6EP13342BA20 | Siemens Sitop PSU100S 24V/10A

Description

SIEMENS SITOP PSU100S 24 V/10 A 6EP13342BA20

SITOP PSU100S 24 V/10 A stabilized power supply input: AC 120/230 V output: DC 24 V/10 A.

General information:

Entrance:

Form of the electrical network Single-phase AC
supply voltage at AC
● initial value Automatic range switching
supply voltage
● 1 at AC rated value 120 V
● 2 with AC 230 V rated value
input voltage
● 1 with AC 85 ... 132 V
● 2 with AC 170 ... 264 V
input design wide input range No
overloadability due to overvoltage 2.3 x Ue nom, 1.3 ms
backup operating condition due to lack of
mains voltage With Ue = 93/187 V
backup time with rated value of the
output current in case of mains voltage failure min. 20 ms
backup operating condition due to lack of mains voltage             
With Ue = 93/187 V
mains frequency
● 1 nominal value 50 Hz
● 2 value rated 60 Hz
mains frequency 47 ... 63 Hz
input current
● at rated input voltage 120 V 4.49 A
● at rated input voltage 230 V 1.91 A
current limitation of the inrush current at 25 °C max. 60 A
I2t value max. 5.6 A²·s
execution of protection T 6.3 A/250 V (not accessible)
● of the mains cable Recommended circuit breaker: apart. from 10 A characteristic C
Output
shape of the voltage curve at the output regulated potential-free DC voltage
output voltage with DC rated value 24 V output voltage
● at output 1 with DC nominal value 24 V
relative overall voltage tolerance 3 %
relative control accuracy of the output voltage
● with slow fluctuation of the input voltage 0.1 %
● with slow ohmic load fluctuation 1 %
residual ripple
● max. 150 mV
● typ. 20 mV
peak voltage
● max. 240 mV
● typ. 160 mV
output voltage adjustable 22.8 ... 28 V
product function output voltage adjustable Yes
type of setting of the output voltage Via potentiometer
display execution for normal operation LED green for 24 V O.K.
type of signal at the output Relay contact (open contact, loadability DC 60 V/0.3 A) for "24 V O.K."
progression of the output voltage at switch-on Overshoot of Ua < 3 %
max. intervention delay 0.3 s
voltage rise time of the output voltage
● typ. 20 ms
output current
● rated value 10 A
● rated range 0 ... 12 A; 12 A ... +45 °C; +60 ... +70 °C: Derating 3%/K
exported active power typ. 288 W
short-time overload current
● in case of short circuit during normal starting typ. 32 A
● in the event of a short circuit during typical operation. 32 A
duration of overloadability due to overcurrent
● in case of short circuit during start-up 1 000 ms
● in case of short circuit during operation 1 000 ms
product characteristic● parallel connection of equipment Yes
number of equipment connected in parallel for power increase
2
Efficiency
efficiency [%] 90 %
power dissipated [W]
● with nominal value of the output voltage with nominal value
of the output current typ. 25 W
Regulation
relative regulation accuracy of the output voltage with
rapid input voltage fluctuation of +/- 15 % typ.0.3 %
relative regulation accuracy of the output voltage with
step variation of the ohmic load 10/90/10 % typ. 3 %

Product form

IN STOCK

SKU: 6EP1334-2BA20
Barcode: 4025515153498

€236,55

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 85044090
      SPECIFICATIONS

    • Tipo di tensione di alimentazione - AC
    • Tensione di uscita 1 - 24...24 V
    • Max. corrente di uscita 1 - 12 A
    • Tensione di uscita regolabile - sì
    • Valore nominale tensione d'uscita 1 - 24 V

      DOCUMENTATION

    Description

    SIEMENS SITOP PSU100S 24 V/10 A 6EP13342BA20

    SITOP PSU100S 24 V/10 A stabilized power supply input: AC 120/230 V output: DC 24 V/10 A.

    General information:

    Entrance:

    Form of the electrical network Single-phase AC
    supply voltage at AC
    ● initial value Automatic range switching
    supply voltage
    ● 1 at AC rated value 120 V
    ● 2 with AC 230 V rated value
    input voltage
    ● 1 with AC 85 ... 132 V
    ● 2 with AC 170 ... 264 V
    input design wide input range No
    overloadability due to overvoltage 2.3 x Ue nom, 1.3 ms
    backup operating condition due to lack of
    mains voltage With Ue = 93/187 V
    backup time with rated value of the
    output current in case of mains voltage failure min. 20 ms
    backup operating condition due to lack of mains voltage             
    With Ue = 93/187 V
    mains frequency
    ● 1 nominal value 50 Hz
    ● 2 value rated 60 Hz
    mains frequency 47 ... 63 Hz
    input current
    ● at rated input voltage 120 V 4.49 A
    ● at rated input voltage 230 V 1.91 A
    current limitation of the inrush current at 25 °C max. 60 A
    I2t value max. 5.6 A²·s
    execution of protection T 6.3 A/250 V (not accessible)
    ● of the mains cable Recommended circuit breaker: apart. from 10 A characteristic C
    Output
    shape of the voltage curve at the output regulated potential-free DC voltage
    output voltage with DC rated value 24 V output voltage
    ● at output 1 with DC nominal value 24 V
    relative overall voltage tolerance 3 %
    relative control accuracy of the output voltage
    ● with slow fluctuation of the input voltage 0.1 %
    ● with slow ohmic load fluctuation 1 %
    residual ripple
    ● max. 150 mV
    ● typ. 20 mV
    peak voltage
    ● max. 240 mV
    ● typ. 160 mV
    output voltage adjustable 22.8 ... 28 V
    product function output voltage adjustable Yes
    type of setting of the output voltage Via potentiometer
    display execution for normal operation LED green for 24 V O.K.
    type of signal at the output Relay contact (open contact, loadability DC 60 V/0.3 A) for "24 V O.K."
    progression of the output voltage at switch-on Overshoot of Ua < 3 %
    max. intervention delay 0.3 s
    voltage rise time of the output voltage
    ● typ. 20 ms
    output current
    ● rated value 10 A
    ● rated range 0 ... 12 A; 12 A ... +45 °C; +60 ... +70 °C: Derating 3%/K
    exported active power typ. 288 W
    short-time overload current
    ● in case of short circuit during normal starting typ. 32 A
    ● in the event of a short circuit during typical operation. 32 A
    duration of overloadability due to overcurrent
    ● in case of short circuit during start-up 1 000 ms
    ● in case of short circuit during operation 1 000 ms
    product characteristic● parallel connection of equipment Yes
    number of equipment connected in parallel for power increase
    2
    Efficiency
    efficiency [%] 90 %
    power dissipated [W]
    ● with nominal value of the output voltage with nominal value
    of the output current typ. 25 W
    Regulation
    relative regulation accuracy of the output voltage with
    rapid input voltage fluctuation of +/- 15 % typ.0.3 %
    relative regulation accuracy of the output voltage with
    step variation of the ohmic load 10/90/10 % typ. 3 %

    • Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT IT04742820618

    DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account