Technical data

Reference standards IEC EN 60947-2 Ann M
Type of residual current Type A
Function For mixed system

Rated voltage (Ur) 400...400 V
Rated operating voltage 230 ... 400 V AC
Voltage nominal control power supply (Us) (50 Hz) 400...400 V
(60 Hz) 400...400 V

Rated current Response value amperage 1 500 ... 500 mA
Rated frequency (f) 50 … 60 Hz
Loss of power 3.6 W

Number of contacts 2
Number of c/o contacts 1
Number of NC contacts 0
Number of NO contacts 0
Delay time (τ) Delay-On Energization, Maximum, Permitted 10 second [time unit]
Delay-On Energization, Minimum, Adjustable 0 second [time unit]

Mounting type DIN rail
Filter option no frequency filter
Options provided Pre-alarm threshold: no

Product form

Abb RD3 2CSJ201001R0002  The differential relays with external toroidal transformer allow protection against earth faults. Using the minidip it is possible... Read more

SKU: J427348
Barcode: 8012542734833

IN STOCK

IT €240,40
€197,05 Excl. VAT

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 85389091
    Icon for cloud_dataSPECIFICATIONS

    • Tipo di collegamento elettrico - Connessione a vite
    • Con morsetti estraibili - no
    • Funzione - Per reti miste
    • Tipo di tensione di alimentazione - AC
    • Tensione di alimentazione in corrente alternata (AC) 50 Hz - 230...400 V

    Icon for verifiedDOCUMENTATION
    Icon for coinCUSTOM QUOTE

    Our Sales Team will be at your disposal.

    Send us a message!

    Description

    Abb RD3 2CSJ201001R0002 

    The differential relays with external toroidal transformer allow protection against earth faults. Using the minidip it is possible to adjust the sensitivity and the intervention time.

    Technical data

    Reference standards IEC EN 60947-2 Ann M
    Type of residual current Type A
    Function For mixed system

    Rated voltage (Ur) 400...400 V
    Rated operating voltage 230 ... 400 V AC
    Voltage nominal control power supply (Us) (50 Hz) 400...400 V
    (60 Hz) 400...400 V

    Rated current Response value amperage 1 500 ... 500 mA
    Rated frequency (f) 50 … 60 Hz
    Loss of power 3.6 W

    Number of contacts 2
    Number of c/o contacts 1
    Number of NC contacts 0
    Number of NO contacts 0
    Delay time (τ) Delay-On Energization, Maximum, Permitted 10 second [time unit]
    Delay-On Energization, Minimum, Adjustable 0 second [time unit]

    Mounting type DIN rail
    Filter option no frequency filter
    Options provided Pre-alarm threshold: no

    • Warranty

      Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • <tc>Telephone</tc>

      Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT 04742820618

    DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

      • Amazon
      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account