English
IT

POWER DISTRIBUTION

228 products

  • 223400244340 | Finder 25 A modular contactor

    FINDER 223400244340 | Finder 25 A modular contactor

    Finder modular contactor 25 A 223400244340 Modular contactor 25 A - 4 contacts, 35mm width and a NO contact opening ≥ 3 mm, double break. Type 22.34 complies with EN 61095: 2009 Technical description: Modular contactor, 25 A, 4 contacts, NO, 25 A, AgSnO2, AC/DC coil, 24 V, operation from 19.2 to 26.4 V (AC)/( DC), rated power 2 VA (AC) / 2.2 W (DC), holding voltage 9.6 V (AC)/(DC), release voltage 2.4 V (AC)/(DC), variant: Manual selector + mechanical indicator + LED, ambient temperature -25 to +50 °C

    €40,60

  • 223200244340 | Finder 25A modular contactor

    FINDER 223200244340 | Finder 25A modular contactor

    Finder modular contactor 25A 223200244340 Modular contactors Number of contacts: 2 NO Contact material: AgSnO2 nominal operating voltage: 250 V. max. load. incandescent lamp: 2000 W. max. load of the fluorescent lamp: 500 VA. type of drive voltage: AC/DC nominal drive voltage: 19.2 to 26.4 V. type of operating voltage: AC nominal operating current: 25 A. additional devices possible: yes Degree of protection: IP 20 Optional: Manual selector + mechanical indicator + LED Accessories: Support for panel fixing; 8-pole comb. Technical data Rated operating voltage: 440...440 VRated operating current: 25 ARated control voltage: 24...24 VOperating voltage type: ACControl voltage type: AC / DC Number of NO contacts: 2Number of NC contacts: 0 Max. load incandescent lamps: 2000 WMax. fluorescent lamps: 200 VAWith manual selector: yes Width in number of modules: 1Recess depth: 60.8 mmCan be accessorised: yesProtection degree (IP): IP20

    €29,65

  • 202482300000 | Finder rele ad impulsi

    FINDER 202482300000 | Finder pulse relay 17.5MM 2NO 16A 4 sequential.

    Finder Pulse relay 17.5MM 2NO 16A 4 sequential. 202482300000 Type 20.24 modular pulse relay with bipolar switch, for direct mounting on 35 mm rail (EN 60715). Features: One module width 17.4 mm Test button and mechanical indicator 7 sequences available AC or DC coil Identification card Possibility of connection with illuminated buttons using the adapter 026.00 Cadmium-free contacts

    €24,20

  • 202182300000 | Finder 16 A modular pulse relay

    FINDER 202182300000 | Finder 16 A modular pulse relay

    Finder modular pulse relay 16 A 202182300000 Modular pulse relay, 16A, with 1 NO single-pole switch, for direct mounting on 35mm rail (EN 60715). One module width 17.4 mm, Test button and mechanical indicator, 7 sequences available, AC or DC coil. Technical description: Modular pulse relay, 35 mm rail mounting (EN 60715), 1 NO single pole switch, 16 A, AgNi, AC coil, 230 V, operation from 196 to 253 V, nominal power 6.5 VA, resistance 2500 Ω, absorption 28 mA, ambient temperature from -40 to +40 °C.

    €20,30

  • LV426708 | Schneider-electric Circuit breaker

    SCHNEIDER ELECTRIC LV426708 | Schneider-electric Circuit breaker

    Schneider-electric Compact NSXm Vigi circuit breaker 160A 4P 16kA EverLink connector  LV426708 The LV426708 is a Compact NSXm residual current circuit breaker with Micrologic Vigi 4.1 control unit, 160 A, 16 kA at 415 VAC. It is designed for all standard LV applications. It provides integrated earth leakage protection for transformer-fed distribution systems. It features new features such as Everlink connector technology. It offers plate and DIN rail mounting capabilities and externally visible spring-loaded auxiliaries. This 4-pole integrated residual current circuit breaker (ELCB) is one of the smallest on the market. Dimensions: 108 mm (W) x 144 mm (H) x 80 mm (D). It ensures compliance with international standards (IEC 60947/CCC/EACH) and marine specifications. Technical dataRangeCompactProduct NameCompact NSXmProduct rangeCompact NSXmDevice Name"NSXm 160E"Product typeDifferential circuit breakerApplicationProtectionDistributionNumber of poles4Pprotected poles description"4D"neutral positionLeftRated current [In]160 A at 40 °CRated operational voltage [Ue]440VAC 50/60HzNetwork typeCANetwork frequency50/60 HzAptitude for sectioningYes compliant with EN/IEC 60947-2Category of useCategory A[Icu] rated ultimate short-circuit breaking capacity25 kA Icu compliant with IEC 60947-2 at 220...240 V AC 50/60 Hz16 kA Icu compliant with IEC 60947-2 at 380...415 V AC 50/60 Hz10 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 HzPerformance levelAnd 16 kA 415 V ACRelease Name"Micrologic 4.1"Release technologyElectronictrip unit protection functionsLSoIRControl typeLeverCircuit breaker mounting modeWith screwsHookupRated insulation voltage [Ui]500VAC 50/60HzRated impulse withstand voltage [Uimp]8kV[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA at 380...415 V AC 50/60 Hz compliant with IEC 60947-210 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Mechanical durability20000 cyclesElectrical life10000 cycles at 440V In20000 cycles at 440 V In/2InstallationPlateDIN railConnection terminals1 Everlink connector 2.5…70 mm², flexible copper1 Everlink connector 2.5…95 mm², rigid or stranded aluminum/copperConnection step35mm with diffusers27 mm Without spacers9mm steps12 moduletype of protectionL : for overload protection (thermal)"So": for short-time short-circuit protection with fixed delayI : for Instantaneous short circuit protectionR : for earth leakage protectionRelease gauge160 A at 40 °Cthermal memory20 minutes before and after the shotdifferential protectionIntegratedEarth-leakage protection sensitivity adjustment type IΔnAdjustable[IΔn] earth-leakage protection sensitivity adjustment range0.03…5 ADifferential Sensitivity30 mA for class A100 mA for class A300 mA for class A500 mA for class A1000 mA for class A30 mA for AC class100 mA for AC class300 mA for AC class500 mA for AC class1000 mA for AC class3000 mA for AC class5000 mA for AC classEarth leakage protection delay adjustment type Δt Adjustable[Dt] Erth-loss prefix price delay adjustment interval 0 ms60 ms150 ms500 ms1000 msSecurity SettingsNo protection1 x Ir0.5 x IrNumber of slots for electrical auxiliaries1 slot for OF auxiliary contact1 SD alarm contact slot1 "MN or MX" opening coil slotlocal reportingLED flashing (green) ready for operation:LED 105% Ir (red)Overload:LED 90% Ir (orange)Overload:Length108mmHeight144mmDepth80mmProduct weight1.63 kgColorGrey (RAL 7016)

    €996,30

  • 1489M3D150 | Allen bradley UL489 15 A

    ALLEN-BRADLEY 1489M3D150 | Allen-bradley UL489 15 A miniature circuit breaker

    Allen-bradley UL489 15 A miniature circuit breaker  1489M3D150 Miniature switch, 15 A, 3 pole, 480Y/277Volt AC, type D trip curve, inductive. Technical data Recess depth: 79.38 mm Trip characteristic: D Number of poles (total): 3 Rated current: 15 A Rated voltage: 400 V Voltage type: AC Rated breaking capacity Icu according to IEC 60947-2 at 230 V: 15 kA Rated breaking capacity Icu according to IEC 60947-2 at 400 V: 15 kA Frequency: 50...60 Hz With neutral: no Overvoltage category: 3 Pollution degree: 3 Can be accessorised: yes Protection degree (IP): IP20

    €67,75

  • 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    ABB 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    Abb XT3N 250 TMD 250-2500 4p F F InN=50% 1SDA068066R1 Tmax XT3N 250 fixed four-pole circuit breaker with front terminals and thermomagnetic releases TMD R 250-2500 A neutral = 50% phases. Technical data  Type of switch to associate: Power Distribution Cable sections-main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour8000 cycle (i) Mechanical durability: 240 cycles per hour25000 cycle (i) Number of poles: 4 Opening duration: CB with SOR 15 msCB with UVR 15 ms Multiple order: 1 piece(s) Loss of power: a Nominal Operating Conditions for Polo 17.8 W Product main type: SACE Tmax XT Product name: Moulded-case switch Product type: Automatic Circuit Breaker Rated current (In): 250 A Nominal frequency (f): 50 / 60 Hz Rated voltage (Ur): 690 V Impulse withstand voltage (Uimp): 8 kV Rated instantaneous short-circuit current setting (Ii): 2500 A Rated insulation voltage (Ui): 800V Rated operating voltage: 690 V AC500 V DC  

    €952,90

  • 1SAE231111R0131 | Abb ESB25-31N-01

    ABB 1SAE231111R0131 | Abb ESB25-31N-01

    Abb ESB25-31N-01 1SAE231111R0131 Modular contactors - Automatic control - 3 n.o. contacts + 1 n.c. contact Technical data Rated operating voltage: Main Circuit 220 V DCMain Circuit 400 V AC Nominal control circuit voltage (Uc): 24V Nominal frequency (f): Control Circuit 400 HzControl Circuit 50 HzControl Circuit 60 HzDC Control CircuitMain Circuit 50 HzMain Circuit 60 HzMain Circuit DC Rated operating current AC-1 (Ie): (NC) 25 A(NO) 25 A Rated operating current AC-3 (Ie): (230 V) Single Phase, NC 6 A(230 V) Single Phase, NO 9 A(400 V) Three Phase, NO 9 A Rated operating current AC-1 (Pe): (230 V) Single Phase, NC 5.8 kW(230 V) Single Phase, NO 5.8 kW(400 V) Three Phase, NO 17.3 kW Rated operating current AC-3 (Pe): (230 V) Single Phase, NC 1.3 kW(230 V) Single Phase, NO 1.3 kW(400 V) Three Phase, NO 4 kW Rated operating current AC-7a (Ie): (NC) 25 A(NO) 25 A Rated operating current AC-7a (Pe): (230 V) Single Phase, NC 5.8 kW(230 V) Single Phase, NO 5.8 kW(400 V) Three Phase, NO 17.3 kW Rated operating current AC-7b (Ie): (230 V) Single Phase, NC 6 A(230 V) Single Phase, NO 9 A(400 V) Three Phase, NO 9 A Rated operating current AC-7b (Pe): (230 V) Single Phase, NC 0.9 kW(230 V) Single Phase, NO 1.3 kW(400 V) Three Phase, NO 4 kW Recommended screwdriver: Control Circuit Pozidriv 1Main Circuit Pozidriv 1 Impulse withstand voltage (Uimp): 6 kV Rated insulation voltage (Ui): 500V Cable sections - main circuit: Flexible with Ferrule 1x 1.5 ... 10 mm²Flexible with Ferrule 2x 1.5 ... 2.5 mm²Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²Flexible with Insulated Ferrule 2x 1.5 mm² Flexible 1x 1.5 ... 10 mm²Flexible 2x 1.5 ... 4 mm²Rigid 1x 1.5 ... 10 mm²Rigid 2x 1.5 ... 4 mm² Control circuit-cable sections: Flexible with Ferrule 1x 1 ... 2.5 mm²Flexible with Ferrule 2x 0.75 ... 1 mm²Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 . .. 1 mm²Flexible 1x 1 ... 4.0 mm²Flexible 2x 1 ... 2.5 mm²Rigid 1x 1 ... 4 mm²Rigid 2x 1 ... 2.5 mm² Tightening torque: Control Circuit 0.9 N mMain Circuit 1 N m Cable stripping length: Control Circuit 7 mmMain Circuit 10 mm Degree of protection: IP20 Electrical life: AC-1 (NC) 50000 cycle (i)AC-1 (NO) 130000 cycle (i)AC-3 (NC) 340000 cycle (i)AC-3 (NO ) 500000 cycle (i)AC-7a (NC) 50000 cycle (i)AC-7a (NO) 130000 cycle (i)AC-7b (NC) 340000 cycle (i)AC-7b (NO) 500000 cycle (i) Mechanical durability: 1000000 cycle (i) Number of poles: 4 Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of NC main contacts: 1 Number of main NA contacts: 3 Width in number of modular intervals: 2 Pollution degree: 3 Reference standards: IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 61095UL 60947-1UL 60947-4-1 UL/CSA Technical Department Maximum operating voltage UL/CSA: Main Circuit 480 V AC UL/CSA Scope: (220 ... 240 V AC) Single Phase, NC 1 Hp(220 ... 240 V AC) Single Phase, NO 1 Hp(220 ... 240 V AC) Three Phases, NO 3 Hp(440 ... 480 V AC) Single Phase, NC 2 Hp(440 ... 480 V AC) Single Phase, NO 2 Hp(440 ... 480 V AC) Three Phases , NO 5 Hp UL/CSA main circuit cable cross sections: Solid 16-8 AWGStranded 16-8 AWG UL/CSA control circuit cable cross sections: Solid 16-10 AWGStranded 16-10 AWG UL/CSA tightening torque: Control Circuit 8 in lbMain Circuit 9 in lb

    €44,40

  • 2CSM228735R0802 | Abb TM15/12

    ABB 2CSM228735R0802 | Abb TM15/12

    Abb TM15/12 2CSM228735R0802 Failure-proof doorbell transformers. Voltage: primary 230 V AC - secondary 4-8-12 V a.c. SELV or 12-24 V AC SELV. Technical data Reference standards: IEC/EN 61558-2-8 Application: Residential Primary voltage: 230V Secondary voltage: (6-7) 4 V AC(5-6) 8 V AC(5-7) 12 V AC Secondary current: 1.25 A Maximum output current (Iout): 3.75 A Nominal frequency (f): 50/60 Hz Loss of power: 2.5 W Power: 15 V·A Rated output power: 15 W Insulation class: B Tightening torque: 0.5 N·m

    €18,45

  • 2CDS200912R0001 | Abb S2C-H6R

    ABB 2CDS200912R0001 | Abb S2C-H6R

    Abb S2C-H6R 2CDS200912R0001 Order Code: A563826 - Auxiliary contact. allows the indication of the position of the device contacts. Suitable for MCB S 200 series, SN 201 series (via the SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical data Reference standards: CSA Class 3215-30CSA Class 3215-90GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function: Auxiliary contact Suitable for: S200S200MS200PS200SS300PSN201L+SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Suitable for product class: Miniature Circuit BreakerResidual Current Device Loss of power: 0.5 WMaximum 0.5 W Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of auxiliary contacts c/o (SPDT): 1 Accessory type: Auxiliary contact Mounting position: right Technical information: AUXILIARYCONTACT

    €20,60

  • 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    ABB 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    Abb DDA204 AC-63/0.3 2CSB204001R3630 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type AC Rated voltage (Ur): 230/400 V Rated operating voltage: 230/400 V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 300 mA Leakage Current Type: AC Nominal frequency (f): 50 … 60 Hz Loss of power: 7.6 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 4 Operational characteristic: Instant Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²

    €112,95

  • 1sda066325r1 - ABB

    ABB 1SDA066325R1 | ABB SOR-C XT1..XT4 F/P. Wired opening release

    Abb SOR-C XT1..XT4 F/P 1SDA066325R1 WIRED OPENING RELEASE 220-240V AC-220-250V DC FOR FIXED-REMOVABLE XT1..XT4 Additional information Configuration type: Loose or Configurable Current type: AC/DC Multiple order: 1 piece(s) Product main type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Rated voltage (Ur): 220 ... 240 V AC220 ... 250 V DC Reference standards: IECUL Suitable for: XT1, XT2, XT3, XT4 Suitable for product class: SACE Tmax XT

    €90,30

© 2025 DMS S.R.L. VAT IT04742820618

DMSTECHMART is not a distributor or representative of the brands featured on this site. All product names, logos and trademarks are the property of their respective owners. All company, product and service names used on this site are for identification purposes only.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account