POWER DISTRIBUTION
-
ABB 2CSF202001R4250 | Abb F202 AC-25/0.5
Abb 500MA switch. differenti. pure 2CSF202001R4250 Pure RCDs without thermal-magnetic releases are switches that guarantee the protection of people from indirect contact. Technical data: Reference standards:IEC/EN 61008UL 1053Type of residual current:AC typeRated voltage (Ur):230 VRated operating voltage :230 VRated insulation voltage (Ui):500 VImpulse withstand voltage (Uimp):4 kVRated current (In):25 ARated residual current:500 mA Rated conditional short-circuit current (Inc):10 kARated service short-circuit capacity (Ics):1 kAMaximum Surge Current:0.25 kALeakage Current Type:ACFrequency nominal (f):50 … 60 HzPower loss:a Nominal Operating Conditions per Pole 1 WSupply voltage connection:ArbitraryElectrical resistance:10000 cycle (i)Number of poles :2Operating characteristic:Instant Mounting type: DIN-RailOptions Provided:NoneAccessories Available:YesConnection Capability:Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... . 55 °CAmbient temperature:In operation -25...55 °CDegree of protection:IP2XDegree of pollution:2Vibration resistance according to IEC 60068-2-6:0.1 mm or 1 g - 20 cycles at 5…150…5 HzShock resistance according to IEC 60068-2-27:25g 2 shocks 13 ms
€100,30
-
ABB 2CSM204703R1801 | Abb E 92/32 PV
Abb E 92/32 PV 2CSM204703R1801 Designed for the protection and isolation of direct current circuits of photovoltaic systems up to 1000 V dc.Usage category DC-20B. Technical dataReference standards IEC 60947-3UL 4248-19 Rated voltage (Ur): 1000 VRated operating voltage: DC-20B 1000 V DCRated insulation voltage (Ui): 1 kVRated current ( In): 32 APower loss at Nominal Operating Conditions for Pole 3 WNumber of protected poles: 2Number of poles: 2Tightening torque: 2-2.5 N·m Usage category: DC-20BFuse type: gPVLock Type: Padlockable Mounting type: DIN-RailSeal type: Sealing Wire Material of Conductor: CopperOptions Provided: NoRecommended Screwdriver: Pozidriv 2
€7,46
-
ABB 2CDS274001R0105 | Abb S204M-B10
Abb S204M-B10 S 204 M - B10 - 10kA Curve B 10A - 4P - B - 10 A 2CDS274001R0105 System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200. series differential blocks Technical dataReference standards: IEC/EN 60898-1CSA 22.2 No. 235IEC/EN 60947-2UL 1077Tripping characteristic:BRated operating voltage: according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 440 V AC Operating voltage: Maximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DCRated insulation voltage (Ui): according to IEC/ EN 60664-1 440 VImpulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kVDielectric test voltage: 50/60 Hz , 1 min: 2 kVType of input voltage: AC/DCRated current (In) 10 ARated short-circuit capacity: (AC) 10 kA(230 V AC) 10 kA(400 V AC) 10 kA(400 V) 10 kARated extreme short-circuit capacity (Icu): (230 V AC) 25 kA(400 V AC) 15 kA(440 V AC) 15 kA(230 V) 25 kA(400 V) 15 kARated conditional short-circuit current (Inc ): (230 V) 15 kA(400 V) 25 kA Rated service short-circuit capacity (Ics): (230 V AC) 7.5 kAFrequency (f): 50 HzRated frequency (f): 50 / 60 Hz50 ... 60 HzPower loss: 8.4 Wat Nominal Operating Conditions for Polo 2.1 W
€148,78
-
ABB 1SBE121111R0120 | Abb ESB2020N01
Abb Modular Contactors (NO) 20 A - 2 NO - 0 NC - 24 V - DC Control Circuit (ESB20-20N-01) 1SBE121111R0120 Modular Contactors - Automatic Control - 2 N.O. ContactsESB20-20N-01 installation contactors are used to control single loads up to 20 A and can be operated on AC. or DC.These contactors are made for use in domestic applications and industrial environments.The following benefits are expected:Noise-free operation, low power consumption and integrated overvoltage protection. Different combinations of contacts and accessories are available. Technical dataRated operating voltage: Main Circuit 220 V DCMain Circuit 250 V ACRated control circuit voltage (Uc): 24 VFrequency nominal (f): DC Control Circuit50 Hz Control Circuit60 Hz Control Circuit400 Hz Control CircuitDC Main Circuit50 Hz Main CircuitMain Circuit 60 HzRated operating current AC-1 (Ie): (NO) 20 ARated operating current AC-3 (Ie): (230 V) Single phase, NO 9 ARated operating current AC-1 (Pe): (230 V) Single phase, NO 4. kWRated operating current AC-3 (Pe): (230 V) Single phase, NO 1.3 kWRated operating current AC-7a (Ie): (NO) 20 ARated operating current AC-7a (Pe): (230 V) Single phase, NO 4.6 kWRated operating current AC-7b (Ie): (230 V) Single phase, NO 9 ARated operating current AC-7b (Pe): (230 V) Single phase, NO 1.3 kWRecommended screwdriver: Control Circuit Pozidriv 1 Main Circuit Pozidriv 1Impulse withstand voltage (Uimp): 6 kVRated insulation voltage (Ui): 400 V
€53,03
-
SCHNEIDER ELECTRIC A9A26946 | Schneider-Electric Release current launch
Schneider-Electric Release. current throw iMX+OF 110/415Vac 110/130Vcc A9A26946 This Acti9 iMX+OF auxiliary electrical release for is a shunt release device with open/closed auxiliary contact. It is dedicated to Acti9 iC60, iID, iDPN Vigi, iSW-NA. This device includes an OF open/closed contact to indicate the location of the paired device. Presentationrange of productActi9Product typeRelease coil with open/closed contactDevice nameiMX+OFsignal contact composition1 A/CRated current [In]AC-12 3 A at 415 V , AC 50 HzAC-12 6 A at 100 V, AC 50 HzAC-12 6 A at 230 V, AC 50 HzDC-12 1 A at 110 V, DC DC-12 1 A at 130 V, DCControl voltage [Uc]100...415 V AC 50/60 Hz110...130 V DC9 mm pitch 2Technical characteristicsRange compatibilityActi9 -Acti9 Acti9 ARAActi9 -Acti9 Acti9 iIDActi9 Acti9 iSW -NAActi9 Acti9 RCAActi9 Acti9 iDPN (China version)Acti9 Acti9 iC60 two-terminal thermomagnetic switchActi9 Acti9 iC40Local signalingIndicator actionInstallationHookupInstallationDIN raildistribution comb compatibilityTop part: YESwidth18 mm ColorWhiteconnections - terminalsClip terminal - 2 cables 2.5 mm² - flexible with cable terminationClip terminal - 1 cable 6 mm² - rigidClip terminal - 2 cables 2.5 mm² - rigidClip terminal - 1 cable 4 mm² - flexibletightening torque 1 NmCompatibility codeIMX+OFEnvironmentReference standardsCEI EN 60947-5-1tropicalization2 compliant with CEI EN 60947-5-1relative humidity95 % at 55 °CAmbient temperature-25…50 °CStorage temperature-40…85 °C
€57,33
-
SCHNEIDER ELECTRIC A9Q41425 | Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block
Schneider Electric QuickVigi iC60 4P 25A 30mA AC Type Differential Block A9Q41425 Acti9 Vigi iC60 is a modular additional residual current device. It is a 4P, rated current of 25A, operating voltage from 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 30 mA and voltage independent technology. This product protects against short circuits, wire overloads, electric shock from indirect contact and fire hazards. A VisiTrip window is here to indicate a fault trip via a red mechanical indicator on the front. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of people and protection of installations. This product complies with IEC 61009-1 and EN 61009-1. The nominal operating voltage Ue is 400 V AC. The rated insulation voltage Ui is 500 V AC. The rated impulse withstand voltage Uimp is 6 kV. The pollution degree is 3. It can be mounted on DIN rail. Width in 9mm steps is 6. Dimensions are (W) 54mm x (H) 91mm x (D) 73.5mm. The weight is 0.245 kg. The degree of protection is IP20 and IP40 in a cabinet. The operating temperature is between -5°C and +60°C. The storage temperature is between -40°C and +85°C. Technical dataRangeActi9Product typeResidual current add-on devicesDevice nameVigi iC60Number of poles4PRated current [In]25 Adifferential sensitivity30 mAtiming differential protectionInstantEarth leakage protection typeAC typeNetwork type ACMains frequency50/60 HzRated operational voltage [Ue]400 V AC 50/ 60 Hz conforming to EN 61009-1400/415 V AC 50/60 Hz conforming to IEC 61009-1conforming to IEC/EN 61009-2-1Reference standardsIEC 61009-1EN 61009-1pitch 9 mm6device position in the systemStarting point residual current release technology"Voltage independent"Rated insulation voltage [Ui]500 V AC 50/60 Hz compliant with IEC 60947-2Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2Gamma compatibilityActi9 Acti9 iC60 Acti9 Acti9 Reflex iC60Product compatibilitySingle terminalLocal signalingTrip indicatorInstallationHookupInstallationDIN railelectrical connection to the circuit breakerPlug incomb compatibility distributionLower part: YESheight91 mmwidth54 mmdepth73.5 mmproduct weight0.245 kgconnections - terminalsBottom side cage terminal for 1 cable 1… 25 mm² rigid without cable endBottom side cage terminal for 1 cable 1…16 mm² flexible without cable endBottom side cage terminal for 1 cable 1…16 mm² flexible with cable end wire stripping length14 mm for lower part connectiontightening torque2 Nm lower part
€230,68
-
SCHNEIDER ELECTRIC A9P54610 | Schneider-electric iC40N 1P+N C 10A 6000A circuit breaker
Schneider-electric Circuit breaker iC40N 1P+N C 10A 6000A A9P54610 This Acti9 iC40N product is a low voltage circuit breaker (MCB). It is a 1P+N switch with 1 protected pole and 10A rated current In and tripping curve C. The rated short-circuit breaking capacity reaches up to 10kA at 230VAC in compliance with the EN/IEC 60947-2 standard and 6000A at 230VAC in compliance with EN/IEC 60898-1. This product complies with industrial standards EN/IEC 60898-1 and residential standards EN/IEC 60947-2. This circuit breaker combines the functions of circuit protection against short circuits and overload current, control and isolation. Installation and wiring are simplified with clip-on functionality and easy maintenance. Technical dataRangeActi9Product nameActi9 iC40Product typeSwitch modularDevice nameiC40NApplicationDistributionNumber of poles1P + Nnumber of protected poles1neutral positionLeftRated current [In]10 AType of networkCARelease technologyMagnetothermalcurve codeCSwitching capacity10 kA Icu compliant with EN/IEC 60947-2 at 230 V AC 50/60 Hz6000 A Icn compliant with CEI EN 60898-1 at 230 V AC 50/60 Hz Aptitude for sectioningComplies with EN/IEC 60947-2quality marksAENOROVEIMQ RCMTechnical characteristicsMains frequency50/60 HzRated operational voltage [Ue]230 V AC 50/60 Hzmagnetic release limit5...10 x In conforming to CEI EN 60898-18 x In +/- 20 % conforming to EN/IEC 60947-2 Rated service breaking capacity [Ics]6000 A 100 % Icn at 230 V AC 50/60 Hz compliant with CEI EN 60898-17.5 kA 75 % Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2limitation class3 conforming to CEI EN 60898-1Rated insulation voltage [Ui]400 V AC 50/60 Hz conforming to EN/IEC 60947-2Rated impulse withstand voltage [Uimp]4 kV conforming to EN /IEC 60947-2contact position signalingYesType of controlLeverLocal signalingON/OFF indicationSnap indicatorInstallationAttachmentInstallationDIN rail9 mm pitch2height85 mmwidth18 mmdepth74 mm product weight120 gColorWhiteMechanical durability20000 cycleselectrical life20000 cyclesDescription of locking optionsPadlock deviceconnections - terminalsTop part cage terminals or lower1…10 mm² flexibleCage terminals upper or lower part1…16 mm² rigidwire stripping length14 mm for upper or lower part connectionpair tightening pressure2 Nm upper or lower partdifferential protectionSeparate block
€60,69
-
SCHNEIDER ELECTRIC METSEPM5110 | Schneider Electric PM5110 power meter 96x96
Schneider Electric PM5110 power meter 96x96 METSEPM5110 The device is a flush mount energy meter with a 96mm x 96mm backlit LCD display. The meter ensures 0.5S accuracy class according to IEC 62053-22 and 64 samples per cycle. The device measures energy, active and reactive power, voltage, current, frequency, power factor and up to the 15th harmonic. The meter operates on a 50 or 60 Hz mains and accepts supply voltages of 100 to 415 V AC and 125 to 250 V DC. The rated line current for this meter is 1A or 5A input and supports single-phase and neutral, three-phase, or three-phase and neutral configurations. The measurement voltage range between phases is 35 to 690 V AC, 47 to 63 Hz. The measurement range between phase and neutral is 20 to 400VAC, 47 to 63 Hz. The communication protocol consists of by Modbus RTU and ASCII 2 cables with RS485 port. The meter also features a digital pulse output and 33 configurable alarms. Product Dimensions: Width 3.78 inches (96 mm), Depth 2.83 inches (72 mm), Height 3.78 inches (96 mm); weight 13.4 oz (380 g). Technical dataRangePowerLogicProduct namePowerLogic PM5000Device name PM5110Product typeMeasuring instrumentTechnical characteristicspower quality analysisUp to the 15th harmonicApplicationEnergy monitoringtype of measurementCurrentVoltageFrequencyPower factorEnergyActive and reactive powersupply voltage90...450 V AC 45...65 Hz100 ...300 V DCMains frequency50 Hz60 HzRated current [In]1 A 5 Atype of network1P + N3P + N3Ppower absorbed in VA11 VA at 415 Vlocal signaling80 ms 120 V AC typical100 ms 230 V AC typical100 ms 415 V AC typical50 ms 125 V DC typicaldisplay typeMonochrome graphic LCDdisplay resolution128 x 128sampling rate64 samples/ cyclecurrent measurement50…8500 mAanalog input typeVoltage (impedance 5 MOhm)Current (impedance measurement voltage35…760 V AC 45...65 Hz between phase and phase20…440 V AC 45...65 Hz between phase and neutralfrequency measurement range45…65 Hznumber of inputs0measurement precision Active energy +/- 0.5%Reactive energy +/- 2%Active power +/- 0.5%Apparent power +/- 0.5%Frequency +/- 0.05%Power factor +/- 0.5Current +/- 0.5%Voltage +/- 0.5%Apparent energy +/- 0.5 %Reactive power +/- 2%precision classClass 0.5S active energy compliant with IEC 62053-22number of outputs1 digitalcommunication port protocolModbus RTU and ASCII at 9.6 - 19.2 - 38.4 kbaud odd/even or none - 2 wires, 2500 V insulationJBUScommunication port protocolRS485data loggingTime indicationMin/max of instantaneous valuesconnections - terminalsVoltage circuit: screw terminal4Control circuit: screw terminal2 Currenttransformer: screw terminal6I/O circuit: screw terminal6RS485 connection: screw terminal4InstallationBuilt-insupport assemblyStructureReference standardsUL 61010-1CEI EN 50470-3CEI EN 50470-1IEC 62053-22 :2020IEC 60529IEC 62053-24IEC 61557-12:2015IEC 62053-23:2020IEC 62052-11:2020IEC 62052-3 1:2015 Product certificationsCE conforming to IEC 61010-1CULus conforming to UL 61010-1width96 mmdepth72 mmheight96 mmproduct weight380 g
€623,20
-
SCHNEIDER ELECTRIC A9DE3616 | Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC
Schneider-Electric Int.mtd ICV40N 1P+N C 16A 30MA type AC A9DE3616 This Acti9 iCV40 is a modular residual current circuit breaker with overcurrent protection (RCBO). It is a 1P+N switch with 1 protected pole, 16A rated current In and tripping curve C. The protection class against earth leakage is AC type with sensitivity of 30 mA. PresentationRangeActi9Product nameActi9 iCV40Product typeThermal circuit breaker differential (RCBO)Device nameiCV40NApplicationDistributionNumber of poles1P + Nnumber of protected poles 1 neutral position LeftRated current [In] 16 AType of AC networkRelease technologyMagnetothermalcurve code Cdifferential sensitivity30 mADifferential protection timingInstantaneoustype of differential protectionAC typeInterrupting capacity6000 A Icn compliant with CEI EN 61009- 2-1 at 230 V AC 50/60 HzSuitable for isolationComplies with EN/IEC 60947-2quality marksIMQ"EAC" VDETechnical characteristicsComplementaryStarting pointMains frequency50/60 HzRated operational voltage [Ue ]230 V AC 50/60 Hzmagnetic trip limit5...10 x InResidual current trip technology"Independent from the voltage"Rated service breaking capacity [Ics]6000 A 100 % Icn at 230 V AC 50/60 Hz compliant with CEI EN 61009-2-1rated breaking and making capacityIdm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1limiting class3 compliant with CEI EN 61009-2-1Rated insulation voltage [Ui]400 V AC 50/60 HzRated impulse withstand voltage [Uimp] 4 kVcontact position signaling YesType of control LeverLocal signalingFault indicationON/OFF indicationInstallationCouplingInstallationDIN raildistribution comb compatibilityUpper or lower part: toothconnection pitch9 mm between phase and neutralpitch 9 mm 4height 85 mmwidth 36 mmdepth 73 mmproduct weight 210 gColor White
€179,52
-
SCHNEIDER ELECTRIC A9S60232 | Schneider Electric iSW 2P 32A disconnect switch
Schneider Electric iSW 2P 32A disconnect switch A9S60232 This Acti9 iSW is a modular and reliable disconnector. It is a 2P, with a rated current of 32 A and an operating voltage of 415 V AC. The electrical resistance reaches up to 30000 cycles and the mechanical resistance reaches up to 300000 cycles. The operating temperature ranges from -20°C to +50°C. PresentationRangeActi9Product nameActi9 iSWProduct typeSwitch operating-disconnectorDevice nameiSWApplicationControlNumber of poles2PUsage categoryAC- 22ASuspension suitabilityYesTechnical characteristicsRated operational current [Ie]32 A at 415 V AC 50/60 HzRated operational voltage [Ue]415 V AC 50/60 HzRated insulation voltage [Ui]500 V AC 50 /60 Hz compliant with CEI EN 60669-2-4Rated impulse withstand voltage [Uimp]4 kVType of control LeverLocal signalingON/OFF indicationcontact position signalingYesInstallationFixedInstallation DIN railpitch 9 mm2height77 mmwidth18 mmdepth70 mmColorWhiteMechanical life300000 cycleslife electrical30000 cyclesconnections - terminalsCage terminals - 10 mm² - rigidCage terminals - 10 mm² - flexibleCage terminals - 10 mm² - flexible with ring nutwire stripping length9 mmTightening torque1.2 NmEnvironmentReference standards CEI EN 60669-2-4degree of protection IPIP4degree of pollution2tropicalization2relative humidity95% at 55 °C Ambient temperature-20…50 °CStorage temperature-40…70 °C
€33,14
-
SCHNEIDER ELECTRIC A9P52616 | Schneider Electric iC40a 1P+N C 16A 4500A circuit breaker
Schneider Electric Circuit breaker iC40a 1P+N C 16A 4500A A9P52616 This Acti9 iC40 product is a low voltage circuit breaker (MCB). It is a 1P+N switch with 1 protected pole and 16A rated current In and tripping curve C. The rated short-circuit breaking capacity reaches up to 6kA at 230VAC in compliance with the EN/IEC 60947-2 standard and 4500A at 230VAC in compliance with EN/IEC 60898-1. This product complies with industrial standards EN/IEC 60898-1 and residential standards EN/IEC 60947-2. This circuit breaker combines the functions of circuit protection against short circuits and overload current, control and isolation. Installation and wiring are simplified with clip-on functionality and easy maintenance. It has an electrical resistance of up to 20,000 cycles and a mechanical resistance of up to 20,000 cycles. The EU operating voltage is 230 V AC. The rated insulation voltage Ui is 400 V AC. The rated impulse withstand voltage Uimp is 4 kV. The operating frequency is 50 Hz or 60 Hz. It can be mounted on a DIN rail for modular installation. Its width is 2 steps of 9 mm. The pollution degree is 3. The color of the product is white (RAL 9003). Overall dimensions are (H) 18mm x (W) 85mm x (D) 74mm. The weight is 120 g. According to IEC 60529, the degree of protection is IP20 and IP40 in the cabinet. The operating temperature is between -25°C and 70°C. The storage temperature is between -40°C and 85°C. RangeActi9Product nameActi9 iC40Product typeModular switchDevice nameiC40ApplicationDistributionNumber of poles1P + Nnumber of protected poles1neutral positionLeftRated current [In]16 A Type of networkCARelease technologyMagnetothermalcurve codeCInterrupting capacity6 kA Icu compliant with EN/IEC 60947-2 at 230 V AC 50/60 Hz4500 A Icn compliant with CEI EN 60898-1 at 230 V AC 50/60 HzAptitude for sectioningYes compliant with EN/IEC 60947-2quality marksKEMAIMQ Technical dataMains frequency50/60 HzRated operational voltage [Ue]230 V AC 50/60 Hzmagnetic trip limit5...10 x In compliant with CEI EN 60898-18 x In +/- 20 % compliant with EN/IEC 60947-2Rated service breaking capacity [Ics] 4500 A 100 % Icn at 230 V AC 50/60 Hz conforming to CEI EN 60898-14.5 kA 75 % Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2class limitation3 conforming to CEI EN 60898-1Rated insulation voltage [Ui]400 V AC 50/60 Hz conforming to EN/IEC 60947-2 Rated impulse withstand voltage [Uimp]4 kV conforming to EN/IEC 60947-2contact position signalingYes Control typeLeverLocal signalingON/OFF indicationTrip indicatorInstallationCoupling InstallationDIN railpitch 9 mm2height85 mmwidth 18 mmdepth74 mmproduct weight120 gColorWhiteMechanical durability20000 cycleselectrical durability20000 cyclesDescription of locking options Padlock deviceconnections - terminalsCage terminals upper or lower part1…10 mm² flexibleCage terminals upper or lower part1…16 mm² rigidlength wire stripping14 mm for upper or lower part connectiontightening torque2 Nm upper or lower partdifferential protectionSeparate block
€17,40
-
SCHNEIDER ELECTRIC A9S60432 | SCHNEIDER ELECTRIC ISW 4P 32A SWITCH DISCONNECTOR
Schneider Electric iSW 4P 32A disconnect switch A9S60432 This Acti9 iSW is a modular and reliable disconnector. It is a 4P, with a rated current of 32 A and an operating voltage of 415 V AC. The electrical resistance reaches up to 30000 cycles and the mechanical resistance reaches up to 300000 cycles. The operating temperature ranges from -20°C to +50°C. The storage temperature ranges from -40°C to +70°C. The degree of protection is IP20 and IP40 in one enclosure. It can be installed on a DIN rail. Width in 9mm steps is 4. Overall dimensions are (H)36mm x (W)77mm x (D)70mm. This disconnector is used for control. This product complies with EN/IEC 60669-2-4. Product Type: Switch disconnectorDevice Name: iSWApplication: ControlNumber of Poles: 4PUsage Category: AC-22AAbility to Disconnect: YesRated Operating Current: [Ie] 32 A at 415 V AC 50/60 HzRated Operational Voltage [Ue]: 415 V AC 50/60 HzRated Insulation Voltage [Ui]: 500 V AC 50/60 Hz conforming to CEI EN 60669-2-4Rated Impulse Withstand Voltage [Uimp]: 4 kV Control type: LeverLocal signaling: ON/OFF indicationContact position signaling: YesInstallation: Fixed Installation Guide: DINpitch 9 mm4height77 mm width36 mmdepth70 mmColourWhiteMechanical durability300000 cycleselectrical life30000 cyclesconnections - terminalsCage terminals - 1 x 10 mm² - rigidCage terminals cage - 1 x 10 mm² - flexibleCage terminals - 2 x 10 mm² - flexible with ring nutwire stripping length9 mmTightening torque 1.2 Nm
€68,47