energization, Maximum, Permitted 10 second [time unit]Delay-On Energization, Minimum, Adjustable 0 second [time unit]Mounting type DIN railFilter option no frequency filter Options provided Pre-alarm threshold: no

    €197,05

  • 1SVR500020R1100 | Abb CT-MFD.21

    ABB 1SVR500020R1100 | Abb CT-MFD.21

    CT-MFD.21 TEMPORARY RELAY MULTIFUNCTION  1SVR500020R1100 They are used when the command of utilities is required based on a time interval. Technical dataType of timer relay:ON-DelayOFF-DelayImpulse ONImpulse OFFFlasher Starting with ONFlasher Starting with OFFPulse Former Time range: 0.05 s ... 100 hRated control supply voltage (Us): 12 ... 240 V AC/DCRated operating voltage: Auxiliary circuit 250 V Rated frequency (f):DC50 / 60 HzOutput:2 c/o (SPDT) contacts Clamp type: Screw TerminalsRated operating current AC-12 (Ie):(230 V) 5 ARated operating current AC-15 (Ie):(230 V) 3 ARated operating current DC-12 (Ie):(24 V) 5 ARated operating current DC-13 (Ie):(24 V) 1 AImpulse withstand voltage (Uimp): Input Circuit 4 kVRated insulation voltage (Ui):Input Circuit / Output Circuit 300 VOutput Circuit 1 / Output Circuit 2 300 V Degree of protection: Home IP50Terminals IP20Overvoltage category:IIIPollution degree:3Short circuit protection devices:NC Output Circuit - Type F fuses 6 ANO Output Circuit - Type F Fuses 6 AConnection capacity:Flexible 1x 0.5 ... 2.5 mm²Flexible 2x 0.5 ... 1.5 mm²Rigid 1x 0.5 ... 4 mm²Rigid 2x 0.5 ... 1.5 mm²

    €112,30

  • 4016779649728 | Abb S2C-A2L

    ABB 4016779649728 | Abb S2C-A2L

    A2L TRIP COIL 110-415V AC 4016779649728 The shunt coil is used to cause the remote opening of the switch to which it is associated by applying voltage. Technical dataFunction:Shunt TripPower loss:0 WEnvironmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019RoHS information:2CDK400627D2701REACH Declaration:9AKK107492A1906SCIP:4906475e-2b37-45cb-918c-db295dd155a2 Germany (DE)Conflict Minerals Reporting Template (CMRT) :9AKK108468A3363 DimensionsProduct width:17.5 mmProduct height:69 mmProduct depth:85 mmProduct net weight:0.14 kg

    €30,00

  • 1SDA066820R1 | Abb XT1B 160 TMD 160-1600 4p F F InN=50%

    ABB 1SDA066820R1 | Abb XT1B 160 TMD 160-1600 4p F F InN=50%

    Abb XT1B 160 TMD 160-1600 4p F F InN=50% 1SDA066820R1 TMAX XT1B 160 fixed four-pole circuit breaker with front terminals and TMD R 160-1600 thermomagnetic releases with neutral = 50% phases. Type of switch to be associated Power DistributionCable sections - main circuit Busbar 45.5 ... 80 mm²Type of current AC/DC Electrical life 120 cycles per hour8000 cycle (i)Mechanical life 240 cycles per hour25000 cycle (i) Number of poles 4Opening time CB with SOR 15 msCB with UVR 15 ms Multiple order 1 piece(s)Power loss at Nominal Operating Conditions for Polo 15 WMain product type SACE Tmax XTProduct name Molded case circuit breakerProduct type Automatic Circuit Breaker Rated current (In) 160 ARated frequency (f) 50 / 60 Hz Rated voltage (Ur) 690 VImpulse withstand voltage (Uimp) 8 kVRated instantaneous short-circuit current setting (Ii) 1600 ARated insulation voltage (Ui) 800 VRated operating voltage 690 V AC500 V DC

    €513,40

  • 2CSF202001R4250 | Abb F202 AC-25/0.5

    ABB 2CSF202001R4250 | Abb F202 AC-25/0.5

    Abb 500MA switch. differenti. pure 2CSF202001R4250 Pure RCDs without thermal-magnetic releases are switches that guarantee the protection of people from indirect contact. Technical data: Reference standards:IEC/EN 61008UL 1053Type of residual current:AC typeRated voltage (Ur):230 VRated operating voltage :230 VRated insulation voltage (Ui):500 VImpulse withstand voltage (Uimp):4 kVRated current (In):25 ARated residual current:500 mA Rated conditional short-circuit current (Inc):10 kARated service short-circuit capacity (Ics):1 kAMaximum Surge Current:0.25 kALeakage Current Type:ACFrequency nominal (f):50 … 60 HzPower loss:a Nominal Operating Conditions per Pole 1 WSupply voltage connection:ArbitraryElectrical resistance:10000 cycle (i)Number of poles :2Operating characteristic:Instant Mounting type: DIN-RailOptions Provided:NoneAccessories Available:YesConnection Capability:Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... . 55 °CAmbient temperature:In operation -25...55 °CDegree of protection:IP2XDegree of pollution:2Vibration resistance according to IEC 60068-2-6:0.1 mm or 1 g - 20 cycles at 5…150…5 HzShock resistance according to IEC 60068-2-27:25g 2 shocks 13 ms

    €78,60

  • 2CDS200922R0001 | Abb S2C-S/H6R

    ABB 2CDS200922R0001 | Abb S2C-S/H6R

    Abb Signaling/auxiliary contact 2CDS200922R0001 Signaling/auxiliary contact. Suitable for MCB S 200 series, SN 201 series (via SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical dataReference standards: CSA 22.2 No. 235GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function:Auxiliary / signaling contactSuitable for:S200S200MS200PS200SS300PSN201L+ SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Maximum 0.5 WNumber of auxiliary contacts NC:0Number of auxiliary contacts NO:0Number of auxiliary contacts c/o (SPDT):1Mounting position:right Environmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Information RoHS:9AKK108468A4564REACH Declaration:9AKK107492A1906SCIP:c151f68f-6fbb-44f7-badf-ba96efd56de4 Germany (DE)Conflict Minerals Reporting Template (CMRT):9AKK108468A3363 DimensionsProduct width:8.8 mmProduct height:85 mmProduct depth:69 mmProduct net weight:0.043 kg

    €14,15

  • 1SAM250000R1007 | Abb MS116-2.5

    ABB 1SAM250000R1007 | Abb MS116-2.5

    Abb Motor protectors and thermal relays-Protection switches 1SAM250000R1007 Motor protectors and thermal relays-Class 10 thermal magnetic protection switches-MS116 class 10 motor protectors. Technical dataRated service short-circuit capacity (Ics):(230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 10 kA(500 V AC) 10 kA(690 V AC) 5 kA Rated extreme short-circuit capacity (Icu):(230 V AC) 75 kA(400 V AC) 75 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 10 kA Setting instantaneous rated short-circuit current (Ii):31.3 ASetting range:1.6 ... 2.5 ARated operating current AC-3 (Pe) :(400 V) Three Phases 0.75 kWRated operating current AC-3e (Pe):(400 V) Three Phases 0.75 kW Rated operating voltage: Main Circuit 690 V ACRated operating current (Ie):2.5 ARated operating current AC-3 (Ie):2.5 ARated operating current AC-3e (Ie):2.5 A Nominal frequency (f): Main Circuit 50 HzMain Circuit 60 HzImpulse withstand voltage (Uimp):Main Circuit 6 kVRated insulation voltage (Ui):690 VLeakage power: at Nominal Operating Conditions for Pole 0.7 ... 1.8 W Number of poles: 3Conventional free air thermal current (Ith): Main Circuit 2.5 A Degree of protection: Housing IP20Main Circuit Terminals IP10 Pollution degree: 3Electrical life:100000 cycle (i)Mechanical life:100000 cycle (i)Terminal type:Screw TerminalsCable sections - main circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²Tightening torque:Main Circuit 0.8 ... 1.2 N·mCable stripping length:Main Circuit 9 mm  

    €59,05

© 2024 DMSTECHMART, Powered by Shopify

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login