SCHNEIDER ELECTRIC CONTROL RELAY

1 product

  • XPSUVN11AP | Schneider-Electric Safety module. Harmony XPS

    SCHNEIDER ELECTRIC XPSUVN11AP | Schneider-Electric Safety module. Harmony XPS

    Schneider-Electric Security Module, Harmony XPS  XPSUVN11AP Safety module, Harmony XPS, zero speed control with timing, 24V, screw terminals Technical dataProduct Range Harmony Safety AutomationProduct Type Safety moduleName Safety Module star-delta motor supplied by variable speed driveMonitoring 3-phase motor supplied by servo driveControlling enegization to open of guard switch type XCSE, XCSLE, >Can reach PL e/category 3 for NO relay contact conforming to ISO 13849-1Can reach SILCL 3 for NO relay contact conforming to IEC 62061Can reach SIL 3 for NO relay contact conforming to IEC 61508 Reliability Data Safety MTTFd > 30 years compliant with ISO 13849-1Dcavg = 98.9 % compliant with ISO 13849-1PFHd = 2.39E-9 1/ h conforming to ISO 13849-1HFT = 1 conforming to IEC 62061PFHd = 2.39E-9 1/h conforming to IEC 62061SFF > 99% conforming to IEC 62061HFT = 1 conforming to IEC 61508-1PFHd = 2.39E-9 1/h conforming to IEC 61508-1SFF > 99% conforming to IEC 61508-1Type = B conforming to IEC 61508-1Product Certifications TÜVcULusNominal Power Voltage [Us] 24 V AC - 15...10 % 24 V DC - 20...20 %Output Type Relay, 1 NO circuits, potential-freeNumber of Additional Circuits 2 static outputsMaximum Consumption In W 2.0 WMaximum Power Consumption In Va5.5 VAInput Voltage 690 VInput Detection Threshold 50 mV65 mV85 mV110 mV140 mV180 mV230 mV300 mV400 mV500 mVTiming 0.5 s1 s2 s3 s5 s8 s12 s20 s35 s60 s Rated Operating Current [Ie] 5 A AC-1 for NO relay contact3 A AC-15 for NO relay contact5 A DC-1 for NO relay contact3 A DC-13 for NO relay contactConventional Thermal Current In Air [Ith]6 A for NO relay output circuit Associated Fuse Rating 6 A gG for relay output compliant with IEC 60947-1Standards IEC 60947-5-1IEC 61508-1 function standard safety functionIEC 61508-2 standard safety functionIEC 61508-3 standard safety functionIEC 61508-4 standard safety functionIEC 61508-5 standard safety function IEC 61508-6 standard safety functionIEC 61508-7 standard safety functionISO 13849-1 standard safety functionIEC 62061 standard safety functionMinimum Output Current 10 mA for relay outputMinimum Output Voltage 5 V for relay outputNominal Insulation Voltage[Ui] 690 V phase to phase (pollution degree 2) conforming to IEC 60947-1400 V phase to earth (pollution degree 2) conforming to IEC 60947-1Rated Impulse Withstand Voltage [Uimp]4 kV overvoltage category II conforming to IEC 60947-1Local Signaling Green LED with power markings for Power ONRed LED with error markings for errorYellow LED with state markings for statusYellow LED with L12 markings for input line comparisonYellow LED with L32 markings for input line comparisonConnections - Terminals Removable screw terminal block solid or flexible cable: 0.2...2.5 mm²Removable screw terminal block flexible with ring nut cable: 0.25...2.5 mm² conductor singleRemovable screw terminal block solid or flexible cable: 0.2...1.5 mm² double conductorRemovable screw terminal block flexible with ring nut cable: 2 x 0.25...1 mm² withoutcable end, with bezelFlexible removable screw terminal block with cable ring: 2 x 0.5...1.5 mm² withcable end, with bezelInstallation Symmetrical DIN rail 35 mmDepth 120 mmHeight 100 mmWidth 22, 5 mmProduct Weight 0.2 kg

    €448,05

© 2024 DMS S.R.L. VAT IT04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account