ALTERNATING CURRENT POWER CONTACTORS
SCHNEIDER ELECTRIC LC1D65AP7 | Schneider Electric
Schneider Electric LC1D65AP7 LC1D65AP7 is a 3-pole TeSys D contactor from Schneider Electric for motor applications up to 30 kW at 400 V. It includes a 230V 50/60 Hz AC coil and integrated 1NO+1NC auxiliary contacts and can be used in applications safety thanks to the certified NC mirror contact. Compact, with DIN rail mounting, it guarantees high reliability and durability. Available worldwide, it is certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium compliant (RoHS/REACH).
€144,00
ABB 1SFL467001R1111 | Abb
Abb 1SFL467001R1111 The AF116 ... AF140 contactors are mainly used for controlling three-phase motors and circuits with power up to 690 V AC, AF146 up to 1000 V AC. These contactors have a block design with 3 main poles/ – control circuit: AC or DC operation with electronic coil interface that accepts a wide range of control voltages. Technical data Number of contacts 3 main NA Number of contacts 0 main NC Number of contacts 1 NA auxiliaries Number of contacts 1 NC auxiliaries Rated Main Circuit Voltage 1000 V operation Rated frequency (f) Main Circuit 50 / 60 Hz
€314,10
ABB 1SBL237001R1100 | Abb AF26-30-00-11
Abb 1SBL237001R1100 - AF26-30-00-11 The AF26-30-00-11 is a 3-pole contactor - 690 V IEC or 600 UL with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) or 15 hp / 480 V UL and switching power circuits up to 45 A (AC-1) or 45 A UL for general use. Thanks to AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), handling large control voltage variations, reducing panel power consumption and ensuring distinct operations in unstable networks. In addition, surge protection is integrated, providing a compact solution. AF contactors have a block-type design, can be easily extended with additional auxiliary contact blocks and a wide range of additional accessories. Technical: Main Contact Number NO: 3 Main Contact Number NC: 0 Number of Auxiliary Contacts NO: 0 Number of Auxiliary Contacts NC: 0 Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1 Rated Operational Voltage: Main Circuit 690V Rated Frequency (f): Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A Rated Operational Current AC-1 (Ie): (690V) 40°C 45A (690V) 60°C 40A (690V) 70°C 32A Rated Operational Current AC-3 (Ie): (415V) 60°C 26A (440V) 60°C 26A (500V) 60°C 23A (690V) 60°C 17A (380 / 400 V) 60 °C 26 A (220 / 230 / 240 V) 60 °C 26 A Rated Operational Current AC-3e (Ie): (415V) 60°C 26A (440V) 60°C 26A (500V) 60°C 23A (690V) 60°C 17A (380 / 400 V) 60 °C 26 A (220 / 230 / 240 V) 60 °C 26 A Rated Operational Power AC-3 (Pe): (400V) 11kW (415V) 11kW (440V) 15kW (500V) 15kW (690V) 15kW (380 / 400 V) 11 kW (220 / 230 / 240V) 6.5kW Rated Operational Power AC-3e (Pe): (415V) 11kW (440V) 15kW (500V) 15kW (690V) 15kW (380 / 400 V) 11 kW (220 / 230 / 240V) 6.5kW Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 1200 cycles per hour Rated Operational Current DC-1 (Ie): (110V) 2 Poles in Series, 40°C 45A (110V) 2 Poles in Series, 60°C 40A (110V) 2 Poles in Series, 70°C 32A (110V) 3 Poles in Series, 40°C 45A (110V) 3 Poles in Series, 60°C 40A (110V) 3 Poles in Series, 70°C 32A (220V) 3 Poles in Series, 40°C 45A (220V) 3 Poles in Series, 60°C 40A (220V) 3 Poles in Series, 70°C 32A (72V) 1-Pole, 40°C 45A Show more Rated Operational Current DC-3 (Ie): (110V) 2 Poles in Series, 40°C 45A (110V) 2 Poles in Series, 60°C 40A (110V) 2 Poles in Series, 70°C 32A (110V) 3 Poles in Series, 40°C 45A (110V) 3 Poles in Series, 60°C 40A (110V) 3 Poles in Series, 70°C 32A (220V) 3 Poles in Series, 40°C 45A (220V) 3 Poles in Series, 60°C 40A (220V) 3 Poles in Series, 70°C 32A (72V) 1-Pole, 40°C 45A Show more Rated Operational Current DC-5 (Ie): (110V) 2 Poles in Series, 40°C 45A (110V) 2 Poles in Series, 60°C 40A (110V) 2 Poles in Series, 70°C 32A (110V) 3 Poles in Series, 40°C 45A (110V) 3 Poles in Series, 60°C 40A (110V) 3 Poles in Series, 70°C 32A (220V) 3 Poles in Series, 40°C 20A (220V) 3 Poles in Series, 60°C 20A (220V) 3 Poles in Series, 70°C 20A (72V) 1-Pole, 40°C 20A Show more Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 690 V acc. to UL/CSA 600V Rated Impulse Withstand Voltage (Uimp): 6kV Maximum Mechanical Switching Frequency: 3600 cycles per hour Rated Control Circuit Voltage (Uc): 50Hz 24...60V 60Hz 24...60V DC Operation 20 ... 60 V
€40,50
ABB 1SFL427001R1311 | Abb
Abb 1SFL427001R1311 Contactors over 100A - AF09…AF2650 three-pole contactors with AC and DC coil - 55 kW (AC-3 400 V). Technical data Number of main contacts NA: 3 Number of main NC contacts: 0 Number of auxiliary contacts NO: 1 Number of NC auxiliary contacts: 1 Rated operating voltage: Main Circuit 690 V Nominal frequency (f): Main Circuit 50 / 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 160 A Rated operating current AC-1 (Ie): (690V) 40°C 160A (690V) 60°C 145A (690V) 70°C 130A Rated operating current AC-3 (Ie): (415V) 55°C 116A (440V) 55°C 116A (500V) 55°C 110A (690V) 55°C 65A (380 / 400 V) 55 °C 116 A (220 / 230 / 240 V) 55 °C 116 A Rated operating current AC-3e (Ie): (415V) 60°C 116A (440V) 60°C 116A (500V) 60°C 110A (690V) 60°C 65A (380 / 400 V) 60 °C 116 A (220 / 230 / 240 V) 60 °C 116 A Rated operating current AC-3 (Pe): (415V) 55kW (440V) 75kW (500V) 75kW (690V) 55kW (380 / 400 V) 55 kW (220 / 230 / 240V) 30kW Rated operating current AC-3e (Pe): (415V) 55kW (440V) 75kW (500V) 75kW (690V) 55kW (380 / 400 V) 55 kW (220 / 230 / 240V) 30kW
€247,65
ABB 1SFL487102R1311 | Abb
Abb 1SFL487102R1311 Contactors over 100A - Four-pole contactors AF09...AF370 and EK550..EK1000-275 A (AC-1 690 V) Technical data Number of main contacts NA: 4 Number of main NC contacts: 0 Number of auxiliary contacts NO: 1 Number of NC auxiliary contacts: 1 Rated operating voltage: Main Circuit 1000V Nominal frequency (f): Main Circuit 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 275 A Rated operating current AC-1 (Ie): (1000V) 40°C 250A (1000V) 55°C 225A (1000V) 60°C 225A (1000V) 70°C 185A (690V) 40°C 275A (690V) 55°C 250A (690V) 60°C 250A (690V) 70°C 200A Rated operating current AC-3 (Ie): (415V) 55°C 190A (440V) 55°C 190A (380 / 400 V) 55 °C 190 A (220 / 230 / 240 V) 55 °C 190 A Rated operating current AC-3 (Pe): (415V) 90kW (440V) 110kW (380 / 400 V) 90 kW (220 / 230 / 240V) 55kW
€410,80
ABB
ABB 1SBL177001R1310 Abb AF16-30-10-13 - bob. 100...250 V AC/DC, aux 1NO Contactors up to 100A - AF09…AF2650 three-pole contactors with AC coil and DC-7.5 kW (AC-3 400 V) Technical data Number of main NA contacts: 3 Number of main NC contacts: 0 Number of NO auxiliary contacts: 1 Number of NC auxiliary contacts: 0 Reference standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1 Rated operating voltage: 690 V Auxiliary Circuit Main Circuit 690 V Rated frequency (f): Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional free air thermal current (Ith): according to IEC 60947-4-1, Open Contactors q = 40 °C 35 A according to IEC 60947-5-1, q = 40 °C 16 A Rated operating current AC-1 (Ie): (690V) 40°C 30A (690V) 60°C 30A (690V) 70°C 26A Rated operating current AC-3 (Ie):(415V) 60°C 18A (440V) 60°C 18A (500V) 60°C 15A (690V) 60°C 10.5A (380 / 400 V) 60 °C 18 A (220 / 230 / 240 V) 60 °C 18 A Rated operating current AC-3e (Ie): (415V) 60°C 18A (440V) 60°C 18A (500V) 60°C 15A (690V) 60°C 10.5A (380 / 400 V) 60 °C 18 A (220 / 230 / 240 V) 60 °C 18 A Rated operating current AC-3 (Pe):(400V) 7.5kW (415V) 9kW (440V) 9kW (500V) 9kW (690V) 9kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Rated operating current AC-3e (Pe): (415V) 9kW (440V) 9kW (500V) 9kW (690V) 9kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Rated operating current AC-15 (Ie): (500V) 2A (690V) 2A (24/127V) 6A (220 / 240V) 4A (400 / 440V) 3A Rated short-time withstand current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 AMaximum breaking capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A Maximum electrical switching frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Rated operating current DC-1 (Ie):(110V) 1-Pole, 40°C 20A (110V) 1-Pole, 60°C 20A (110V) 1-Pole, 70°C 20A (110V) 2 Poles in Series, 40°C 30A (110V) 2 Poles in Series, 60°C 30A (110V) 2 Poles in Series, 70°C 26A (110V) 3 Poles in Series, 40°C 30A (110V) 3 Poles in Series, 60°C 30A (110V) 3 Poles in Series, 70°C 26A (220V) 2 Poles in Series, 40°C 20A Show more Rated operating current DC-3 (Ie): (110V) 1-Pole, 40°C 8A (110V) 1-Pole, 60°C 8A (110V) 1-Pole, 70°C 8A (110V) 2 Poles in Series, 40°C 30A (110V) 2 Poles in Series, 60°C 30A (110V) 2 Poles in Series, 70°C 26A (110V) 3 Poles in Series, 40°C 30A (110V) 3 Poles in Series, 60°C 30A (110V) 3 Poles in Series, 70°C 26A (220V) 2 Poles in Series, 40°C 8A Show more Rated operating current DC-5 (Ie):(110V) 1-Pole, 40°C 4A (110V) 1-Pole, 60°C 4A (110V) 1-Pole, 70°C 4A (110V) 2 Poles in Series, 40°C 20A (110V) 2 Poles in Series, 60°C 20A (110V) 2 Poles in Series, 70°C 20A (110V) 3 Poles in Series, 40°C 30A (110V) 3 Poles in Series, 60°C 30A (110V) 3 Poles in Series, 70°C 26A (220V) 2 Poles in Series, 40°C 4A Show more Rated operating current DC-13 (Ie): (24V) 6A / 144W (48V) 2.8A / 134W (72V) 1A / 72W (110V) 0.55A / 60W (125V) 0.55A / 69W (220V) 0.27A / 60W (250V) 0.27A / 68W (400V) 0.15A / 60W (500V) 0.13A / 65W (600V) 0.1A / 60W Rated insulation voltage (Ui):acc. to IEC 60947-4-1 690 V acc. to IEC 60947-5-1 690 V according to UL/CSA 600 V Impulse withstand voltage (Uimp): 6kV Maximum mechanical switching frequency: 3600 cycles per hour Rated control circuit voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V Operation in DCin CD 100 ... 250 V Maneuvering time: Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 msDIN rail mounting: TH35-15 (35 x 15 mm Mounting Bar) according to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Bar) according to IEC 60715 Mounting with screws (not supplied): 2 x M4 screws placed diagonally Cable sections - main circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm² Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 4 mm² Rigid Stranded 1/2x 1 ... 6 mm² Sections of the cables - auxiliary circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² Cable sections - control circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²Cable stripping length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm Degree of protection: according to IEC 60529, IEC 60947-1, EN 60529 IP20 Main Terminals according to IEC 60529, IEC 60947-1, EN 60529 IP20 coils according to IEC 60529, IEC 60947-1, EN 60529 IP20 Auxiliary TerminalsClamp Type: Screw Terminals UL/CSA technical department Maximum operating voltage UL/CSA: Main Circuit 600 V UL/CSA rated operational power: (600 V AC) 30 A UL/CSA Scope: (120 V AC) Single phase 1-1/2 hp (200 ... 208 V AC) Three Phase 5 hp (220 ... 240 V AC) Three Phase 5 hp (240 V AC) Single phase 3 hp (440 ... 480 V AC) Three Phase 10 hp (550 ... 600 V AC) Three Phase 15 hp UL/CSA main circuit cable cross sections:Rigid Solid 1/2x 16-10 AWG Rigid Stranded 1/2x 16-10 AWG UL/CSA auxiliary circuit cable sections: Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG UL/CSA control circuit cable sections: Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG UL/CSA tightening torque: Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 13 in·lbEnvironmental data Room temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Climate resistance: Category B according to IEC 60947-1 Annex Q Maximum permitted operating altitude: Without Derating 3000 m Impact resistance according to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: At 30 g Shock Direction: B2 15g Shock Direction: C1 25g Shock Direction: C2 25g Vibration resistance according to IEC 60068-2-6: 4g Closed Position & 2g Open position 5 ... 300 Hz
€30,30
FINDER 6K1482304818 |
Finder Industrial contactorFinder Industrial contactor 6K1482304818 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 230 V, operation from 187 to 253 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 187...253 V Contact configuration 3 NO + 1 NO Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 230V Nominal contact voltage 400 V AC Power type AC
€32,70
FINDER 6K1482304810 |
Finder Industrial contactorFinder Industrial contactor 6K1482304810 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 230 V, operation from 187 to 253 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 187...253 V Contact configuration 3 NO + 1 NO Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 230V Nominal contact voltage 400 V AC Power type AC
€20,40
FINDER 6K1482304718 |
Finder Industrial contactorFinder Industrial contactor 6K1482304718 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 230 V, operation from 187 to 253 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 187...253 V Contact configuration 3 NO + 1 NC Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 230V Nominal contact voltage 400 V AC Power type AC
€32,70
FINDER 6K1482304710 |
Finder Industrial contactorFinder Industrial contactor 6K1482304710 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 230 V, operation from 187 to 253 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 187...253 V Contact configuration 3 NO + 1 NC Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 230V Nominal contact voltage 400 V AC Power type AC
€20,40
FINDER 6K1482304318 |
Finder Industrial contactorFinder Industrial contactor 6K1482304318 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical descriptionIndustrial contactor, Contactor, 4 contacts, AC coil, 230 V, operation from 187 to 253 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 187...253 V Contact configuration 4 NO Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 230V Nominal contact voltage 400 V AC Power type AC
€38,85
FINDER 6K1482304310 |
Finder Industrial contactorFinder Industrial contactor 6K1482304310 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 230 V, operation from 187 to 253 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 187...253 V Contact configuration 4 NO Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 230V Nominal contact voltage 400 V AC Power type AC
€25,35
FINDER 6K1481104818 |
Finder Industrial contactorFinder Industrial contactor 6K1481104818 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 110 V, operation from 93.5 to 132 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 93.5...132 V Contact configuration 3 NO + 1 NO Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 110V Nominal contact voltage 400 V AC Power type AC
€32,70
FINDER 6K1481104810 |
Finder Industrial contactorFinder Industrial contactor 6K1481104810 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 110 V, operation from 93.5 to 132 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 93.5...132 V Contact configuration 3 NO + 1 NO Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 110V Nominal contact voltage 400 V AC Power type AC
€20,40
FINDER 6K1481104718 |
Finder Industrial contactorFinder Industrial contactor 6K1481104718 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 110 V, operation from 93.5 to 132 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 93.5...132 V Contact configuration 3 NO + 1 NC Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 110V Nominal contact voltage 400 V AC Power type AC
€32,70
FINDER 6K1481104710 |
Finder Industrial contactorFinder Industrial contactor 6K1481104710 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 110 V, operation from 93.5 to 132 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 93.5...132 V Contact configuration 3 NO + 1 NC Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 110V Nominal contact voltage 400 V AC Power type AC
€20,40
FINDER 6K1481104318 |
Finder Industrial contactorFinder Industrial contactor 6K1481104318 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 110 V, operation from 93.5 to 132 V, rated power 4 VA, ambient temperature -40 to +70 °C Dimensions 45x64.5x61.5 mm Operating range ac 93.5...132 V Contact configuration 4 NO Rated contact current 18 A Ambient temperature -40...70 °C Supply voltage 110V Nominal contact voltage 400 V AC Power type AC
€38,85
FINDER 6K1481104310 |
Finder Industrial contactorFinder Industrial contactor 6K1481104310 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 110 V, operation from 93.5 to 132 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 93.5...132 V Contact configuration 4 NO Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 110V Nominal contact voltage 400 V AC Power type AC
€25,35
FINDER 6K1480244818 |
Finder Industrial contactorFinder Industrial contactor 6K1480244818 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 24 V, operation 20.4 to 26.4 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 20.4...26.4 V Contact configuration 3 NO + 1 NO Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 24V Nominal contact voltage 400 V AC Power type AC
€32,70
FINDER 6K1480244810 |
Finder Industrial contactorFinder Industrial contactor 6K1480244810 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 24 V, operation 20.4 to 26.4 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 20.4...26.4 V Contact configuration 3 NO + 1 NO Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 24V Nominal contact voltage 400 V AC Power type AC
€20,40
FINDER 6K1480244718 |
Finder Industrial contactorFinder Industrial contactor 6K1480244718 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 24 V, operation 20.4 to 26.4 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 20.4...26.4 V Contact configuration 3 NO + 1 NC Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 24V Nominal contact voltage 400 V AC Power type AC
€32,70
FINDER 6K1480244710 |
Finder Industrial contactorFinder Industrial contactor 6K1480244710 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 24 V, operation 20.4 to 26.4 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 20.4...26.4 V Contact configuration 3 NO + 1 NC Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 24V Nominal contact voltage 400 V AC Power type AC
€20,40
FINDER 6K1480244318 |
Finder Industrial contactorFinder Industrial contactor 6K1480244318 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 24 V, operation 20.4 to 26.4 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 20.4...26.4 V Contact configuration 4 NO Rated contact current 18 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 24V Nominal contact voltage 400 V AC Power type AC
€38,85
FINDER 6K1480244310 |
Finder Industrial contactorFinder Industrial contactor 6K1480244310 Commercial description Type 6K.14 industrial contactor, AgSnO2 contacts. Two models available: Type 6K.14.x.xxx.4×10 – 10 A – 400 V AC3 – 11 kW Type 6K.14.x.xxx.4×18 – 18 A – 400 V AC3 – 37 kW Technical description Industrial contactor, Contactor, 4 contacts, AC coil, 24 V, operation from 20.4 to 26.4 V, rated power 4 VA, ambient temperature -40 to +70 °C Operating range ac 20.4...26.4 V Contact configuration 4 NO Rated contact current 10 A Dimensions 45x64.5x61.5 mm Ambient temperature -40...70 °C Supply voltage 24V Nominal contact voltage 400 V AC Power type AC
€25,35