POWER DISTRIBUTION

396 products

  • 5SV36126 | <tc>Siemens</tc>

    SIEMENS 5SV36126 | Siemens

    5SV36126 | Siemens Residual current circuit breaker, 2 pole, type A, In: 25 A, 300 mA, Un AC: 230 V Main features Number of poles - 2 Rated voltage - 230 V Rated current - 25 A Rated fault current - 300 A Mounting method - DIN rail mounting

    €97,83

  • 5SL62067BB | <tc>Siemens</tc>

    SIEMENS 5SL62067BB | Siemens

    Siemens 5SL62067BB Magneto-thermal switch 400V 6kA, 2 poles C, 6A, Italian version Technical datanumber of poles 2pole design 2 polestrip characteristic class Cmechanical lifespan (operating cycles) ● typ. 10 000overvoltage category IIIdegree of pollution 2Voltagetype of voltage of operational voltage ACtype of voltage Use only in alternating current circuits or in direct current circuits .Mixed use is not permittedinsulation voltage (Ui)● for multi-phase operation with AC rated value 440 Voperational current● at 30 °C rated value 6 A● at 40 °C nominal value 5.68 A● at 55 °C nominal value 5.17 A● with AC nominal value 6 A

    €26,52

  • 2CDS200936R0001 | Abb

    ABB 2CDS200936R0001 | Abb

    Abb 2CDS200936R0001 Auxiliary contact. Allows the indication of the position of the device contacts. Suitable for MCB S 200 series, SN 201 series (via the SN201-IH interface module), F 200 RCCB series, RCBO DS201 series, DS202C, DS 200 series. Technical data Function: Auxiliary contact Suitable for: S200 S200M S200P S200S S200 MT S200 MUC S300P Suitable for product class: Miniature Circuit Breaker Power loss: 1 W Maximum 1W Number of NC auxiliary contacts: 1 Number of auxiliary contacts NO: 1 Number of auxiliary contacts c/o (SPDT): 0 Accessory Type: Auxiliary contact Mounting position: left 

    €28,43

  • 1SDA068282R1 | Abb

    ABB 1SDA068282R1 | Abb

    Abb 1SDA068282R1 TMAX XT3S 250 FIXED THREE-POLE SWITCH WITH FRONT TERMINALS AND MAGNETIC RELEASES MA Iu 200 A I3=1200...2400 A Technical data Cable sections - main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour 8000 cycle(s) Mechanical durability: 240 cycles per hour 25000 cycle(s) Number of poles: 3 Opening duration: CB with SOR 15 ms CB with UVR 15ms Multiple Order: 1 piece(s) Power loss: at Nominal Operating Conditions for Pole 13.2 W Rated current (In): 200 A Nominal frequency (f): 50 / 60 Hz Impulse withstand voltage (Uimp): 8kV Instantaneous short-circuit rated current setting (Ii): 1200…2400 A Rated insulation voltage (Ui): 800 V Rated operating voltage: 690VAC 500V DC

    €986,58

  • 2CMA103572R1000 | Abb

    ABB 2CMA103572R1000 | Abb

    Abb 2CMA103572R1000 C11 is the simple and compact energy meter for insertion in 230 V AC networks up to 40 A. It is CE approved, equipped with outputs with pulse and alarm function, optional MID approval, 1 DIN module Technical data Function: Electricity meter Subfunction: Steel Nominal voltage (Ur): 230 V Voltage range: 184…264 V Rated current (In): 5 A Maximum 40 A Rated current: 5 A Nominal frequency (f): 50 / 60 Hz Power consumption (@Pcons): 0.22W Power loss: 0.22W Communication interface: It is not Precision: Active Energy Cl. ±1% (or B for MID meters) Measuring Instrument Conformity: IEC 62053-22 Meter Tariff Rating: One Tariff Pulse Output Rate: 1000 Number of poles: 1 Number of phases: Single phase

    €75,80

  • 1SDA067404R1 | Abb

    ABB 1SDA067404R1 | Abb

    Abb 1SDA067404R1 TMAX XT1C 160 FIXED FOUR-POLE SWITCH WITH FRONT TERMINALS AND THERMO-MAGNETIC RELEASES TMD R 63-630 A Technical data Cable sections - main circuit: Busbar 45.5 ... 80 mm² Current type: AC/DC Electrical life: 120 cycles per hour 8000 cycle(s) Mechanical durability: 240 cycles per hour 25000 cycle(s) Number of poles: 4 Opening duration: CB with SOR 15 ms CB with UVR 15ms Multiple Order: 1 piece(s) Power loss: at Nominal Operating Conditions for Pole 4.3 W Rated current (In): 63 A Nominal frequency (f): 50 / 60 Hz Impulse withstand voltage (Uimp): 8kV Instantaneous short-circuit rated current setting (Ii): 630 A Rated insulation voltage (Ui): 800 V

    €370,65

  • 1SCA120518R1001 | Abb

    ABB 1SCA120518R1001 | Abb

    Abb 1SCA120518R1001 OT160EV04 section 4P 160A power switch, with pistol handle, mounting on bottom plate Technical data Rated operating current AC-21A (Ie): (380 ... 415 V) 200 A (500V) 200A (690V) 200A Rated operating current AC-22A (Ie): (380 ... 415 V) 200 A (500V) 200A (690V) 160A Rated operating current AC-23A (Ie): (380 ... 415 V) 160 A (500V) 160A (690V) 160A Rated operating current AC-23a (Pe): (220 ... 240 V) 48 kW (400 ... 415 V) 88 kW (500V) 112kW (690V) 144kW Conventional free air thermal current (Ith): q = 40 °C 200 A Conventional thermal current (Ithe): Fully Enclosed 160A Impulse withstand voltage (Uimp): 12kV Rated insulation voltage (Ui): according to IEC/EN 60664-1 1000 V Rated operating voltage: Main Circuit 1000V Rated short circuit making capacity (Icm): (690V) 30kA Rated short-time withstand current (Icw): for 1 s 8 kA Power loss: at Nominal Operating Conditions for Pole 3.2 W Degree of pollution: 3

    €144,59

  • 1SDA068059R1 | Abb

    ABB 1SDA068059R1 | Abb

    Abb 1SDA068059R1 TMAX XT3N 250 FIXED THREE-POLE SWITCH WITH FRONT TERMINALS AND THERMO-MAGNETIC RELEASES TMD R 250-2500 A Technical data Cable sections - main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour 8000 cycle(s) Mechanical durability: 240 cycles per hour 25000 cycle(s) Number of poles: 3 Opening duration: CB with SOR 15 ms CB with UVR 15ms Multiple Order: 1 piece(s) Power loss: at Nominal Operating Conditions for Pole 17.8 W Rated current (In): 250 A Nominal frequency (f): 50 / 60 Hz Impulse withstand voltage (Uimp): 8kV Instantaneous short-circuit rated current setting (Ii): 2500 A Rated insulation voltage (Ui): 800 V Rated operating voltage: 690VAC 500V DC Rated service short circuit capacity (Ics): (220VAC) 50kA (230 V AC) 50 kA (240VAC) 50kA (380VAC) 27kA (415VAC) 36kA (440VAC) 19kA (500VAC) 15kA (525VAC) 9.75kA (690VAC) 3.75kA (250 V DC) 2 Poles in Series 36 kA

    €897,12

  • 2CDS252001R0064 | Abb

    ABB 2CDS252001R0064 | Abb

    Abb 2CDS252001R0064 The System pro M compact S200 miniature circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. Technical data Reference standards: IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 Intervention feature: C Rated operating voltage: according to IEC 60898-1 400 V AC according to IEC 60898-1 400 V according to IEC 60947-2 440 V AC Operating voltage: Maximum (Incl. Tolerance) 125 V DC Maximum (Incl. Tolerance) 440 V AC Minimum 12V AC Minimum 12V DC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4kV at 2000 m 5 kV at Sea Level 6.2 kV Dielectric test voltage: 50/60 Hz-1 min: 2 kV Input voltage type: AC/DC Rated current (In): 6 A Rated short circuit power: (AC) 6kA (DC) 6kA (400VAC) 6kA (400V) 6kA Rated extreme short circuit power (Icu): (125V DC) 10kA (230 V AC) 20 kA (400VAC) 10kA (440VAC) 10kA (48V DC) 20kA (230V) 20kA (400V) 10kA

    €68,47

  • 1SDA063439R1 | Abb

    ABB 1SDA063439R1 | Abb

    Abb 1SDA063439R1 TMAX T5V 630 1150V AC FIXED THREE-POLE SWITCH WITH FRONT TERMINALS FOR Cu CABLES AND THERMO-MAGNETIC RELEASES TMA R 500 I3=2500...5000 A Technical data Electrical life: 5000 cycle(s) 60 cycles per hour Mechanical durability: 20000 cycle(s) 120 cycles per hour Number of poles: 3 Power loss: at Nominal Operating Conditions for Pole 28.8 W Rated current (In): 500 A Impulse withstand voltage (Uimp): 8kV Rated insulation voltage (Ui): 1000 V Rated operating voltage: 1150VAC 1000V DC Rated service short circuit capacity (Ics): (1000VAC) 10kA (1150VAC) 6kA Rated extreme short circuit power (Icu): (1000VAC) 20kA (1150VAC) 12kA Rated uninterrupted current (Iu): 630 A Release: TMA Release Type: TM

    €5.330,64

  • 1SDA054897R1 | Abb

    ABB 1SDA054897R1 | Abb

    Abb 1SDA054897R1 Operator motor 220...250V AC-DC T4-T5 Technical data Configuration Type Loose or configurable Current Type AC/DC 220 ... 250 V AC  220 ... 250 V DC Rated Voltage (Ur) IEC Standards

    €897,12

  • 1SDA062102R1 | Abb

    ABB 1SDA062102R1 | Abb

    Abb 1SDA062102R1 2 OPEN-CLOSED EXCHANGE CONTACTS V <(><<)> 400V AC T7-T7M-X1 Technical data Configuration type: Loose or Configurable Gross volume: 1,450 cm³ Number of auxiliary contacts c/o (SPDT): 2 Reference standards: IEC

    €43,16

Footer image

© 2025 DMS S.R.L. VAT IT04742820618

DMSTECHMART is not a distributor or representative of the brands featured on this site. All product names, logos and trademarks are the property of their respective owners. All company, product and service names used on this site are for identification purposes only.

    • American Express
    • Apple Pay
    • Bancontact
    • Google Pay
    • iDEAL
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account