2CDS242701R0164 | Abb S202L-C16

Description

Abb S202L-C16 2CDS242701R0164

The System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200 series differential blocks.

Technical data

  • Reference standards:
    IEC/EN 60898-1
    IEC/EN 60947-2
  • Trip characteristic:
    C
  • Rated operating voltage:
    according to IEC 60898-1 400 V AC
    according to IEC 60898-1 400 V
    according to IEC 60947-2 400 V AC
  • Operating voltage:
    Maximum (Incl. Tolerance) 440 V AC
    Minimum 12 V AC
  • Rated insulation voltage (Ui):
    according to IEC/EN 60664-1 440 V
  • Impulse withstand voltage (Uimp):
    4 kV
    at 2000 m 5 kV
    at Sea Level 6.2 kV
  • Dielectric test voltage:
    50/60 Hz, 1 min: 2 kV
  • Input voltage type:
    AC
  • Rated current (In):
    16 A
  • Short-circuit rating:
    (AC) 4.5 kA
    (DC) 4.5 kA
    (400 V AC) 4.5 kA
    (400 V) 4.5 kA
  • Rated extreme short-circuit capacity (Icu):
    (230 V AC) 10 kA
    (400 V AC) 6 kA
    (230 V) 10 kA
    (400 V) 6 kA
  • Rated conditional short-circuit current (Inc):
    (400 V) 6 kA
  • Rated service short-circuit capacity (Ics):
    (230 V AC) 7.5 kA
    (400 V AC) 4.5 kA
  • Nominal frequency (f):
    50 / 60 Hz
    50 ... 60 Hz
  • Loss of power:
    5 W
    a Nominal Operating Conditions for Polo 2.5 W
  • Supply voltage connection:
    Arbitrary
  • Contact position indication:
    ON / OFF

2CDS242701R0164 | Abb S202L-C16

Product form

SKU: S598484
Barcode: 4016779598484

€13,95

  •  Made to order - Delivery in 2-6 weeks
  • HS CODE: 85389091
  • STANDARD RETURN
  • QUICK DELIVERY ASSURED
  DELIVERY TIMES

The delivery times for goods in the “AVAILABLE” status are usually 1 to 3 working days: the products are available in our main warehouse, ready for delivery for the quantity indicated, and the times required are those of shipping via express carrier and vary according to the destination.

The delivery times for goods in the “AVAILABLE EU WAREHOUSE” status are usually 3 to 5 working days and subject to unforeseeable variations.

The delivery times for goods in the “MADE TO ORDER” status are usually 2-6 weeks: contact our sales team for a precise indication

  DOCUMENTATION

Description

Abb S202L-C16 2CDS242701R0164

The System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200 series differential blocks.

Technical data

  • Reference standards:
    IEC/EN 60898-1
    IEC/EN 60947-2
  • Trip characteristic:
    C
  • Rated operating voltage:
    according to IEC 60898-1 400 V AC
    according to IEC 60898-1 400 V
    according to IEC 60947-2 400 V AC
  • Operating voltage:
    Maximum (Incl. Tolerance) 440 V AC
    Minimum 12 V AC
  • Rated insulation voltage (Ui):
    according to IEC/EN 60664-1 440 V
  • Impulse withstand voltage (Uimp):
    4 kV
    at 2000 m 5 kV
    at Sea Level 6.2 kV
  • Dielectric test voltage:
    50/60 Hz, 1 min: 2 kV
  • Input voltage type:
    AC
  • Rated current (In):
    16 A
  • Short-circuit rating:
    (AC) 4.5 kA
    (DC) 4.5 kA
    (400 V AC) 4.5 kA
    (400 V) 4.5 kA
  • Rated extreme short-circuit capacity (Icu):
    (230 V AC) 10 kA
    (400 V AC) 6 kA
    (230 V) 10 kA
    (400 V) 6 kA
  • Rated conditional short-circuit current (Inc):
    (400 V) 6 kA
  • Rated service short-circuit capacity (Ics):
    (230 V AC) 7.5 kA
    (400 V AC) 4.5 kA
  • Nominal frequency (f):
    50 / 60 Hz
    50 ... 60 Hz
  • Loss of power:
    5 W
    a Nominal Operating Conditions for Polo 2.5 W
  • Supply voltage connection:
    Arbitrary
  • Contact position indication:
    ON / OFF
  • Warranty

    12 month warranty. For more information visit Termini e Condizioni

  • Return Policy

    Standard. For more information visit Terms and Conditions

  • E-mail

    Contact us via email sales@dmstechmart.com and we will try to respond to you as soon as possible

Recently viewed products

    Footer image

    © 2025 DMS S.R.L. VAT IT04742820618