SCHNEIDER ELECTRIC SAFETY DETECTION

10 products

  • XPSUAT33A3AP | Schneider Electric

    SCHNEIDER ELECTRIC XPSUAT33A3AP | Schneider Electric

    Schneider Electric XPSUAT33A3AP The product is part of the XPS Universal range of safety relays. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP and NPN sensors, RFID safety switches, safety barriers, and sensitive mats/edges. The safety module is powered by 48-240V AC/DC and equipped with a screw-on terminal. It can transmit more than 40 different status messages from the output of the module to a standard digital input of a PLC, reducing downtime and indicating the cause of the production stoppage. The safety relay includes 2 positive and 1 negative safety inputs, 4 configurable pulse outputs ON/OFF, 3 immediate NO safety outputs, 3 configurable NOs, 1 configurable NC and 2 diagnostic outputs.  The maximum level of safety achieved by this safety module is PLe/Category 4 according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508. The safety module has a weight of 0.350 kg. Dimensions: 45 mm (width) x 120 mm (depth) x 100 mm (height).  These safety modules are suitable for applications in food, lifting, material handling, material processing, packaging and are designed for a wide range of industrial machines. The safety module complies with IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061, IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061, and is cULus and TUV certified. The module is mounted on a symmetrical 35 mm DIN rail. Preventa XPS Universal safety relays are the first choice for easily managing safety functions, typically for simple to medium complexity machines.

    €317,40

  • XPSMCMRO0004 | Schneider Electric

    SCHNEIDER ELECTRIC XPSMCMRO0004 | Schneider Electric

    Schneider Electric XPSMCMRO0004The Schneider Electric XPSMCM Safety Relay Output Expansion Module has 4 start/restart interlock inputs, 4 relays, and captive screw terminals. This safety controller relay output expansion module meets the requirements of PL e/Category 4 according to EN/ISO 13849-1 and SILCL3 according to EN/IEC 62061. It offers line control monitoring via dedicated test outputs, configurable filters and delays for each individual input, configurable output activation and deactivation, independent control of pairs of outputs, configurable diagnostic output signals and simple diagnostics via front signaling, configuration software, communication expansion modules.

    €347,55

  • XPSUS12AP | Schneider Electric

    SCHNEIDER ELECTRIC XPSUS12AP | Schneider Electric

    Schneider Electric XPSUS12APThe product is part of the XPS Universal range of security modules. It is designed for monitoring emergency stops, safety, magnetic, proximity or RFID safety switches, PNP sensors, safety barriers, two-hand control stations or hold-open control switches. The safety module is powered by 24V AC/DC and equipped with an extractable screw terminal. It can transmit more than 40 different status messages from the module output to a standard digital input of a PLC, reducing machine downtime and indicating the cause of the production stoppage. The safety module includes 2 safety inputs, 3 configurable ON/OFF pulse outputs, 2 NO safety outputs and 1 diagnostic output with complete status information. The maximum safety level achieved by this safety module is PLe/Category 4 compliant with ISO 13849-1, SILCL 3 compliant with IEC 62061, SIL 3 compliant with IEC 61508. The safety module has a weight of 0.200 kg. Dimensions: 22.5mm (width) x 120mm (depth) x 100mm (height). These safety modules are suitable for applications in food, lifting, material handling, materials processing, packaging and are designed for a wide range of industrial machines. The safety module complies with the standards IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061, IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061 and is cULus and TUV certified. The module is mounted on a 35mm symmetrical DIN rail. Preventa XPS Universal safety modules are the first choice for easily managing safety functions, generally for machines of simple to medium complexity.

    €189,20

  • XPSUAT13A3AP | Schneider Electric

    SCHNEIDER ELECTRIC XPSUAT13A3AP | Schneider Electric

    Schneider Electric XPSUAT13A3APCat.4 safety module character. XPSUAK + timing outputs yes. 24V m.screw

    €303,60

  • XPSUAF13AC | Schneider Electric

    SCHNEIDER ELECTRIC XPSUAF13AC | Schneider Electric

    Schneider Electric XPSUAF13ACThe product is part of the XPS Universal range of security modules. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP sensors, RFID safety switches and safety barriers. The safety relay is powered by 24V AC/DC and equipped with a removable spring terminal. It can transmit more than 40 different status messages from the module output to a standard digital input of a PLC, reducing machine downtime and indicating the cause of the production stoppage. The safety module includes 2 safety inputs, 3 configurable ON/OFF pulse outputs, 3 NO safety outputs and 1 diagnostic output with complete status information. The maximum safety level achieved by this safety module is PLe/Category 4 compliant with ISO 13849-1, SILC L 3 compliant with IEC 62061 and SIL 3 compliant with IEC 61508. The safety module has a weight of 0.200 kg. Dimensions: 22.5mm (width) x 120mm (depth) x 100mm (height). These safety modules are suitable for applications in food, lifting, material handling, materials processing, packaging and are designed for a wide range of industrial machines. The safety module complies with the standards IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061, IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061 and is cULus and TUV certified. The module is mounted on a 35mm symmetrical DIN rail. Preventa XPS Universal safety modules are the first choice for easily managing safety functions, generally for simple to medium complexity machines.

    €143,45

  • XPSBAC14AP | Schneider Electric

    SCHNEIDER ELECTRIC XPSBAC14AP | Schneider Electric

    Schneider Electric XPSBAC14APThe XPSAC safety module Schneider Electric controls the emergency stop buttons and limit switches. 24 VAC/DC power supply, has 3 safety circuits, 1 solid state output and captive screw terminal blocks. This safety module meets the requirements of Performance Level PL e/Category 4 according to EN/ISO 13849-1 and SILCL3, in compliance with EN/IEC 61508 and EN/IEC 62061. It can be used to monitor the shutdown circuits of emergency compliant with EN/ISO13850 and EN/IEC 60204-1 standards.

    €132,50

  • XPSUAK12AP | Schneider-Electric safety module UAK 24V M.SCREW

    SCHNEIDER ELECTRIC XPSUAK12AP | Schneider-Electric safety module UAK 24V M.SCREW

    Schneider-Electric safety module UAK 24V M.SCREW XPSUAK12AP The product is part of the XPS Universal security module range. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP and NPN sensors, RFID safety switches, safety barriers and sensitive mats/edges. PresentationProduct rangeHarmony Safety AutomationProduct typeSafety modulesafety module name XPSUAKsafety module applicationMonitored antivalent contactsFor emergency, protection and barrier monitoring4-wire pressure sensor monitoringModule function Emergency stop button with 2 NC contactsSafety monitoring with 1 or 2 limit switchesControl of 2 PNP sensorsMagnetic switch monitoringSafety barrier control RFID safety switch controlSafety barrier monitoring (ESPE)Safety mat controlProximity sensor monitoringMonitoring 1 PNP + 1 NPN sensor Safety levelCan reach PL e/category 4 for NO relay contact conforming to ISO 13849-1Can reach SILCL 3 for NO relay contact conforming to IEC 62061Can reach SIL 3 for NO relay contact conforming to IEC 61508Can reach PL c/category 1 for NC relay contact conforming to ISO 13849-1Can reach SILCL 1 for NC relay contact conforming to IEC 62061Can ' achieve SIL1 for NC relay contact conforming to IEC 61508Reliability data safetyMTTFd > 30 years conforming to ISO 13849-1Dcavg >= 99 % conforming to ISO 13849-1PFHd = 1.13E-09 conforming to ISO 13849-1HFT = 1 conforming to IEC 62061PFHd = 1.13E-09 conforming to IEC 62061SFF > 99% conforming to IEC 62061HFT = 1 conforming to IEC 61508-1PFHd = 1.13E-09 conforming to IEC 61508-1SFF > 99% conforming to IEC 61508-1Type = B conforming to IEC 61508-1topology of the networkNC doublePNP doubleAntivalent double OSSD doubleconnections - terminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexibleTerminal block removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible double conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with maskRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with maskVoltage nominal power supply [Us]24 V AC - 15...10 %24 V DC - 20...20 %Technical characteristicssynchronization time between inputs 0.5 s 2 s 4 sType of startingAutomatic/manual/monitoredPower absorbed in W2.0 W 24 V DCPower consumption in VA5.0 VA 24 V AC 50/60 Hztype of input protectionInternal, electronicsafety outputs2 NO + 1 NCsafety inputs2 safety input 24 V DC 5 mAmaximum wire resistance 500 OhmInput compatibilityNormally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850Double antivalent conforming to ISO 14119Double OSSD conforming to IEC 61496-1-23-wire PNP proximity sensorsRated operational current [Ie]5 A AC-1 for NO relay contact3 A AC-15 for NO relay contact5 A DC-1 for NO relay contact3 A DC-13 for NO relay contact 3 A AC-1 for NC relay contact1 A AC-15 for NC relay contact3 A DC-1 for NC relay contact1 A DC-13 for NC relay contactcontrol outputs 3 configurable on/off pulsed outputinput/output typePulsed semiconductor signaling output. 24 V DC, 20 mA Z1, non-safety relatedConventional thermal current in air [Ith]8 Aassociated fuse rating10 A gG for output circuit NO relay conforming to IEC 60947-1minimum output current10 mA per relay outputminimum output voltage12 V per relay outputRated insulation voltage [Ui]250 V (pollution degree 2) conforming to IEC 60947-1Rated impulse withstand voltage [Uimp]4 kV overvoltage category II conforming to IEC 60947-1Installation35 mm symmetrical DIN raildepth120 mmheight100 mmwidth22.5 mmproduct weight0.200 kg

    €181,30

  • XPSUAB11CP | Schneider-Electric Cat.1 NC/NC safety module

    SCHNEIDER ELECTRIC XPSUAB11CP | Schneider-Electric Cat.1 NC/NC safety module

    Schneider-Electric Safety module Cat.1 NC/NC  XPSUAB11CP Cat.1 safety module NC/NC, NO/NC free from power. and PNP/PNP 24V screw m. The product is part of the XPS Universal range of security modules. The safety relay is designed for monitoring emergency stops, antivalent contacts, safety, magnetic or proximity switches, PNP sensors, RFID safety switches, safety barriers or two-hand controls. Technical dataProduct rangeHarmony Safety AutomationProduct typeSafety modulename safety moduleXPSUABsafety module applicationFor monitoring 2-hand controlFor application with contacts in switchingFor emergency monitoring, protection and barriersMonitored antivalent contactsModule functionEmergency stop monitoring 1 channelMobile protection monitoring 1 channel 1 PNP sensor monitoringType IIIA two-hand control controlMagnetic switch monitoringSafety barrier controlSafety RFID switch controlSafety barrier monitoring (ESPE)Proximity sensor monitoringSecurity levelCan reach PL c/category 1 compliant with ISO 13849-1Can reach SILCL 1 compliant with IEC 62061Can achieve SIL1 compliant with IEC 61508Safety reliability dataMTTFd >= 30 years compliant with ISO 13849-1Dcavg PFHd = 1177E-09 1/h conforming to ISO 13849-1HFT = 0 conforming to IEC 62061PFHd = 1177E-09 1/h conforming to IEC 62061SFF > 60 % conforming to IEC 62061HFT=0 conforming to IEC 61508-1PFHd = 1177E-09 1/h conforming to IEC 61508-1SFF > 60% conforming to IEC 61508-1 Type = B conforming to IEC 61508-1network topologyDouble NCDouble PNPDouble antivalentDouble OSSD connections - terminalsRemovable screw terminal block, 0.2...2.5 mm² solid or flexibleRemovable screw terminal block, 0.25...2.5 mm² flexible with single conductor ferruleRemovable screw terminal block, 0.2...1.5 mm² solid or flexible double conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with maskRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ring nut with cable end, with maskRated supply voltage [Us]24 V AC - 15...10 %24 V DC - 20...20 % synchronization time between inputs0.5 s2.2 sstarting typeAutomatic/manual/monitoredpower absorbed in W1.5 W 24 V DCpower consumption in VA3.5 VA 24 V AC 50/60 Hztype of input protection Internal, electronicsafety outputs1 C/Osafety inputs1 safety input 24 V DC 5 mA maximum wire resistance500 Ohminput compatibilityNormally closed circuit compliant with ISO 14119XC limit switch compliant to ISO 14119Mechanical contact conforming to ISO 14119Normally closed loop conforming to ISO 13850Dual antivalent conforming to ISO 14119Dual OSSD conforming to IEC 61496-1-2Two-controlled hands compliant with EN 574/ISO 13851-III A3-wire PNP proximity sensorsRated operational current [Ie]5 A AC-1 per contact relay NO3 A AC-15 for relay contact NO5 A DC-1 for relay contact NO3 A DC-13 for relay contact NO3 A AC-1 for relay contact NC 1 A AC-15 for NC relay contact2 A DC-1 for NC relay contact1 A DC-13 for NC relay contactControl Outputs 2 configurable on/off pulsed outputinput/output typePulsed semiconductor signaling output. 24V DC, 20mA Z1, non-safety related Conventional thermal current in air [Ith]3 Aassociated fuse rating6 A gG for IEC compliant relay output 60947-1minimum output current10 mA per relay outputminimum output voltage15 V per output relaymaximum input response time20 msRated insulation voltage [Ui]250 V (degree pollution 2) conforming to IEC 60947-1Rated impulse withstand voltage [Uimp]4 kV overvoltage category II conforming to IEC 60947-1local signalingLED (green)Power ON:LED (red)error:LED (yellow)start:LED (yellow)darkness status:LED (yellow)safety input S12:LED (yellow)safety input S13:Installation35 mm symmetrical DIN raildepth120 mmAmbient temperature-25…55 °Cheight 100 mmwidth22.5 mmproduct weight0.200 kg

    €114,10

  • XPSMCMCP0802

    SCHNEIDER ELECTRIC XPSMCMCP0802 | SCHNEIDER ELECTRIC Modular Safety Controller

    SCHNEIDER ELECTRIC XPSMCMCP0802 The Schneider Electric XPSMCM safety controller CPU is powered by 24 VDC, has 8 digital inputs, 2 interlock inputs for start/restart, 2 output OSSD pairs, 4 test outputs and 2 status outputs and stud terminals. This configurable safety controller complies with the requirements of PL e/Category 4 according to EN/ISO 13849-1 and SILCL3 according to EN/IEC 62061. It is an appropriate solution for machines with a limited number of safety functions that require configuration flexibility of a safety controller. It can be used as a standalone or with fourteen expansion modules: the system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines that require monitoring of multiple safety functions. Click for large 360 ​​view of SCHNEIDER ELECTRIC XPSMCMCP0802

    €259,99

  • XPSUAF13AP

    SCHNEIDER ELECTRIC XPSUAF13AP | Schneider Electric UAF 24V Safety Module

    SCHNEIDER ELECTRIC UAF 24V M.SCREW safety moduleXPSUAF13AP The product is part of the XPS Universal security module range. It is designed for monitoring emergency stops, safety, magnetic or proximity switches, PNP sensors, RFID safety switches and safety barriers. The safety module is powered by 24V AC/DC and equipped with an extractable screw terminal. It can transmit more than 40 different status messages from the module output to a standard digital input of a PLC, reducing machine downtime and indicating the cause of the production stoppage. The safety module includes 2 safety inputs, 3 configurable ON/OFF pulse outputs, 3 NO safety outputs and 1 diagnostic output with complete status information. The maximum safety level achieved by this safety module is PLe/Category 4 compliant with ISO 13849-1, SILC L 3 compliant with IEC 62061 and SIL 3 compliant with IEC 61508. The safety module has a weight of 0.200 kg. Dimensions: 22.5mm (width) x 120mm (depth) x 100mm (height). These safety modules are suitable for applications in food, lifting, material handling, materials processing, packaging and are designed for a wide range of industrial machines. The safety module complies with the standards IEC 60947-5-1, IEC 61508-1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061, IEC 60947-5-1, IEC 61508 -1, IEC 61508-2, IEC 61508-3, ISO 13849-1, IEC 62061 and is cULus and TUV certified. The module is mounted on a 35 mm symmetrical DIN rail. Preventa XPS Universal safety modules are the first choice for easily managing safety functions, generally for simple to medium complexity machines. Click for a 360 degree view of XPSUAF13AP Schneider Electric

    €97,99

© 2024 DMS S.R.L. VAT IT04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account