INDUSTRIAL AUTOMATION
-
SIEMENS 3RW30461 BB14 |
Siemens Siemens 3RW3046 1BB14 SIRIUS S3 soft starter 80 A, 45 kW/400 V, 40 °C AC 200-480 V, AC/DC 110-230 V screw terminals Technical data Product brand SIRIUS Product name Softstarter Product scope of delivery ● Integrated bypass contact system Yes ● thyristors Yes Product function ● intrinsic protection of the appliance No ● Motor overload protection No ● thermistor motor protection analysis No ● external reset No ● Adjustable current limitation No ● circuit inside the motor triangle No integral part of the product output for engine brake No insulation voltage rated value V 600 Pollution degree 3, according to IEC 60947-4-2 Thyristor cut-off voltage max. V 1 600 reference code according to EN 61346-2 Q reference code according to DIN 40719 with extension according to IEC 204-2 according to IEC 750 G
€1.037,50
-
ABB 1SFL427001R1311 | Abb
Abb 1SFL427001R1311 Contactors over 100A - AF09…AF2650 three-pole contactors with AC and DC coil - 55 kW (AC-3 400 V). Technical data Number of main contacts NA: 3 Number of main NC contacts: 0 Number of auxiliary contacts NO: 1 Number of NC auxiliary contacts: 1 Rated operating voltage: Main Circuit 690 V Nominal frequency (f): Main Circuit 50 / 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 160 A Rated operating current AC-1 (Ie): (690V) 40°C 160A (690V) 60°C 145A (690V) 70°C 130A Rated operating current AC-3 (Ie): (415V) 55°C 116A (440V) 55°C 116A (500V) 55°C 110A (690V) 55°C 65A (380 / 400 V) 55 °C 116 A (220 / 230 / 240 V) 55 °C 116 A Rated operating current AC-3e (Ie): (415V) 60°C 116A (440V) 60°C 116A (500V) 60°C 110A (690V) 60°C 65A (380 / 400 V) 60 °C 116 A (220 / 230 / 240 V) 60 °C 116 A Rated operating current AC-3 (Pe): (415V) 55kW (440V) 75kW (500V) 75kW (690V) 55kW (380 / 400 V) 55 kW (220 / 230 / 240V) 30kW Rated operating current AC-3e (Pe): (415V) 55kW (440V) 75kW (500V) 75kW (690V) 55kW (380 / 400 V) 55 kW (220 / 230 / 240V) 30kW
€247,65
-
ABB 1SFL487102R1311 | Abb
Abb 1SFL487102R1311 Contactors over 100A - Four-pole contactors AF09...AF370 and EK550..EK1000-275 A (AC-1 690 V) Technical data Number of main contacts NA: 4 Number of main NC contacts: 0 Number of auxiliary contacts NO: 1 Number of NC auxiliary contacts: 1 Rated operating voltage: Main Circuit 1000V Nominal frequency (f): Main Circuit 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 275 A Rated operating current AC-1 (Ie): (1000V) 40°C 250A (1000V) 55°C 225A (1000V) 60°C 225A (1000V) 70°C 185A (690V) 40°C 275A (690V) 55°C 250A (690V) 60°C 250A (690V) 70°C 200A Rated operating current AC-3 (Ie): (415V) 55°C 190A (440V) 55°C 190A (380 / 400 V) 55 °C 190 A (220 / 230 / 240 V) 55 °C 190 A Rated operating current AC-3 (Pe): (415V) 90kW (440V) 110kW (380 / 400 V) 90 kW (220 / 230 / 240V) 55kW
€410,80
-
ABB 1SVR427031R0000 | Abb
Abb 1SVR427031R0000 Switching power supplies, Single phase CP-E series, CP-C.1, CP-E24/1.25 Input 85-264V AC / 90-375V DC, output 24..28V DC 1.25A, Command, control, electronics and safety systems products Technical data Function: Switching power supplies Number of phases: 1 Nominal Input Voltage (UIN): 100 ... 240 V AC Input voltage (Uin): 85 ... 264 V AC 90 ... 375 V DC Nominal frequency (f): 50 Hz Nominal frequency: 47 ... 63 Hz Output Characteristics: U/I Characteristic Curve Rated Output Power: 30W Output power: 30W Rated Output Voltage: 24V DC Output voltage (Uout): 24V DC Rated Output Current: 1.25 A Output current: 1.25 A
€74,05
-
SIEMENS 6SL32430BB301FA0 |
Siemens Siemens 6SL32430BB301FA0 SINAMICS G120 Control Unit CU230P-2 PN PROFINET integrated 6 DI, 3 DO, 4 AI, 2 AO 1 motor temperature sensor input sensor input 2 PSU outputs (DC 10V, DC 24V) 1 PSU-in (DC 24V) USB and MMC interface Degree of protection IP20 Technical data Number of input phases Others Number of analog outputs 2 Number of analog inputs 2 Number of digital outputs 3 Number of digital inputs 6 Suitable for use in the industrial sector No Suitable for use in the commercial/domestic sector No Supports TCP/IP protocol Yes Supports PROFIBUS protocol No Supports CAN protocol No Supports INTERBUS protocol No Supports ASI protocol No Supports EIB/KNX protocolno Supports MODBUS protocol No Supports Data-Highway protocol No Supports DeviceNet protocol No Supports SUCONET protocol No Supports LON protocol No Supports PROFINET IO protocol No Supports PROFINET CBA protocol No Supports SERCOS protocol No Supports Foundation Fieldbus protocol No Supports Ethernet/IP protocol Yes Supports AS-Interface Safety at work protocol No Supports DeviceNet Safety protocol No Supports INTERBUS-Safety protocol No Supports PROFIsafe protocol Yes Supports SafetyBUS p protocol No
€383,70
-
ABB 1SBL281024R8010 | Abb
Abb 1SBL281024R8010 Contactors up to 100A - UA contactors for capacitor switching - 30 kvar (400 V 40°C), with pre-discharge resistors Technical data Number of main contacts NA: 3 Number of main NC contacts: 0 Number of auxiliary contacts NO: 1 Number of NC auxiliary contacts: 0 Reference standards: IEC/EN 60947-1, IEC/EN 60947-4-1 Rated operating voltage: Auxiliary Circuit 690 V Main Circuit 690 V Nominal frequency (f): Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-5-1, q = 40 °C 16 A Rated operating current AC-6b (Pe): (230 / 240 V) 40 °C, 50 / 60 Hz 16 kvar (230 / 240 V) 55 °C, 50 / 60 Hz 16 kvar (230 / 240 V) 70 °C, 50 / 60 Hz 11 kvar (400 / 415 V) 40 °C, 50 / 60 Hz 30 kvar (400 / 415 V) 70 °C, 50 / 60 Hz 19.5 kvar (400 / 415 V) 55 °C, 50 / 60 Hz 27.5 kvar (440 V) 40 °C, 50 / 60 Hz 32 kvar (440 V) 55 °C, 50 / 60 Hz 30 kvar (440 V) 70 °C, 50 / 60 Hz 20.5 kvar (500 / 550 V), 40 °C, 50 / 60 Hz 34 kvar Show more Rated operating current AC-15 (Ie): (500V) 2A (690V) 2A (24 / 127V) 6A (220 / 240V) 4A (380 / 400V) 3A
€107,30
-
ABB 1SBH137001R1440 | Abb
Abb 1SBH137001R1440 Contactors up to 100A - NF auxiliary contactors with standard AC and DC coil - 4 contacts with 4 A rating (AC-15/230 V), contacts on one plane. Technical data Number of auxiliary contacts NO: 4 Number of NC auxiliary contacts: 0 Reference standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13 Rated operating voltage: Auxiliary Circuit 690 V Nominal frequency (f): Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-5-1, q = 40 °C 16 A Rated operating current AC-15 (Ie): (500V) 2A (690V) 2A (24 / 127V) 6A (220 / 240V) 4A (400 / 440V) 3A Rated short-time withstand current (Icw): for 0.1 s 140 A for 1 s 100 A Maximum electrical switching frequency: AC-15 1200 cycles per hour DC-13 900 cycles per hour Rated operating current DC-13 (Ie): (24V) 6A / 144W (48V) 2.8A / 134W (72V) 1A / 72W (110V) 0.55A / 60W (125V) 0.55A / 69W (220V) 0.27A / 60W (250V) 0.27A / 68W (400V) 0.15A / 60W (500V) 0.13A / 65W (600V) 0.1A / 60W
€21,80
-
ABB 1SAM350010R1007 | Abb
Abb 1SAM350010R1007 MS132-2.5K MOTOR PROTECTION Technical data Rated service short circuit capacity (Ics): (230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400VAC) 100kA (440VAC) 100kA (500VAC) 100kA (690VAC) 100kA Rated extreme short circuit power (Icu): (230 V AC) 100 kA (400VAC) 100kA (440VAC) 100kA (500VAC) 100kA (690VAC) 100kA Instantaneous short-circuit rated current setting (Ii): 31.3 A Setting field: 1.6 ... 2.5 A Rated operating current AC-3 (Pe): (400 V) Three Phase 0.75 kW Rated operating current AC-3e (Pe): (400 V) Three Phase 0.75 kW Rated operating voltage: Main Circuit 690 V AC Main Circuit 250 V DC Rated operating current (Ie): 2.5 A Rated operating current AC-3 (Ie): 2.5 A Rated operating current AC-3e (Ie): 2.5 A Rated operating current DC-5 (Ie): 2.5 A
€74,65
-
SIEMENS 3SU11520AB201CA0 |
Siemens 3SU11520AB201CA0 |Siemens Illuminated push button, 22 mm, round, metal, shiny, red, button, flat, momentary, with holder, 1 NC, LED module with integrated LED AC/DC 24V, screw terminal. Main features Number of control elements - 1 Button shape - Flat Button color - Red Hole diameter - 22.3 mm Housing hole width - 29.5 mm
€19,40
-
ABB 2CKA006136A0212 |
ABB 2CKA006136A0212 |ABB 6136 07 UP SMARTTOUCH FLUSH-MOUNTING BOX FOR BUS SYSTEMS Type of accessory / spare part - Assembly box Technical data Product range: KNX Product Type: Mounting housing Design Material: Thermoplastic Color: black Dimensions Product Width: 235mm Product height: 152mm Product Depth: 60mm Net weight of product: 501.5 g Screen Size: 10 in
€85,15
-
Mitsubishi Electric FX2NC-16EX-T-DS | Mitsubishi Electric
FX2NC-16EX-T-DS | Mitsubishi Electric PLC, FX2NC Modular extension unit; 16 inputs. Product dimensions and weight Width (mm) 20.2 Height (mm) 90 Depth (mm) 89 Weight (kg) 0.131
€240,00
-
SIEMENS 5SV43160 |
Siemens 5SV43160 |Siemens Residual current circuit breaker, 2-pole, type AC, In: 63 A, 30 mA, Un AC: 230 V The use of these devices is not permitted in all countries. Observe the national installation regulations. Classifications Version Classification eClass 1200 27-14-22-01 eClass 1400 27-14-22-01 eClass 600 27-14-22-01 eClass 710 27-14-22-01 eClass 800 27-14-22-01 eClass 900 27-14-22-01 eClass 910 27-14-22-01 ETIM 700 EC000003 ETIM 800 EC000003 ETIM 900 EC000003 UNSPSC 1500 39-12-16-01
€131,90
-
SCHNEIDER ELECTRIC TM5SAI2L |
Schneider Electric Schneider Electric TM5SAI2L Analog input module 2 inputs, +/-10 V / 0...20mA / 4...20mA, 12 bits. Product range: Modicon TM5 - Product or component type: Analog input module - Analog input type: Current 0...20 mA/4...20 mA, differential, Voltage +/- 10 V, differential - Analog input resolution: 12 bits + sign +/- 10 V, 12 bits 0...20 mA/4...20 mA. Technical data Range compatibility Modicon M258 Modicon LMC058 Product Compatibility Logic controller Motion controller resolution measure 2.441mV, +/- 10V 4.883 µA, 0...20 mA/4...20 mA Color White input impedance >= 20 mOhm voltage ohmic load impedance <= 300 Ohm (current) sampling duration 1 ms, analog input type: all inputs with filtering 300 µs, analog input type: all inputs without filtering measurement error < 0.08% of full scale +/- 10 V +/- 10 V at 25 °C < 0.08% of full scale 0...20 mA/4...20 mA at 25 °C temperature coefficient +/- 0.009 %FS/°C, analog input type: current +/- 0.006 %FS/°C, analog input type: voltage non-linearity < 0.025%FS, analog input type: voltage < 0.05%FS, analog input type: current Type of cables Shielded cable insulation No insulation between channels 500 Vrms AC isolation between channel and bus Diet Internal Rated supply voltage [Us] 24V DC -15...20% Common mode rejection > 70dB local reporting 1 green LED for power 1 red LED for power 2 green LEDs for input status current absorption 2 mA at 5 V DC bus 33 mA at 24 V DC input/output Maximum power dissipation in W 0.81W Marking THERE IS Net weight 0.025 kg
€295,05
-
ABB
ABB 1SBL177001R1310 Abb AF16-30-10-13 - bob. 100...250 V AC/DC, aux 1NO Contactors up to 100A - AF09…AF2650 three-pole contactors with AC coil and DC-7.5 kW (AC-3 400 V) Technical data Number of main NA contacts: 3 Number of main NC contacts: 0 Number of NO auxiliary contacts: 1 Number of NC auxiliary contacts: 0 Reference standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1 Rated operating voltage: 690 V Auxiliary Circuit Main Circuit 690 V Rated frequency (f): Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 35 A according to IEC 60947-5-1, q = 40 °C 16 A Rated operating current AC-1 (Ie): (690V) 40°C 30A (690V) 60°C 30A (690V) 70°C 26A Rated operating current AC-3 (Ie):(415V) 60°C 18A (440V) 60°C 18A (500V) 60°C 15A (690V) 60°C 10.5A (380 / 400 V) 60 °C 18 A (220 / 230 / 240 V) 60 °C 18 A Rated operating current AC-3e (Ie): (415V) 60°C 18A (440V) 60°C 18A (500V) 60°C 15A (690V) 60°C 10.5A (380 / 400 V) 60 °C 18 A (220 / 230 / 240 V) 60 °C 18 A Rated operating current AC-3 (Pe):(400V) 7.5kW (415V) 9kW (440V) 9kW (500V) 9kW (690V) 9kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Rated operating current AC-3e (Pe): (415V) 9kW (440V) 9kW (500V) 9kW (690V) 9kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Rated operating current AC-15 (Ie): (500V) 2A (690V) 2A (24/127V) 6A (220 / 240V) 4A (400 / 440V) 3A Rated short-time withstand current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 AMaximum breaking capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A Maximum electrical switching frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Rated operating current DC-1 (Ie):(110V) 1-Pole, 40°C 20A (110V) 1-Pole, 60°C 20A (110V) 1-Pole, 70°C 20A (110V) 2 Poles in Series, 40°C 30A (110V) 2 Poles in Series, 60°C 30A (110V) 2 Poles in Series, 70°C 26A (110V) 3 Poles in Series, 40°C 30A (110V) 3 Poles in Series, 60°C 30A (110V) 3 Poles in Series, 70°C 26A (220V) 2 Poles in Series, 40°C 20A Show more Rated operating current DC-3 (Ie): (110V) 1-Pole, 40°C 8A (110V) 1-Pole, 60°C 8A (110V) 1-Pole, 70°C 8A (110V) 2 Poles in Series, 40°C 30A (110V) 2 Poles in Series, 60°C 30A (110V) 2 Poles in Series, 70°C 26A (110V) 3 Poles in Series, 40°C 30A (110V) 3 Poles in Series, 60°C 30A (110V) 3 Poles in Series, 70°C 26A (220V) 2 Poles in Series, 40°C 8A Show more Rated operating current DC-5 (Ie):(110V) 1-Pole, 40°C 4A (110V) 1-Pole, 60°C 4A (110V) 1-Pole, 70°C 4A (110V) 2 Poles in Series, 40°C 20A (110V) 2 Poles in Series, 60°C 20A (110V) 2 Poles in Series, 70°C 20A (110V) 3 Poles in Series, 40°C 30A (110V) 3 Poles in Series, 60°C 30A (110V) 3 Poles in Series, 70°C 26A (220V) 2 Poles in Series, 40°C 4A Show more Rated operating current DC-13 (Ie): (24V) 6A / 144W (48V) 2.8A / 134W (72V) 1A / 72W (110V) 0.55A / 60W (125V) 0.55A / 69W (220V) 0.27A / 60W (250V) 0.27A / 68W (400V) 0.15A / 60W (500V) 0.13A / 65W (600V) 0.1A / 60W Rated insulation voltage (Ui):acc. to IEC 60947-4-1 690 V acc. to IEC 60947-5-1 690 V according to UL/CSA 600 V Impulse withstand voltage (Uimp): 6kV Maximum mechanical switching frequency: 3600 cycles per hour Rated control circuit voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V Operation in DCin CD 100 ... 250 V Maneuvering time: Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 msDIN rail mounting: TH35-15 (35 x 15 mm Mounting Bar) according to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Bar) according to IEC 60715 Mounting with screws (not supplied): 2 x M4 screws placed diagonally Cable sections - main circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm² Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 4 mm² Rigid Stranded 1/2x 1 ... 6 mm² Sections of the cables - auxiliary circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² Cable sections - control circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²Cable stripping length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm Degree of protection: according to IEC 60529, IEC 60947-1, EN 60529 IP20 Main Terminals according to IEC 60529, IEC 60947-1, EN 60529 IP20 coils according to IEC 60529, IEC 60947-1, EN 60529 IP20 Auxiliary TerminalsClamp Type: Screw Terminals UL/CSA technical department Maximum operating voltage UL/CSA: Main Circuit 600 V UL/CSA rated operational power: (600 V AC) 30 A UL/CSA Scope: (120 V AC) Single phase 1-1/2 hp (200 ... 208 V AC) Three Phase 5 hp (220 ... 240 V AC) Three Phase 5 hp (240 V AC) Single phase 3 hp (440 ... 480 V AC) Three Phase 10 hp (550 ... 600 V AC) Three Phase 15 hp UL/CSA main circuit cable cross sections:Rigid Solid 1/2x 16-10 AWG Rigid Stranded 1/2x 16-10 AWG UL/CSA auxiliary circuit cable sections: Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG UL/CSA control circuit cable sections: Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG UL/CSA tightening torque: Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 13 in·lbEnvironmental data Room temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Climate resistance: Category B according to IEC 60947-1 Annex Q Maximum permitted operating altitude: Without Derating 3000 m Impact resistance according to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: At 30 g Shock Direction: B2 15g Shock Direction: C1 25g Shock Direction: C2 25g Vibration resistance according to IEC 60068-2-6: 4g Closed Position & 2g Open position 5 ... 300 Hz
€30,30
-
AMERICAN ELECTRICAL INC 11161250 | American Electrical INC
American Electrical INC 11161250 Insulated lug for 4 AWG wire Technical dataLength: 16 mmDiameter: 29 mmMinimum diameter: 11 mmMaterial: CopperColor: Yellow
€1,30
-
AMPHENOL AEROSPACE M39029/56-351 | Amphenol Aerospace
M39029/56-351 Amphenol Aerospace Female Connector Contact 20-24AWG Size 20 Crimp Gold Technical dataType of contactFemale connectorContact dimensions20Conductor section or gap - AWG20-24AWGSection conductor or gap - mm²-Conductor section or gap - Coaxial-Contact terminationCrimpContact materialCopper alloyContact finishGoldContact finish thickness50.0µin (1.27µm)
€1,15
-
3M 17304-ES | 3M
3M 17304-ES Adhesive hooks for rolled cables Technical dataPackage Contents2 cable hooks, 3 medium strips.DimensionsMediumInternal/ExternalInternal BrandsCommand™Weight capacity (metric)0.9 kgDimensions and classificationsOverall height (metric)94 mmOverall width (metric) metric)26 mm
€7,65
-
APEM 5236CDB | Apem
Apem 5236CDB No On-On SPST Toggle Switch with PC Terminals Technical dataContact configuration SPSTOperations On-OnContact rated current 0.4VAMounting type PCBTerminal type PC Terminal Illuminated NoActuator length 10.5mmActuator material Nickel-plated brassRated voltage 20V AC/DCContact material Gold-plated brassContact resistance 10mΩOperating temperature range -40 → + 85°CMinimum operating temperature -40°CMechanical life 100000OperationsMaximum operating temperature +85°C
€7,30
-
TE CONNECTIVITY T92P7D22-24 | TE Connectivity
TE Connectivity T92P7D22-24 TE Connectivity T92 Series Power Relay, DPST, 24V dc Coil, Flange Mount Technical dataCoil voltage 24V dcContact configuration DPSTMounting type Flange mountingSwitching current 30ANumber of poles 2 Bistable NoTerminal type Quick connectLength 68.58mmCoil resistance 350ΩMaximum operating temperature +85°CMinimum operating temperature -55°CContact material Silver alloy Series T92Height 38mmDepth 34.5mmApplication Power
€25,65
-
AMPHENOL AEROSPACE M39029/56-348 | Amphenol Aerospace
Amphenol Aerospace M39029/56-348 The M39029/56-348 is a crimp contact for use with MIL-DTL-38999 III/II series LJT/SJT and TV/CTV circular connectors, female type with crimp termination. Gold plating over suitable subplating, in accordance with SAE AS39029. Technical dataProduct range: TV/CTVContact type: femaleContact termination type: crimpMax AWG wire dimensions: 22AWGDimensions Min AWG Wire: 28AWGUse With: MIL-DTL-38999 Series II & III ConnectorsContact Coating: Gold Contacts
€0,80
-
MOLEX INCORPORATED 39000038 | Molex Incorporated
Molex Incorporated 39000038 The 39-00-0038 is a 18-24, 22+22AWG Tin (Sn) over Copper (Cu) plated brass Mini-Fit female crimp terminal Technical dataApplications: power, wire-to-board, wire-to-wireMaximum current per contact: 9.0AMaximum rated voltage: 600VLife: 30 mating cycles (maximum)Terminal/attachment plating: 0.889µmWire insulation diameter: 1.30 to 3.10mm
€0,05
-
PHOENIX CONTACT 2961105 | Phoenix Contact
Phoenix Contact 2961105 Miniature plug-in power relay, with power contact, 1 changeover contact, input voltage 24 V DC Technical dataProduct type Single relayOperation 100 % EDMechanical life 2x 107 operating cyclesData maintenance status Last data management date 18.06.2024Article revision 02Insulation characteristicsOvervoltage category IIIPollution degree 3Electrical characteristicsMaximum dissipated power in nominal conditions 0, 17 WTest voltage (Wind/Contact) 4 kV AC (50 Hz, 1 min., winding/contact)
€5,75
-
Netgear GS105NA | Netgear
Netgear GS105NA 5-Port Unmanaged Gigabit Ethernet Switch Technical dataNo. of Ports: 5PortsEthernet Switch Application: -Ethernet Switch Type: Unmanaged Gigabit EthernetEthernet Switch Mounting: Desktop / WallPort Types: RJ45 x 5Network Speed: 10Mbps, 100Mbps, 1GbpsInput Voltage Type: VDCProduct Range: -
€71,45
-
Klein Tools 53751 | Klein Tools
Klein Tools 53751 Flexible Auger Bit 3/4 inch x 72 inch Technical dataBit Diameter:3/4'' (19 mm)Shank Diameter:0.4''Overall Length: 72'' (182.9 cm)For Use With:Flex Bit Extension (Cat. No. 53722); Flex Bit Placement Tool (Cat. No. 53715SEN)Weight:2.0 lb (0.9 kg)UPC:092644537516
€70,00