FREE SHIPPING throughout Europe.

DIFFERENTIAL AUTOMATIC SWITCHES AND MODULAR ACCESSORIES

32 products



  • magnetotermico differenziale 16a - 5SV13131KK16

    SIEMENS 5SV13131KK16 | Siemens Differential circuit breaker 16a

    SIEMENS RCBO 16a MTD 1P+N 1UM 4.5KA TYPE AC 30MA C16                            5SV13131KK16  Compact residual current circuit breaker 1P+N 4.5 kA type AC 30 mA C16. The differential switch is the fault current protection device against accidental contacts. Number of protected poles: 1Rated current: 16 ARated fault current: 0.03 AType differential: ACWith neutral: yesNumber of poles (total) : 2Rated voltage: 230 VRated insulation voltage Ui: 253 VRated impulse voltage resistance Uimp: 4 kVLimiting class: 3Rated breaking capacity according to EN 61009: 4.5 kARated breaking capacity according to IEC 60947-2: 5 kARated short-circuit breaking capacity according to EN 61009-1: 4.5 kASwitch-off characteristics: Non-delayedType voltage: ACTripping characteristic: CWith locking device: yesOvervoltage category: 3Pollution degree: 2Ambient temperature during operation: -25.. .45 °CWidth in number of modules: 1Recessing depth: 70 mmRecess-mountable: yesProtection against unexpected start-up: yesDegree of protection (IP): IP20Connectable single-wire (rigid) conductor section: 0.75...16 mm²Connectable multi-wire (semi-rigid) conductor section: 0.75...16 mm²

    €21,94

  • 5SL62327BB | Siemens Magnetic thermal switch 400V 6kA

    SIEMENS 5SL62327BB | Siemens Magnetic thermal switch 400V 6kA

    SIEMENS THERMIC MAGNETIC SWITCH 400V 6kA  5SL62327BB  Magneto-thermal switch 400V 6kA, 2 poles C, 32A, Italian version. Versionproduct brand SENTRONproduct name Circuit breaker General technical datanumber of poles 2pole design 2 polestrip characteristic class Cmechanical lifespan ( maneuver cycles) typ. 10 000overvoltage category IIIpollution degree 2 Voltagevoltage type of operational voltage ACinsulation voltage (Ui)● for multi-phase operation with AC rated value 440 V Supply voltagesupply voltage with AC nominal value 400 Vfrequency value range of the supply voltage 50/60 Hz Operating voltage● for multiphase operation with AC max. 440 V● with DC rated value max. 72 V Protection classIP protection degree IP20, with connected conductors Switching capacity current breaking capacity● according to EN 60898 rated value 6 kA● according to IEC 60947-2 rated value 6 kAenergy limitation class 3 Dissipationpower dissipation [W] at nominal current value with AC inhot operating state per pole 2.3 Wsuitability for use in Residential Construction / Infrastructure Detailsproduct feature● halogen-free Yes● sealable Yes● silicone-free Yesproduct expansion mountable built-in additionaldevices Yes Connectionsconnectable conductor section rigid wire

    €25,89

  • 2CDS252001R0324 | Abb S202-C32

    ABB 2CDS252001R0324 | Abb S202-C32

    4 in stock

      Abb  Miniature circuit breaker - 2P - C - 32 A 2CDS252001R0324 System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. Technical dataReference standards:IEC/EN 60898-1IEC/EN 60947-2UL 107 Tripping characteristic: C Rated operating voltage:according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 440 V ACOperating voltage:Maximum (Incl . Tolerance) 125 V DCMaximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kV Dielectric test voltage:50/60 Hz, 1 min: 2 kVInput voltage type:AC/DCRated current (In):32 A Rated short-circuit capacity: (AC) 6 kA(DC) 6 kA(400 V AC) 6 kA(400 V) 6 kA Rated extreme short-circuit capacity (Icu): (125 V DC) 10 kA(230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kA(48 V DC ) 20 kA(230 V) 20 kA(400 V) 10 kA Rated conditional short-circuit current (Inc): (230 V) 20 kA(400 V) 20 kARated service short-circuit capacity (Ics):(230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kAFrequency (f):50 HzRated frequency (f):50 / 60 Hz50 ... 60 Hz Power loss: 7.4 Wa Nominal Operating Conditions for Polo 3.7 WSupply voltage connection:ArbitraryContact position indication:Red ON / Green OFF Energy limitation class: 3   Electrical resistance:10000 AC cycle (i)Mechanical resistance:20000 cycle (i)Number of protected poles:2Number of poles:2Overvoltage category: IIITightening torque:2.8 N mMounting type:DIN-RailScrew terminal type:Failsafe Bi-directional Cylinder-lift TerminalActuator labeling:I / OActuator material:Insulation Group II, Black, SealableCasing material:Insulation class II, RAL 7035DIN rail mounting:TH35-15 (35 x 15 mm Mounting Bar) according to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Bar) according to IEC 60715

    4 in stock

    €41,06

  • R9D60616 | <tc>Schneider Electric</tc> Residual current circuit breakers (RCBOs). Returns9. 1P+N. 16 A. curve C. 4500 A. 30 mA. AC type

    SCHNEIDER ELECTRIC R9D60616 | Schneider Electric Residual current circuit breakers (RCBOs). Returns9. 1P+N. 16 A. curve C. 4500 A. 30 mA. AC type

    7 in stock

    Schneider Electric Residual current circuit breakers (RCBO), Resi9, 1P+N, 16 A, C curve, 4500 A, 30 mA, Type AC R9D60616 This Resi9 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole and 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. The earth leakage protection delay is instantaneous. The rated short-circuit breaking capacity Icn is up to 4500A according to EN/IEC 61009-2-1. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. It offers a reliable and safe solution for commercial and industrial applications with high breaking capacity. This product complies with IEC/EN 61009-2-1. It has an electrical resistance of up to 7500 cycles and a mechanical resistance of up to 20000 cycles. The EU operating voltage is 230 V AC. It can be installed on a DIN rail. Width in 9 mm steps is 4. The color of the product is white (RAL 9003). The dimensions are (W) 36mm x (H) 82mm x (D) 70.5mm. The weight is 186 g. It has an IP20 protection degree (according to the IEC/EN 60529 standard) which increases to IP40 if inserted in a modular cabinet. The operating temperature is between -25°C and -60 C. Technical dataRange"Resi9"Product name"Resi9 RCBO"Product type Residual current circuit breaker (RCBO)Number of poles1P + Nneutral positionLeftnumber of protected poles1Rated current [In]16 AType of networkCA Release technologyMagnetothermalcurve codeCdifferential sensitivity30 mAdifferential protection timingInstantaneoustype of differential protectionType ACInterrupting capacity4500 A compliant with CEI EN 61009-2-1 AC 50 Hzquality brandsIMQTechnical characteristicsdevice position in the systemStarting pointMains frequency50 HzRated operational voltage [Ue]230 V AC 50 Hzmagnetic release limit5 ...10 x Indifferential technology"Voltage independent"Rated insulation voltage [Ui]400 VRated impulse withstand voltage [Uimp]4 kVpeak current250 Acontact position signalingYesType of controlLeverLocal signalingON/OFF indicationInstallationCoupling InstallationDIN railconnection pitch9 mm between phase and neutral9 mm pitch4height82 mmwidth36 mmdepth70.5 mmproduct weight186 gColorWhiteMechanical durability20000 cycleselectrical life7500 cyclesconnections - terminalsCage terminals (top or bottom) - 1...16 mm² - rigidCage terminals (top or bottom) - 1...10 mm² - flexibleCage terminals (top or bottom) - 1...10 mm² - flexible with ring nutwire stripping length13 mm for upper or lower part connectiontightening torque2 Nm upper or lower part differential protectionIntegratedEnvironmentReference standardsCEI EN 61009-2-1 CEI EN 61009-1IP protection degreeIP20pollution degree2overvoltage categoryIIIAmbient temperature-25…60 °C

    7 in stock

    €19,31

  • PAS800 | Schneider Electric EcoStruxure Panel Server

    SCHNEIDER ELECTRIC PAS800 | Schneider Electric EcoStruxure Panel Server

    Schneider Electric EcoStruxure Panel ServerPAS800 Technical data Range "EcoStruxure"Product Name "Panel Server Advanced"Product Type Gateway Device Name "PAS800"Application GatewayEnergy serverData loggerNominal Voltage Of Power [Us]"110...277 V" AC 50/60 Hz"110...277 V" DCCommunication Gateway Ethernet TCP/IP to wireless devicesEthernet/serialPower Consumption In W 3.5 W "110...277 V" Communication Network Type Ethernet, 10/100BASE-TWi-Fi"2.4 GHz"Wi-Fi"5 GHz"Wireless, "IEEE 802.15. 4"Modbus RTU, Modbus RTU client even/odd or no parity, at "1.2...115.2 kbit/s"Modbus TCP Communication Port ProtocolDHCP HTTPSNTP/SNTP"IPv4""IPv6"TCP/IPCommunication Port Protocol2 RJ45: EthernetTerminal block screw: RS485Number Of Server 32 slave(s)Modbus RTU - without repeater128 slave(s)Modbus RTU - with repeater128 slave(s)Modbus TCP40 slave(s)"IEEE 802.15.4"Memory Capacity "32 GB" "eMMC"512 MB NANDNumber Of Inputs 0Connections - Terminals Power supply: screw terminal (top) 1.5…2.5 mm² cables Communication: screw terminal ( lower part) 0.14…1.5 mm² cablesTightening torque Power supply: 0.6 NmCommunication: 0.25 NmStrip length Wires Power: 7 mmCommunication: 7 mmConnector Type RP-SMA antennaInstallation HookingInstallation DIN railProduct certifications CEcULusRCM"UKCA"FCC IC Reference standards IEC 61010 IEC 61010-1 IEC 61010-2-201 UL 61010 UL 61010-1 UL 61010-2-201"CSA C22.2 No 61010-1-12"CSA C22.2 No 61010-2-201"IEC 62974-1""IEC 62443 -4-1"IEC 61326-1"EN 301-489-1""EN 301-489-17"EN 301-893"EN 55032"CISPR 11"EN 300-328"IEEE 802.15.4"IEEE 802.11a/b/g/n"Depth 70.2 mm Height 93 mmWidth 72 mmProduct Weight 206 g

    €992,34

  • LV429387 | <tc>Schneider Electric</tc> MX release - 208..277V 60 Hz. 220..240V 50/60 Hz

    SCHNEIDER ELECTRIC LV429387 | Schneider Electric MX release - 208..277V 60 Hz. 220..240V 50/60 Hz

    Schneider Electric MX release - 208..277V 60 Hz, 220..240V 50/60 Hz LV429387 MX shunt coil for Compact NSX, PowerPact Multistandard and EasyPact CVS circuit breakers. The nominal voltage is between 220 and 240 Vac at 50/60 Hz, or between 208 and 277 Vac at 60 Hz.  PresentationRangeComPacTProduct range"ComPact NSX100...250""ComPacT NSX100. ..250 new generation""ComPact NSX400...630""ComPacT NSX400...630 new generation""ComPact NSX100...250 DC""ComPacT NSX100.. .250 DC new generation"ComPact NSX100...250 DC PV"ComPacT NSX100...250 DC PV new generation""ComPact NSX400...630 DC""ComPacT NSX400 ...630 DC new generation"ComPact NSX400...630 DC PV"ComPacT NSX400...630 DC PV new generation"Device nameMXProduct typeRelease coilApplicationControltype of voltmetric releaseOpening coilRelease coilRelease voltage command [Uc]220...240 V AC 50/60 Hz208...277 V AC 60 HzRange compatibility"ComPacT new generation" "ComPacT NSX new generation""ComPacT new generation" "ComPacT NSX DC new generation"Compact Compact NSXCompact ComPact NSX DCEasypact "EasyPact CVS"PowerPact PowerPact MultistandardTechnical specificationsOperating threshold0.7...1.1 One openingresponse time50 mscontrol signal typePulseMaintained pulse duration>= 20 mspower supply inrush voltage10 VAAuxiliary terminal blockSpring 0.5…1.5 mm² (AWG 20 ...AWG 16)wire stripping length7 mm

    €118,30

  • LV426708 | Schneider-electric Circuit breaker

    SCHNEIDER ELECTRIC LV426708 | Schneider-electric Circuit breaker

    Schneider-electric Compact NSXm Vigi circuit breaker 160A 4P 16kA EverLink connector LV426708 LV426708 is a Compact NSXm RCD with Micrologic Vigi 4.1 control unit, 160 A, 16 kA at 415 VAC. It is designed for all standard LV applications. Provides integrated earth leakage protection for transformer-powered distribution systems. It features new features such as Everlink connector technology. It offers plate and DIN rail mounting capabilities and externally visible spring-loaded auxiliaries. This 4 pole integrated residual current circuit breaker (ELCB) is one of the smallest on the market. Dimensions: 108mm (W) x 144mm (H) x 80mm (D). Ensures compliance with international standards (IEC 60947/CCC/EACH) and marine specifications. Technical dataRangeCompactProduct nameCompact NSXmProduct rangeCompact NSXmDevice name"NSXm 160E"Product typeResidual current circuit breakerApplicationProtection DistributionNumber of poles4Pprotected poles description"4D"neutral positionLeftRated current [In]160 A at 40 °CRated operational voltage [Ue]440 V AC 50/ 60 HzType of networkCANetwork frequency50/60 HzAbility to sectioningComplies with EN/IEC 60947-2Usage categoryCategory A[Icu] rated ultimate short-circuit breaking capacity 25 kA Icu compliant with IEC 60947-2 at 220...240 V AC 50/60 Hz16 kA Icu compliant with IEC 60947-2 at 380...415 V AC 50/60 Hz10 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 HzPerformance levelE 16 kA 415 V ACTrip name "Micrologic 4.1"Trip technologyElectronictrip protection functionsLSoIRType of controlLeverCircuit breaker mounting modeWith screwsChangingRated insulation voltage [Ui]500 V AC 50/60 Hz Rated impulse withstand voltage [Uimp]8 kV[Ics] rated service short-circuit breaking capacity25 kA at 220. ..240 V AC 50/60 Hz conforming to IEC 60947-216 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-210 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Mechanical durability20000 cyclesElectrical durability10000 cycles at 440 V In20000 cycles at 440 V In/2InstallationPlateDIN railConnection terminals1 Everlink connector 2.5…70 mm², flexible copper1 Everlink connector 2.5…95 mm², rigid or stranded aluminium/copperPitch connection35 mm with diffusers27 mm Without spacers9 mm pitches12 moduletype of protectionL : for overload protection (thermal)"So" : for short-term short-circuit protection with fixed delayI : for instantaneous short-circuit protectionR : for earth differential protection Release rating160 A at 40 °Cthermal memory20 minutes before and after the tripdifferential protectionIntegrated Earth-leakage protection sensitivity adjustment type IΔnAdjustable[IΔn] earth-leakage protection sensitivity adjustment range0.03…5 Adifferential sensitivity30 mA for class A100 mA for class A300 mA for class A500 mA for class A1000 mA for class A 30 mA for class AC100 mA for class AC300 mA for class AC500 mA for class AC1000 mA for class AC3000 mA for class AC5000 mA for AC classEarth leakage protection delay adjustment type Δt Adjustable[Dt] Erth-leakage prefix delay adjustment range price 0 ms60 ms150 ms500 ms1000 msSecurity settingsNo protection 1 x Ir0.5 x IrNumber of slots for electrical auxiliaries1 slot for auxiliary contact OF1 slot for alarm contact SD1 slot for opening coil "MN or MX"local signalingLED flashing (green) ready for operation:LED 105% Ir (red)Overload:LED 90% Ir (orange)Overload :Width108 mmHeight144 mmDepth80 mmproduct weight1.63 kgColourGrey (RAL 7016)  

    €996,30

  • 1489M3D150 | Allen-bradley UL489 15 A miniature circuit breaker

    ALLEN-BRADLEY 1489M3D150 | Allen-bradley UL489 15 A miniature circuit breaker

    Allen-bradley UL489 15 A miniature circuit breaker  1489M3D150 Miniature switch, 15 A, 3 pole, 480Y/277Volt AC, type D trip curve, inductive. Technical data Recess depth: 79.38 mm Trip characteristic: D Number of poles (total): 3 Rated current: 15 A Rated voltage: 400 V Voltage type: AC Rated breaking capacity Icu according to IEC 60947-2 at 230 V: 15 kA Rated breaking capacity Icu according to IEC 60947-2 at 400 V: 15 kA Frequency: 50...60 Hz With neutral: no Overvoltage category: 3 Pollution degree: 3 Can be accessorised: yes Protection degree (IP): IP20

    €86,69

  • 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    ABB 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    Abb XT3N 250 TMD 250-2500 4p F F InN=50% 1SDA068066R1 Tmax XT3N 250 fixed four-pole circuit breaker with front terminals and thermomagnetic releases TMD R 250-2500 A neutral = 50% phases. Technical data  Type of switch to associate: Power Distribution Cable sections-main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour8000 cycle (i) Mechanical durability: 240 cycles per hour25000 cycle (i) Number of poles: 4 Opening duration: CB with SOR 15 msCB with UVR 15 ms Multiple order: 1 piece(s) Loss of power: a Nominal Operating Conditions for Polo 17.8 W Product main type: SACE Tmax XT Product name: Moulded-case switch Product type: Automatic Circuit Breaker Rated current (In): 250 A Nominal frequency (f): 50 / 60 Hz Rated voltage (Ur): 690 V Impulse withstand voltage (Uimp): 8 kV Rated instantaneous short-circuit current setting (Ii): 2500 A Rated insulation voltage (Ui): 800V Rated operating voltage: 690 V AC500 V DC  

    €952,88

  • 2CSM228735R0802 | Abb TM15/12

    ABB 2CSM228735R0802 | Abb TM15/12

    Abb TM15/12 2CSM228735R0802 Failure-proof doorbell transformers. Voltage: primary 230 V AC - secondary 4-8-12 V a.c. SELV or 12-24 V AC SELV. Technical data Reference standards: IEC/EN 61558-2-8 Application: Residential Primary voltage: 230V Secondary voltage: (6-7) 4 V AC(5-6) 8 V AC(5-7) 12 V AC Secondary current: 1.25 A Maximum output current (Iout): 3.75 A Nominal frequency (f): 50/60 Hz Loss of power: 2.5 W Power: 15 V·A Rated output power: 15 W Insulation class: B Tightening torque: 0.5 N·m

    €18,45

  • 2CDS200912R0001 | Abb S2C-H6R

    ABB 2CDS200912R0001 | Abb S2C-H6R

    Abb S2C-H6R 2CDS200912R0001 Order Code: A563826 - Auxiliary contact. allows the indication of the position of the device contacts. Suitable for MCB S 200 series, SN 201 series (via the SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical data Reference standards: CSA Class 3215-30CSA Class 3215-90GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function: Auxiliary contact Suitable for: S200S200MS200PS200SS300PSN201L+SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Suitable for product class: Miniature Circuit BreakerResidual Current Device Loss of power: 0.5 WMaximum 0.5 W Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of auxiliary contacts c/o (SPDT): 1 Accessory type: Auxiliary contact Mounting position: right Technical information: AUXILIARYCONTACT

    €20,60

  • 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    ABB 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    Abb DDA204 AC-63/0.3 2CSB204001R3630 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type AC Rated voltage (Ur): 230/400 V Rated operating voltage: 230/400 V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 300 mA Leakage Current Type: AC Nominal frequency (f): 50 … 60 Hz Loss of power: 7.6 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 4 Operational characteristic: Instant Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²

    €112,93

  • 2CSB202701R1630 | Abb DDA202 A-63/0.03 AE

    ABB 2CSB202701R1630 | Abb DDA202 A-63/0.03 AE

    Abb DDA202 A-63/0.03 AE 2CSB202701R1630 Order Code: B428017 - The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type A Application: For emergency stop Rated voltage (Ur): 230/400 V Rated operating voltage: 230V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 30 mA Leakage Current Type: A Nominal frequency (f): 50 … 60 Hz Loss of power: 5 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 2 Operational characteristic: Instantaneous (AE for Emergency Stop) Provided options: For emergency stop Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²  

    €188,04

  • 2CDS242701R0164 | Abb S202L-C16

    ABB 2CDS242701R0164 | Abb S202L-C16

    Abb S202L-C16 2CDS242701R0164 The System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200 series differential blocks. Technical data Reference standards: IEC/EN 60898-1IEC/EN 60947-2 Trip characteristic: C Rated operating voltage: according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 400 V AC Operating voltage: Maximum (Incl. Tolerance) 440 V ACMinimum 12 V AC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kV Dielectric test voltage: 50/60 Hz, 1 min: 2 kV Input voltage type: AC Rated current (In): 16 A Short-circuit rating: (AC) 4.5 kA(DC) 4.5 kA(400 V AC) 4.5 kA(400 V) 4.5 kA Rated extreme short-circuit capacity (Icu): (230 V AC) 10 kA(400 V AC) 6 kA(230 V) 10 kA(400 V) 6 kA Rated conditional short-circuit current (Inc): (400 V) 6 kA Rated service short-circuit capacity (Ics): (230 V AC) 7.5 kA(400 V AC) 4.5 kA Nominal frequency (f): 50 / 60 Hz50 ... 60 Hz Loss of power: 5 Wa Nominal Operating Conditions for Polo 2.5 W Supply voltage connection: Arbitrary Contact position indication: ON / OFF

    €12,13

  • 2CSB204101R1400 | Abb DDA204 A-40/0.03

    ABB 2CSB204101R1400 | Abb DDA204 A-40/0.03

    Abb DDA204 A-40/0.03 2CSB204101R1400 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. GType of residual current: Type A Rated voltage (Ur): 230/400 VRated operating voltage: 230/400 VRated insulation voltage (Ui): 500 VImpulse withstand voltage ( Uimp): 4 kV Rated current (In): 40 ARated residual current: 30 mALeakage Current Type: ARated frequency (f): 50 … 60 Hz Power loss: 4.8 WSupply voltage connection: ArbitraryElectrical resistance: 10000 cycle(s) Number of poles: 4Operational characteristic: InstantaneousConnection capacity: Rigid 16 ... 16 mm²Flexible 16 ... 16 mm²

    €179,80

  • 4016779649728 | Abb S2C-A2L

    ABB 4016779649728 | Abb S2C-A2L

    A2L TRIP COIL 110-415V AC 4016779649728 The shunt coil is used to cause the remote opening of the switch to which it is associated by applying voltage. Technical dataFunction:Shunt TripPower loss:0 WEnvironmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019RoHS information:2CDK400627D2701REACH Declaration:9AKK107492A1906SCIP:4906475e-2b37-45cb-918c-db295dd155a2 Germany (DE)Conflict Minerals Reporting Template (CMRT) :9AKK108468A3363 DimensionsProduct width:17.5 mmProduct height:69 mmProduct depth:85 mmProduct net weight:0.14 kg

    €29,96

  • 1SDA066820R1 | Abb XT1B 160 TMD 160-1600 4p F F InN=50%

    ABB 1SDA066820R1 | Abb XT1B 160 TMD 160-1600 4p F F InN=50%

    Abb XT1B 160 TMD 160-1600 4p F F InN=50% 1SDA066820R1 TMAX XT1B 160 fixed four-pole circuit breaker with front terminals and TMD R 160-1600 thermomagnetic releases with neutral = 50% phases. Type of switch to be associated Power DistributionCable sections - main circuit Busbar 45.5 ... 80 mm²Type of current AC/DC Electrical life 120 cycles per hour8000 cycle (i)Mechanical life 240 cycles per hour25000 cycle (i) Number of poles 4Opening time CB with SOR 15 msCB with UVR 15 ms Multiple order 1 piece(s)Power loss at Nominal Operating Conditions for Polo 15 WMain product type SACE Tmax XTProduct name Molded case circuit breakerProduct type Automatic Circuit Breaker Rated current (In) 160 ARated frequency (f) 50 / 60 Hz Rated voltage (Ur) 690 VImpulse withstand voltage (Uimp) 8 kVRated instantaneous short-circuit current setting (Ii) 1600 ARated insulation voltage (Ui) 800 VRated operating voltage 690 V AC500 V DC

    €513,36

  • 2CSF202001R4250 | Abb F202 AC-25/0.5

    ABB 2CSF202001R4250 | Abb F202 AC-25/0.5

    Abb 500MA switch. differenti. pure 2CSF202001R4250 Pure RCDs without thermal-magnetic releases are switches that guarantee the protection of people from indirect contact. Technical data: Reference standards:IEC/EN 61008UL 1053Type of residual current:AC typeRated voltage (Ur):230 VRated operating voltage :230 VRated insulation voltage (Ui):500 VImpulse withstand voltage (Uimp):4 kVRated current (In):25 ARated residual current:500 mA Rated conditional short-circuit current (Inc):10 kARated service short-circuit capacity (Ics):1 kAMaximum Surge Current:0.25 kALeakage Current Type:ACFrequency nominal (f):50 … 60 HzPower loss:a Nominal Operating Conditions per Pole 1 WSupply voltage connection:ArbitraryElectrical resistance:10000 cycle (i)Number of poles :2Operating characteristic:Instant Mounting type: DIN-RailOptions Provided:NoneAccessories Available:YesConnection Capability:Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... . 55 °CAmbient temperature:In operation -25...55 °CDegree of protection:IP2XDegree of pollution:2Vibration resistance according to IEC 60068-2-6:0.1 mm or 1 g - 20 cycles at 5…150…5 HzShock resistance according to IEC 60068-2-27:25g 2 shocks 13 ms

    €78,58

  • 2CDS200922R0001 | Abb S2C-S/H6R

    ABB 2CDS200922R0001 | Abb S2C-S/H6R

    Abb Signaling/auxiliary contact 2CDS200922R0001 Signaling/auxiliary contact. Suitable for MCB S 200 series, SN 201 series (via SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical dataReference standards: CSA 22.2 No. 235GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function:Auxiliary / signaling contactSuitable for:S200S200MS200PS200SS300PSN201L+ SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Maximum 0.5 WNumber of auxiliary contacts NC:0Number of auxiliary contacts NO:0Number of auxiliary contacts c/o (SPDT):1Mounting position:right Environmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Information RoHS:9AKK108468A4564REACH Declaration:9AKK107492A1906SCIP:c151f68f-6fbb-44f7-badf-ba96efd56de4 Germany (DE)Conflict Minerals Reporting Template (CMRT):9AKK108468A3363 DimensionsProduct width:8.8 mmProduct height:85 mmProduct depth:69 mmProduct net weight:0.043 kg

    €24,14

  • 2CSM204703R1801 | Abb E 92/32 PV

    ABB 2CSM204703R1801 | Abb E 92/32 PV

    Abb E 92/32 PV 2CSM204703R1801  Designed for the protection and isolation of direct current circuits of photovoltaic systems up to 1000 V dc.Usage category DC-20B. Technical dataReference standards IEC 60947-3UL 4248-19 Rated voltage (Ur): 1000 VRated operating voltage: DC-20B 1000 V DCRated insulation voltage (Ui): 1 kVRated current ( In): 32 APower loss at Nominal Operating Conditions for Pole 3 WNumber of protected poles: 2Number of poles: 2Tightening torque: 2-2.5 N·m Usage category: DC-20BFuse type: gPVLock Type: Padlockable Mounting type: DIN-RailSeal type: Sealing Wire Material of Conductor: CopperOptions Provided: NoRecommended Screwdriver: Pozidriv 2

    €5,08

  • 2CDS274001R0105 | Abb S204M-B10

    ABB 2CDS274001R0105 | Abb S204M-B10

    Abb S204M-B10 S 204 M - B10 - 10kA Curve B 10A - 4P - B - 10 A 2CDS274001R0105 System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200. series differential blocks Technical dataReference standards: IEC/EN 60898-1CSA 22.2 No. 235IEC/EN 60947-2UL 1077Tripping characteristic:BRated operating voltage: according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 440 V AC Operating voltage: Maximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DCRated insulation voltage (Ui): according to IEC/ EN 60664-1 440 VImpulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kVDielectric test voltage: 50/60 Hz , 1 min: 2 kVType of input voltage: AC/DCRated current (In) 10 ARated short-circuit capacity: (AC) 10 kA(230 V AC) 10 kA(400 V AC) 10 kA(400 V) 10 kARated extreme short-circuit capacity (Icu): (230 V AC) 25 kA(400 V AC) 15 kA(440 V AC) 15 kA(230 V) 25 kA(400 V) 15 kARated conditional short-circuit current (Inc ): (230 V) 15 kA(400 V) 25 kA Rated service short-circuit capacity (Ics): (230 V AC) 7.5 kAFrequency (f): 50 HzRated frequency (f): 50 / 60 Hz50 ... 60 HzPower loss: 8.4 Wat Nominal Operating Conditions for Polo 2.1 W

    €121,05

  • a9a26946

    SCHNEIDER ELECTRIC A9A26946 | Schneider-Electric Release current launch

     Schneider-Electric Release. current throw iMX+OF 110/415Vac 110/130Vcc A9A26946 This Acti9 iMX+OF auxiliary electrical release for is a shunt release device with open/closed auxiliary contact. It is dedicated to Acti9 iC60, iID, iDPN Vigi, iSW-NA. This device includes an OF open/closed contact to indicate the location of the paired device. Presentationrange of productActi9Product typeRelease coil with open/closed contactDevice nameiMX+OFsignal contact composition1 A/CRated current [In]AC-12 3 A at 415 V , AC 50 HzAC-12 6 A at 100 V, AC 50 HzAC-12 6 A at 230 V, AC 50 HzDC-12 1 A at 110 V, DC DC-12 1 A at 130 V, DCControl voltage [Uc]100...415 V AC 50/60 Hz110...130 V DC9 mm pitch 2Technical characteristicsRange compatibilityActi9 -Acti9 Acti9 ARAActi9 -Acti9 Acti9 iIDActi9 Acti9 iSW -NAActi9 Acti9 RCAActi9 Acti9 iDPN (China version)Acti9 Acti9 iC60 two-terminal thermomagnetic switchActi9 Acti9 iC40Local signalingIndicator actionInstallationHookupInstallationDIN raildistribution comb compatibilityTop part: YESwidth18 mm ColorWhiteconnections - terminalsClip terminal - 2 cables 2.5 mm² - flexible with cable terminationClip terminal - 1 cable 6 mm² - rigidClip terminal - 2 cables 2.5 mm² - rigidClip terminal - 1 cable 4 mm² - flexibletightening torque 1 NmCompatibility codeIMX+OFEnvironmentReference standardsCEI EN 60947-5-1tropicalization2 compliant with CEI EN 60947-5-1relative humidity95 % at 55 °CAmbient temperature-25…50 °CStorage temperature-40…85 °C

    €43,51

  • A9Q41425 | Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block

    SCHNEIDER ELECTRIC A9Q41425 | Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block

    Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block A9Q41425 Acti9 Vigi iC60 is a modular additional residual current device. It is a 4P, rated current of 25A, operating voltage from 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 30 mA and voltage independent technology. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. A VisiTrip window is here to indicate a fault trip via a red mechanical indicator on the front. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of people and protection of installations. This product complies with IEC 61009-1 and EN 61009-1. The nominal operating voltage Ue is 400 V AC. The rated insulation voltage Ui is 500 V AC. The rated impulse withstand voltage Uimp is 6 kV. The pollution degree is 3. It can be mounted on DIN rail. Width in 9mm steps is 6. Dimensions are (W) 54mm x (H) 91mm x (D) 73.5mm. The weight is 0.245 kg. The degree of protection is IP20 and IP40 in a cabinet. The operating temperature is between -5°C and +60°C. The storage temperature is between -40°C and +85°C. Technical dataRangeActi9Product typeResidual current add-on devicesDevice nameVigi iC60Number of poles4PRated current [In]25 Adifferential sensitivity30 mAtiming differential protectionInstantEarth leakage protection typeAC typeNetwork type ACMains frequency50/60 HzRated operational voltage [Ue]400 V AC 50/ 60 Hz conforming to EN 61009-1400/415 V AC 50/60 Hz conforming to IEC 61009-1conforming to IEC/EN 61009-2-1Reference standardsIEC 61009-1EN 61009-1pitch 9 mm6device position in the systemStarting point residual current release technology"Voltage independent"Rated insulation voltage [Ui]500 V AC 50/60 Hz compliant with IEC 60947-2Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2Gamma compatibilityActi9 Acti9 iC60 Acti9 Acti9 Reflex iC60Product compatibilitySingle terminalLocal signalingTrip indicatorInstallationHookupInstallationDIN railelectrical connection to the circuit breakerPlug incomb compatibility distributionLower part: YESheight91 mmwidth54 mmdepth73.5 mmproduct weight0.245 kgconnections - terminalsBottom side cage terminal for 1 cable 1… 25 mm² rigid without cable endBottom side cage terminal for 1 cable 1…16 mm² flexible without cable endBottom side cage terminal for 1 cable 1…16 mm² flexible with cable end wire stripping length14 mm for lower part connectiontightening torque2 Nm lower part

    €188,34

  • A9P54610 | Schneider-electric iC40N 1P+N C 10A 6000A circuit breaker

    SCHNEIDER ELECTRIC A9P54610 | Schneider-electric iC40N 1P+N C 10A 6000A circuit breaker

    Schneider-electric Circuit breaker iC40N 1P+N C 10A 6000A A9P54610 This Acti9 iC40N product is a low voltage circuit breaker (MCB). It is a 1P+N switch with 1 protected pole and 10A rated current In and tripping curve C. The rated short-circuit breaking capacity reaches up to 10kA at 230VAC in compliance with the EN/IEC 60947-2 standard and 6000A at 230VAC in compliance with EN/IEC 60898-1. This product complies with industrial standards EN/IEC 60898-1 and residential standards EN/IEC 60947-2. This circuit breaker combines the functions of circuit protection against short circuits and overload current, control and isolation. Installation and wiring are simplified with clip-on functionality and easy maintenance. Technical dataRangeActi9Product nameActi9 iC40Product typeSwitch modularDevice nameiC40NApplicationDistributionNumber of poles1P + Nnumber of protected poles1neutral positionLeftRated current [In]10 AType of networkCARelease technologyMagnetothermalcurve codeCSwitching capacity10 kA Icu compliant with EN/IEC 60947-2 at 230 V AC 50/60 Hz6000 A Icn compliant with CEI EN 60898-1 at 230 V AC 50/60 Hz Aptitude for sectioningComplies with EN/IEC 60947-2quality marksAENOROVEIMQ RCMTechnical characteristicsMains frequency50/60 HzRated operational voltage [Ue]230 V AC 50/60 Hzmagnetic release limit5...10 x In conforming to CEI EN 60898-18 x In +/- 20 % conforming to EN/IEC 60947-2 Rated service breaking capacity [Ics]6000 A 100 % Icn at 230 V AC 50/60 Hz compliant with CEI EN 60898-17.5 kA 75 % Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2limitation class3 conforming to CEI EN 60898-1Rated insulation voltage [Ui]400 V AC 50/60 Hz conforming to EN/IEC 60947-2Rated impulse withstand voltage [Uimp]4 kV conforming to EN /IEC 60947-2contact position signalingYesType of controlLeverLocal signalingON/OFF indicationSnap indicatorInstallationAttachmentInstallationDIN rail9 mm pitch2height85 mmwidth18 mmdepth74 mm product weight120 gColorWhiteMechanical durability20000 cycleselectrical life20000 cyclesDescription of locking optionsPadlock deviceconnections - terminalsTop part cage terminals or lower1…10 mm² flexibleCage terminals upper or lower part1…16 mm² rigidwire stripping length14 mm for upper or lower part connectionpair tightening pressure2 Nm upper or lower partdifferential protectionSeparate block  

    €46,04


© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • Amazon
    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account