DIRECT CURRENT POWER SUPPLIES
-
SIEMENS 6EP33326SB000AY0 |
Siemens logo!Power 24 V / 2.5 ASiemens logo!Power 24 V / 2.5 A 6EP33326SB000AY0 Astabilized power supply input: AC 100 ... 240 V output: DC 24 V / 2.5 A. Technical data Inputform of the electrical network: Single-phase AC or DCsupply voltage with AC rated value min./max.: 100 ... 240 Vsupply voltage with AC start/end value: 85 ... 264 Vinput voltage with DC: 110 ... 300 Vwide-range input: Yesoverloadability due to overvoltage: AC 300 V for 1 s buffering time with nominal value of the output current in case of mains voltage failure min.: 40 msbuffering operating condition for mains voltage failure:With Ue = 187 Vpower frequency: 50/60 Hzpower frequency start/end value: 47 ... 63 Hzinput current● at nominal value of the 120 V input voltage: 1.22 A● at nominal value of the input voltage 230 V: 0.66 Acurrent limitation of the inrush current at 25 °C max.: 52 AI2t value max.: 3 A²·s Outputshape of the voltage curve at the output: potential-free regulated DC voltageoutput voltage with DC nominal value: 24 Voutput voltage ● at output 1 with DC rated value: 24 Vsettable output voltage: Yes; Via potentiometersettable output voltage initial value: 22.2 Vsettable output voltage final value: 26.4 Vrelative overall voltage tolerance: 3 %relative voltage regulation accuracy output voltage● with slow fluctuation of the input voltage: 0.1 %● with slow fluctuation of the ohmic load: 0.1 %
€52,46
-
SIEMENS 6EP13341LB00 | Siemens sitop PSU100L 24V/10A
Siemens sitop PSU100L 24 V/10 A 6EP13341LB00 Stabilized power supply input: AC 120/230 V output: DC 24 V/10 A. Technical data Inputform of the electrical network Single-phase ACsupply voltage with AC Setting via switch on the devicesupply voltage 120 V/230 V input voltage 1 at 93 ... 132 V ACinput voltage 2 at 187 ... 264 V ACwide-range input Nooverloadability due to overvoltage 2.3 x Ue nom, 1, 3 msbuffering time with nominal value of theoutput current in case of lack of mains voltage min.20 msbackup operating condition for lack ofmains voltage With Ue = 93/187 Vmains frequency 50/60 Hzmains frequency initial valuemains frequency final value47 ... 63 Hzmains current input● at rated input voltage 120 V 4.1 A● at rated input voltage 230 V 2 Acurrent limitation of the inrush current to 25 °C max. 65 Aduration of inrush current limitation at 25 °C● typ. 3 msI2t value max. 3.3 A²·simplementation of protection T 6.3 A/250 V (not accessible)implementation of mains cable protection Recommended circuit breaker: apart. from 10 A characteristic COutputshape of the voltage curve at the output regulated potential-free DC voltageoutput voltage with DC nominal value 24 Voutput voltage ● at output 1 with nominal value DC 24 Voutput voltage adjustable Yes; Via potentiometersettable output voltage initial value 22.8 Vsettable output voltage final value 26.4 Vrelative overall voltage tolerance 3 %relative regulation accuracy of the output voltage● with slow fluctuation of the input voltage 0.1 %● with slow fluctuation of the ohmic load 0.5 %residual ripple● max. 150 mV● typ. 50 mV
€84,20
-
SIEMENS 6EP33316SB000AY0 |
Siemens logo!power 24 V / 1.3 ASiemens logo!power 24 V / 1.3 A 6EP33316SB000AY0 Stabilized power supply input: AC 100 ... 240 V output: DC 24 V / 1.3 A. Technical data Inputform of the electrical network: Single-phase AC or DCsupply voltage with AC nominal value min./max.: 100 ... 240 V supply voltage with AC start/stop value: 85 ... 264 Vinput voltage with DC: 110 ... 300 Vwide-range input: Yesoverloadability due to overvoltage: AC 300 V for 1 sbuffering time with nominal value of the output current in case of mains voltage failure min.: 40 msbuffering operating condition for mains voltage failure: With Ue = 187 Vmains frequency: 50/60 Hzmains frequency start/end value: 47 ... 63 Hzinput current● at rated input voltage 120 V: 0.7 A● at nominal value of the input voltage 230 V: 0.35 Acurrent limitation of the inrush current at 25 °C max.: 25 AI2t value max.: 0 .8 A²·s Outputshape of the voltage curve at the output: potential-free regulated DC voltageoutput voltage with DC nominal value: 24 Voutput voltage ● at output 1 with DC rated value: 24 Vsettable output voltage: Yes; Via potentiometersettable output voltage initial value: 22.2 Vsettable output voltage final value: 26.4 Vrelative overall voltage tolerance: 3 %relative voltage regulation accuracy output voltage● with slow fluctuation of the input voltage: 0.1 %● with slow fluctuation of the ohmic load: 0.1 %
€45,01
-
SCHNEIDER ELECTRIC ABL8RPS24050 | Schneider-Electric universal power supply
Schneider-Electric universal power supply ABL8RPS24050 The Schneider Electric ABL8 regulated switching mode power supply provides direct current voltage, has a rated input of 100 to 500 Vac, a rated output current of 5 A at 24 Vdc and a rated power of 120 watts. PresentationProduct rangeModicon Power SupplyProduct typePower supplypower supply type Switching modeNominal input voltage100...120 V AC single phase, terminals: N-L1200...500 V AC phase to phase, terminals: L1-L2rated power in W 120 Woutput voltage 24 V DCoutput power supply current 5 Aadmissible temporary current amplification 1.5 x In (for 4 s)anti-harmonic filterLow frequency harmonic currentsTechnical characteristicsinput voltage limits85...132 V AC170...550 V ACinput current inrush 30 A18 mm modules0.51 at 240 V AC0.59 at 120 V ACefficiency 87 %Output voltage adjustment24...28, 8 V adjustablepower dissipated in W 15.5 WEquipment suppliedCorrector filter power factor compliant with IEC 61000-3-2output protection type Against overload, protection technology: manual or automatic resetAgainst overvoltage, protection technology: 30...32 V, manual resetAgainst short circuits, protection technology: manual or automatic resetAgainst undervoltage, protection technology: intervention with U Thermal, protection technology: automatic resetConnections - terminalsRemovable screw terminal block: 2 x 2.5 mm², for diagnostic relayScrew terminal blocks: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connectionScrew terminal blocks: 1 x 0.5... 1 x 4 mm², (AWG 22...AWG 12) for input earth connectionScrew terminal blocks: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connectionScrew terminal blocks: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output grounding connectionStatus LED1 LED (green and red) output voltage1 LED (green, red and orange) output currentdepth125 mmheight143 mmwidth56 mm product weight0.7 kgoutput connectionParallelSeries
€206,12
-
SCHNEIDER ELECTRIC ABLM1A24012 | Schneider Electric Switching power supplies
Schneider Electric Switching power supplies, 100-240 V AC, 24 V 1.2 A, single phase, Modular ABLM1A24012 The ABLM regulated switching power supply (SMPS) provides direct current voltage. It has a rated input of 100V to 240V AC, a rated output current of 1.25A at 24V DC, and a rated power output of 30W. It is ideal for providing the DC voltage needed for automation equipment designed for industrial applications , commercial and residential. Examples: transportation, packaging, inspection, food and beverage, mining, oil and gas, and water. It is installed on an omega rail or fixed with a screw. Dimensions: Width 36mm, Height 91mm, Depth 55.6mm. Provides protection against overloads and short circuits with automatic restart after correction of the overload/short circuit source. Weight: 0.170kg. It is a rail mount industrial power supply. It complies with EN62368-1, ENIEC61010-1/2-201, ENIEC61204-3, EN61000-6-1/2/3/4, EN61000-3-2-3, UL62368-1, UL61010-2-201/ -1-201, CSAC22.2No62368-1/No61010-2-201/No61010-1. The product is CE, CUL, RCM and CB Scheme certified. The Acti9 iC60 range of miniature circuit breakers is recommended for its protection. The type of protection is 4A, curve B or C. On the front there is an LED indicating the presence of DC output voltage and a QR code for access to the latest technical documentation. Thanks to their modular housing, they can be installed in industrial enclosures or panels by clip fixing on an omega (DIN) rail. Provides energy to automated systems. Designed for simple machines and applications, modular power supplies are appreciated above all for their extreme compactness. Product Range Modicon Power SupplyProduct Type Power SupplyPower Supply Type Switching ModeVariant Option ModularMaterial Cassette PlasticNominal Input Voltage 100...240 V AC single phase100...240 V AC phase to phase Rated Power In W 30 WOutput Voltage 24 V DCOutput Power Supply Current 1.25 AVoltage Limits In Input 90...264 V ACNominal Network Frequency 50…60 HzMaximum Leakage Current 0.25 mA 240 V ACType of Protection Input Integrated fuse (not replaceable) 3.15 AExternal protection (recommended) 20 A Curve BExternal protection (recommended) 20 A Curve CExternal protection (recommended) ) 4 A Curve BExternal protection (recommended) 4 A Curve CInrush Current 25 A at 115 V50 A at 230 VModules 18 mm 0.48 at 115 V AC0.38 at 230 V ACEfficiency 87 % at 115 V AC87 % at 230 V ACOutput Voltage Adjustment 24...28 V
€90,53
-
SCHNEIDER ELECTRIC ABL8RPS24030 | Schneider-Electric Universal power supply
Schneider-Electric Universal power supply ABL8RPS24030 The Schneider Electric ABL8 regulated switching mode power supply provides direct current voltage, has a rated input of 100 to 500 Vac, a rated output current of 3 A at 24 Vdc and a rated power of 72 watts. PresentationProduct rangeModicon Power SupplyProduct typePower supplypower supply typeSwitching modeNominal input voltage100...120 V AC single phase, terminals: N-L1200...500 V AC phase to phase, terminals: L1-L2nominal power in W 72 Woutput voltage 24 V DCoutput power supply current 3 Aadmissible temporary current amplification1.5 x In (for 4 s)anti-harmonic filterCurrents low frequency harmonicsTechnical characteristicsinput voltage limits170...550 V AC85...132 V ACInrush current30 A18 mm modules0.51 at 240 V AC0.59 at 120 V ACefficiency87 %Output voltage adjustment24.. .28.8 V adjustablepower dissipation in W 7.8 WEquipment suppliedPower factor corrector filter compliant with IEC 61000-3-2output protection type Against overload, protection technology: manual or automatic resetAgainst overvoltage, protection technology: 30...32 V, manual resetAgainst short circuits, protection technology: manual or automatic reset Against undervoltage, protection technology: intervention with U Thermal, protection technology: automatic resetconnections - terminalsScrew terminal blocks: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connectionScrew terminal blocks: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input earth connection Screw terminal blocks: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connectionScrew terminal blocks: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output ground connectionStatus LED1 LED (green and red) output voltage1 LED (green, red and orange) current outputdepth125 mmheight125 mmwidth45 mmproduct weight0.3 kgoutput connectionParallel
€158,61
-
SCHNEIDER ELECTRIC ABLM1A24025 | Schneider-Electric 24V 2.5A modular power supply
Schneider-Electric 24V 2.5A modular power supply ABLM1A24025 The ABLM regulated switching power supply (SMPS) provides direct current voltage. It has a rated input of 100V to 240V AC, a rated output current of 2.5A at 24V DC and a rated power output of 60W. It is ideal for providing the DC voltage needed for automation equipment designed for industrial applications , commercial and residential. PresentationProduct rangeModicon Power SupplyProduct typePower supplypower supply typeSwitching modeVariant optionModularNominal input voltage100...240 V AC single phase100...240 V AC phase to phasenominal power in W 60 Woutput voltage 24 V DCoutput power supply current 2.5 ATechnical characteristicsinput voltage limits90...264 V ACInput protection typeIntegrated fuse (non-replaceable) 3.15 AExternal protection (recommended) 20 A Curve BExternal protection (recommended) 20 A Curve CExternal protection (recommended) 10 A Curve BExternal protection (recommended) 6 A Curve CInrush current30 A at 115 V60 A at 230 V18 mm modules0.50 at 115 V AC0.39 at 230 V ACefficiency90 % at 115 V AC90 % at 230 V ACpower dissipated in W 6.5 Wcurrent absorptionTurn-on time Holding time> 20 ms 115 V AC> 60 ms 230 V ACStartup with capacitive loads3000 µFresidual ripplemean time between failures (MTBF)1300000 H at 25 °C, full load700000 H at 55 °C, 80 % loadoutput protection type Against overload and short circuits, protection technology: automatic resetAgainst over temperature, protection technology: manual resetAgainst overvoltage, protection technology: manual resetconnections - terminalsConnection to screw: 0.5...2.5 mm², (AWG 20...AWG 14) without wire end ferrule for outputScrew connection: 0.5...1.5 mm², (AWG 20. ..AWG 16) with wire end ferrule for outputScrew connection: 0.5...1.5 mm², (AWG 20...AWG 16) for inputline and load regulation Status LED1 LED (green) output voltagedepth55.6 mmheight 91 mmwidth53 mmproduct weight0.221 kgoutput connectionSerialParallelmounting supportTop hat type TH35 -15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715Double profile DIN railpanel mountingpower supplySELV conforming to IEC 60950-1 SELV compliant with IEC 60204-1SELV compliant with IEC 60364-4-41dielectric strength3000 V AC input / output
€112,74
-
SCHNEIDER ELECTRIC ABL8RPM24200 | Schneider Electric Power supply with comm. regulated
Schneider Electric Power supply with comm. regulated - 1 or 2 phases - 100..240 V AC - 24 V - 20 A ABL8RPM24200 PresentationProduct rangeModicon Power SupplyProduct typePower supplypower supply typeSwitching modeNominal input voltage100...120 V AC single phase, terminals: N-L1200...240 V AC phase to phase, terminals: L1-L2nominal power in W480 Woutput voltage24 V DCoutput power supply current20 Aadmissible temporary current amplification1.5 x In (for 4 s )anti-harmonic filterLow frequency harmonic currentsTechnical characteristicsinput voltage limits85...132 V AC170.. .264 V ACinrush current30 A18 mm modules0.68 at 240 V AC0.69 at 120 V ACefficiency88 % Output voltage adjustment24...28.8 V adjustablepower dissipated in W57.6 Wequipment suppliedPower factor corrector filter compliant with IEC 61000-3-2output protection typeAgainst overload, protection technology: manual or automatic resetAgainst overvoltage, protection technology: 30...32 V, manual resetAgainst short circuits, protection technology: manual or automatic resetAgainst undervoltage, protection technology: tripping with U Thermal, protection technology: automatic reset connections - terminalsRemovable screw terminal block: 2 x 2.5 mm², for diagnostic relayScrew terminal blocks: 3 x 0.5...3 x 4 mm², (AWG 22 ...AWG 12) for input connectionScrew terminal blocks: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input earth connectionTerminal blocks screw: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connectionStatus LED1 LED (green and red) output voltage1 LED (green, red and orange) output currentdepth145 mmheight125 mmwidth146 mmproduct weight1.6 kg output connectionSeriesParallelmarkingCEmounting support35 x 7.5 mm symmetrical DIN rail35 x 15 mm symmetrical DIN railoperating positionVerticalpower supplySELV conforming to IEC 60950-1SELV conforming to IEC 60204-1SELV conforming to IEC 60364-4-41 dielectric resistance2500 V with between input and ground insulation3000 V with between input and output insulation500 V with between output and ground insulation
€187,99
-
SIEMENS 6EP13342BA20 | Siemens Sitop PSU100S 24V/10A
SIEMENS SITOP PSU100S 24 V/10 A 6EP13342BA20 SITOP PSU100S 24 V/10 A stabilized power supply input: AC 120/230 V output: DC 24 V/10 A. General information: Entrance: Form of the electrical network Single-phase ACsupply voltage at AC● initial value Automatic range switchingsupply voltage● 1 at AC rated value 120 V ● 2 with AC 230 V rated valueinput voltage● 1 with AC 85 ... 132 V● 2 with AC 170 ... 264 Vinput design wide input range Nooverloadability due to overvoltage 2.3 x Ue nom, 1.3 msbackup operating condition due to lack ofmains voltage With Ue = 93/187 Vbackup time with rated value of theoutput current in case of mains voltage failure min. 20 msbackup operating condition due to lack of mains voltage With Ue = 93/187 Vmains frequency● 1 nominal value 50 Hz● 2 value rated 60 Hzmains frequency 47 ... 63 Hzinput current● at rated input voltage 120 V 4.49 A● at rated input voltage 230 V 1.91 Acurrent limitation of the inrush current at 25 °C max. 60 AI2t value max. 5.6 A²·sexecution of protection T 6.3 A/250 V (not accessible)● of the mains cable Recommended circuit breaker: apart. from 10 A characteristic COutputshape of the voltage curve at the output regulated potential-free DC voltageoutput voltage with DC rated value 24 V output voltage ● at output 1 with DC nominal value 24 Vrelative overall voltage tolerance 3 %relative control accuracy of the output voltage● with slow fluctuation of the input voltage 0.1 % ● with slow ohmic load fluctuation 1 %residual ripple● max. 150 mV● typ. 20 mVpeak voltage● max. 240 mV● typ. 160 mVoutput voltage adjustable 22.8 ... 28 Vproduct function output voltage adjustable Yestype of setting of the output voltage Via potentiometerdisplay execution for normal operation LED green for 24 V O.K.type of signal at the output Relay contact (open contact, loadability DC 60 V/0.3 A) for "24 V O.K."progression of the output voltage at switch-on Overshoot of Ua max. intervention delay 0.3 svoltage rise time of the output voltage● typ. 20 msoutput current● rated value 10 A● rated range 0 ... 12 A; 12 A ... +45 °C; +60 ... +70 °C: Derating 3%/Kexported active power typ. 288 Wshort-time overload current● in case of short circuit during normal starting typ. 32 A● in the event of a short circuit during typical operation. 32 Aduration of overloadability due to overcurrent● in case of short circuit during start-up 1 000 ms● in case of short circuit during operation 1 000 msproduct characteristic● parallel connection of equipment Yesnumber of equipment connected in parallel for power increase2Efficiencyefficiency [%] 90 %power dissipated [W]● with nominal value of the output voltage with nominal valueof the output current typ. 25 WRegulationrelative regulation accuracy of the output voltage withrapid input voltage fluctuation of +/- 15 % typ.0.3 %relative regulation accuracy of the output voltage withstep variation of the ohmic load 10/90/10 % typ. 3 %
€145,08
-
SIEMENS 6EP13343BA10 | SITOP PSU200M Stabilized Power Supply Input
SIEMENS SITOP PSU200M 10A 6EP13343BA10 SITOP PSU200M 10 A stabilized power supply input: AC 120/230 ... 500 V output: DC 24 V/10 A *Ex approval no longer available* EntranceSingle-phase and two-phase AC electrical network shapesupply voltage with AC● Initial value Setting by switch on the devicesupply voltage● 1 with AC 120 ... 230 V● 2 with AC 230 ... 500 Vinput voltage● 1 with AC 85 ... 264 V● 2 with AC 176 ... 550 VInput execution wide-range input YesOvervoltage overload capability 1300 Vpeak, 1.3 msoperating condition of the buffer due to lack ofmains voltageWith Ue = 120/230 V, typ. 150 ms with Ue = 400 Vbuffering time with nominal current valueoutput in case of mains voltage failure min.25 msoperating condition of the buffer due to lack ofmains voltageWith Ue = 120/230 V, typ. 150 ms with Ue = 400 Vnetwork frequency● 1 nominal value 50 Hz● 2 nominal value 60 HzMains frequency 47 ... 63 Hzinput current● with input voltage rating 120V 4.4A● with input voltage rating 230 V 2.4 A● with input voltage rating 500V 1.1Acurrent limitation of the inrush current at 25 °C max. 35 AI2t value max. 4 A² sexecution of protection T 6.3 A (not accessible)● of the network cable Circuit breaker recommended for single-phase operation: apart.from 6 A (10 A) characteristic C (B); required for two-phase operation:magnetothermal switch with bipolar coupling or switchautomatic 3RV2011-1EA10 (set to 3.8 A) or 3RV2711-1ED10 (UL489) with 230 V, 3RV2011-1DA10 (setting to 3 A) or 3RV2711-1DD10(UL 489) with 400/500 VExitshape of the voltage curve at the output of the regulated DC voltage at free potentialOutput voltage with DC nominal value 24 Voutput voltage● on output 1 with DC nominal value 24 Voverall relative voltage tolerance 3 %relative regulation accuracy of the output voltage● with slow fluctuation of input voltage 0.1%
€175,15
-
SIEMENS 6EP13333BA10 | Siemens Sitop PSU200M 5 A
SIEMENS SITOP PSU200M 5 A 6EP13333BA10 SITOP PSU200M 5 A stabilized power supply input: AC 120/230 ... 500 V output: DC 24 V/5 A *Ex approval no longer available* Inputform of the electrical network Single-phase and two-phase ACsupply voltage with AC● initial value Setting via switch on the equipment; start from EU >90/180 V supply voltage● 1 at AC 120 ... 230 V● 2 at AC 230 ... 500 V input voltage● 1 at AC 85 ... 264 V● 2 at AC 176 ... 550 V input implementation wide-range input Yesoverload capability for overvoltage 1300 Vpeak, 1.3 ms backup operating condition due to lack of mains voltageWith Ue = 120/230 V, typ. 150 ms with Ue = 400 Vbuffering time with nominal value of the output currentin case of mains voltage failure min. 25 ms backup operating condition due to lack ofmains voltageWith Ue = 120/230 V, typ. 150 ms with Ue = 400 V mains frequency● 1 nominal value 50 Hz● 2 nominal value 60 Hzmains frequency 47 ... 63 Hz input current● at rated input voltage 120 V 2.2 A● at rated input voltage 230 V 1, 2 A● at nominal value of the input voltage 500 V 0.61 Acurrent limitation of the inrush current at 25 °C max. 35 AI2t value max. 1.7 A²·s execution of protection T 3.15 A (not accessible)● of the mains cable Recommended thermomagnetic switch for single-phase operation: separately from 6 A (10 A) characteristic C (B); required for two-phase operation:thermic circuit breaker with bipolar coupling or automaticbreaker 3RV2011-1EA10 (setting to 3.8 A) or 3RV2711-1ED10 (UL489) with 230 V, 3RV2011-1DA10 (setting on 3 A) or 3RV2711-1DD10(UL 489) with 400/500 VOutputshape of the voltage curve at the output regulated potential-free direct voltage Output voltage with DC rated value 24 V output voltage● at output 1 with DC nominal value 24 Vrelative overall voltage tolerance 3 %relative control accuracy of output voltage
€161,20
-
PEPPERL+FUCHS 283674 | Pepperl+Fuchs transmitter power supply KFD2-STC4-Ex1.2O
PEPPERL+FUCHS TRANSMITTER POWER SUPPLY KFD2-STC4-Ex1.2O 283674 Functions: This isolating barrier is used for intrinsic safety applications. The device supplies power to 2-wire and 3-wire SMART transmitters in a hazardous area and can also be used with 2-wire SMART power sources. Transfers the analog input signal to the safe area as an isolated current value. Digital signals can be superimposed on the input signal in the dangerous or safe area and are transferred in both directions. If the HART communication resistance in the circuit is too low, the internal 250 Ω resistor between terminals 8 and 9 can be used. Test sockets for connecting HART communication devices are integrated into the device terminals. Applications The device supports the following SMART protocols: HART BRAIN Foxboro
€619,90