Rated operating voltage:
690 V Auxiliary Circuit
Main Circuit 690 V
Rated frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional free air thermal current (Ith):
according to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
according to IEC 60947-5-1, q = 40 °C 16 A
Rated operating current AC-1 (Ie):
(690V) 40°C 30A
(690V) 60°C 30A
(690V) 70°C 26A
Rated operating current AC-3 (Ie):(415V) 60°C 18A
(440V) 60°C 18A
(500V) 60°C 15A
(690V) 60°C 10.5A
(380 / 400 V) 60 °C 18 A
(220 / 230 / 240 V) 60 °C 18 A
Rated operating current AC-3e (Ie):
(415V) 60°C 18A
(440V) 60°C 18A
(500V) 60°C 15A
(690V) 60°C 10.5A
(380 / 400 V) 60 °C 18 A
(220 / 230 / 240 V) 60 °C 18 A
Rated operating current AC-3 (Pe):
(400V) 7.5kW
(415V) 9kW
(440V) 9kW
(500V) 9kW
(690V) 9kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated operating current AC-3e (Pe):
(415V) 9kW
(440V) 9kW
(500V) 9kW
(690V) 9kW
(380 / 400 V) 7.5 kW
(220 / 230 / 240 V) 4 kW
Rated operating current AC-15 (Ie):
(500V) 2A
(690V) 2A
(24/127V) 6A
(220 / 240V) 4A
(400 / 440V) 3A
Rated short-time withstand current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Maximum breaking capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum electrical switching frequency:
AC-1 600 cycles per hour
AC-15 1200 cycles per hour
AC-2 / AC-4 300 cycles per hour
AC-3 1200 cycles per hour
DC-13 900 cycles per hour
Rated operating current DC-1 (Ie):
(110V) 1-Pole, 40°C 20A
(110V) 1-Pole, 60°C 20A
(110V) 1-Pole, 70°C 20A
(110V) 2 Poles in Series, 40°C 30A
(110V) 2 Poles in Series, 60°C 30A
(110V) 2 Poles in Series, 70°C 26A
(110V) 3 Poles in Series, 40°C 30A
(110V) 3 Poles in Series, 60°C 30A
(110V) 3 Poles in Series, 70°C 26A
(220V) 2 Poles in Series, 40°C 20A
Show more
Rated operating current DC-3 (Ie):
(110V) 1-Pole, 40°C 8A
(110V) 1-Pole, 60°C 8A
(110V) 1-Pole, 70°C 8A
(110V) 2 Poles in Series, 40°C 30A
(110V) 2 Poles in Series, 60°C 30A
(110V) 2 Poles in Series, 70°C 26A
(110V) 3 Poles in Series, 40°C 30A
(110V) 3 Poles in Series, 60°C 30A
(110V) 3 Poles in Series, 70°C 26A
(220V) 2 Poles in Series, 40°C 8A
Show more
Rated operating current DC-5 (Ie):
(110V) 1-Pole, 40°C 4A
(110V) 1-Pole, 60°C 4A
(110V) 1-Pole, 70°C 4A
(110V) 2 Poles in Series, 40°C 20A
(110V) 2 Poles in Series, 60°C 20A
(110V) 2 Poles in Series, 70°C 20A
(110V) 3 Poles in Series, 40°C 30A
(110V) 3 Poles in Series, 60°C 30A
(110V) 3 Poles in Series, 70°C 26A
(220V) 2 Poles in Series, 40°C 4A
Show more
Rated operating current DC-13 (Ie):
(24V) 6A / 144W
(48V) 2.8A / 134W
(72V) 1A / 72W
(110V) 0.55A / 60W
(125V) 0.55A / 69W
(220V) 0.27A / 60W
(250V) 0.27A / 68W
(400V) 0.15A / 60W
(500V) 0.13A / 65W
(600V) 0.1A / 60W
Rated insulation voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
according to UL/CSA 600 V
Impulse withstand voltage (Uimp):
6kV
Maximum mechanical switching frequency:
3600 cycles per hour
Rated control circuit voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
Operation in DCin CD 100 ... 250 V
Maneuvering time:
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
DIN rail mounting:
TH35-15 (35 x 15 mm Mounting Bar) according to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Bar) according to IEC 60715
Mounting with screws (not supplied):
2 x M4 screws placed diagonally
Cable sections - main circuit:
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Sections of the cables - auxiliary circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Cable sections - control circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Cable stripping length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Degree of protection:
according to IEC 60529, IEC 60947-1, EN 60529 IP20 Main Terminals
according to IEC 60529, IEC 60947-1, EN 60529 IP20 coils
according to IEC 60529, IEC 60947-1, EN 60529 IP20 Auxiliary Terminals
Clamp Type:
Screw Terminals
UL/CSA technical department
Maximum operating voltage UL/CSA:
Main Circuit 600 V
UL/CSA rated operational power:
(600 V AC) 30 A
UL/CSA Scope:
(120 V AC) Single phase 1-1/2 hp
(200 ... 208 V AC) Three Phase 5 hp
(220 ... 240 V AC) Three Phase 5 hp
(240 V AC) Single phase 3 hp
(440 ... 480 V AC) Three Phase 10 hp
(550 ... 600 V AC) Three Phase 15 hp
UL/CSA main circuit cable cross sections:
Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
UL/CSA auxiliary circuit cable sections:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
UL/CSA control circuit cable sections:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
UL/CSA tightening torque:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Environmental data
Room temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climate resistance:
Category B according to IEC 60947-1 Annex Q
Maximum permitted operating altitude:
Without Derating 3000 m
Impact resistance according to IEC 60068-2-27:
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: At 30 g
Shock Direction: B2 15g
Shock Direction: C1 25g
Shock Direction: C2 25g
Vibration resistance according to IEC 60068-2-6:
4g Closed Position & 2g Open position 5 ... 300 Hz