ENGINE SAVER
-
SIEMENS 3RV20110KA10 | Siemens
Siemens 3RV20110KA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 0.9...1.25 A release N 16 A screw terminal standard operating capacity SIRIUS circuit breaker 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized due to their low leakage thermal, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.
€43,00
-
EATON 072735 | Eaton
Eaton 072735Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip
€69,15
-
SIEMENS 3RV20110JA10 | Siemens
Siemens 3RV20110JA10circuit breaker size S00 for motor protection, CLASS 10 release A 0.7...1 A release N 13 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For Motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low heat loss, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.
€42,70
-
SCHNEIDER ELECTRIC GV2ME21 | Schneider Electric
Schneider Electric GV2ME21GV2ME21 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 9 kW motors at 400 V and a breaking capacity Icu of 15 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME21 is a TeSys GV motor circuit breaker from Schneider Electric designed for 9 kW motorized applications at 400 V. It offers thermal magnetic protection with a 17-23 A thermal setting range, 12 xIn magnetic trip and 15 kA Icu breaking capacity at 400 V. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium compliant (RoHS/REACH).
€68,35
-
ABB EP 883 1 | Abb
Abb EP 883 1MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications
€65,70
-
SIEMENS 3RV20111CA10 | Siemens
Siemens 3RV20111CA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 1.8...2.5 A release N 33 A screw terminal standard operating capacity SIRIUS circuit breaker 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized due to their low leakage thermal, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.
€43,00
-
ABB EP 088 7 | Abb
Abb EP 088 7MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications
€59,05
-
ABB EP 090 3 | Abb
Abb EP 090 3MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications
€60,65
-
SCHNEIDER ELECTRIC GV2ME22 | Schneider Electric
Schneider Electric GV2ME22GV2ME22 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 11 kW motors at 400 V and a breaking capacity Icu of 15 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME22 is a TeSys GV motor circuit breaker from Schneider Electric designed for 11 kW motorized applications at 400 V. It offers thermal magnetic protection with a thermal setting range of 20-25 A, magnetic tripping at 12 xIn and Icu breaking capacity 15 kA at 400 V. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).
€90,60
-
EATON 072738 | Eaton
Eaton 072738Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip
€69,15
-
SCHNEIDER ELECTRIC GV2ME06 | Schneider Electric
Schneider Electric GV2ME06GV2ME06 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 0.37-0.55 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME06 is a TeSys GV motor circuit breaker from Schneider Electric designed for 0.37-0.55 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal setting range of 1-1.6 A, magnetic tripping at 12 xIn and high breaking capacity Icu 100 kA at 400 V. Start-stop control via button guaranteed for 100,000 AC-3 415V cycles. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).
€51,95
-
SCHNEIDER ELECTRIC GV2ME07 | Schneider Electric
Schneider Electric GV2ME07GV2ME07 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 0.75 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME07 is a TeSys GV motor circuit breaker from Schneider Electric designed for 0.75 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal regulation range of 1.6-2.5 A, magnetic tripping at 12 xIn and a high breaking capacity Icu 100 kA at 400 V. Start-stop control via push button guaranteed for 100,000 AC-3 415V cycles. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium compliant (RoHS/REACH).
€51,95
-
LOVATO SM1P1400 | Lovato
Lovato SM1P1400Magneto-thermal motor protection switches with high breaking capacity. The various settings from 0.1 to 40A allow the control and protection of motors up to 22kW (400V). The SM1P... switches have dimensions compliant with the DIN43880 standard which allow them to be mounted in all modular enclosures on the market. They are suitable for isolation in compliance with IEC/EN 60947 standards and can be padlocked in the OFF position without using accessories. The high breaking capacity values allow, in most installations, to avoid the use of fuses.
€43,85
-
SCHNEIDER ELECTRIC GV2ME08 | Schneider Electric
Schneider Electric GV2ME08GV2ME08 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 1.1-1.5 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME08 is a TeSys GV motor circuit breaker from Schneider Electric designed for 1.1-1.5 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal setting range of 2.5-4 A, magnetic tripping at 12 xIn and a high breaking capacity Icu 100 kA at 400 V. Start-stop control via push button guaranteed for 100,000 AC-3 415V cycles. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).
€51,95
-
ABB EP 089 5 | Abb
Abb EP 089 5MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications
€59,05
-
SCHNEIDER ELECTRIC GV2ME05 | Schneider Electric
Schneider Electric GV2ME05GV2ME05 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 0.25 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME05 is a TeSys GV motor circuit breaker from Schneider Electric designed for 0.25 kW motorized applications at 400 V. It meets thermal magnetic protection with a 0.63-1 A thermal setting range, 12 xIn magnetic tripping and a high breaking capacity Icu 100 kA at 400 V. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).
€51,95
-
SIEMENS 3RV20414KA10 | Siemens
Siemens 3RV20414KA10circuit breaker frame size S3 for motor protection, CLASS 10 release A 57...75 A release N 975 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.
€240,80
-
SCHNEIDER ELECTRIC GV2ME10 | Schneider Electric
Schneider Electric GV2ME10GV2ME10 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 2.2 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME10 is a TeSys GV motor circuit breaker from Schneider Electric designed for 2.2 kW motorized applications at 400 V. It meets thermal magnetic protection with a 4-6.3 A thermal regulation range, 12 xIn magnetic tripping and high switching power Icu interruption 100 kA at 400 V. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).
€51,95
-
ABB 1SAM250000R1007 | Abb MS116-2.5
Abb Motor protectors and thermal relays-Protection switches 1SAM250000R1007 Motor protectors and thermal relays-Class 10 thermal magnetic protection switches-MS116 class 10 motor protectors. Technical dataRated service short-circuit capacity (Ics):(230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 10 kA(500 V AC) 10 kA(690 V AC) 5 kA Rated extreme short-circuit capacity (Icu):(230 V AC) 75 kA(400 V AC) 75 kA(440 V AC) 30 kA(500 V AC) 20 kA(690 V AC) 10 kA Setting instantaneous rated short-circuit current (Ii):31.3 ASetting range:1.6 ... 2.5 ARated operating current AC-3 (Pe) :(400 V) Three Phases 0.75 kWRated operating current AC-3e (Pe):(400 V) Three Phases 0.75 kW Rated operating voltage: Main Circuit 690 V ACRated operating current (Ie):2.5 ARated operating current AC-3 (Ie):2.5 ARated operating current AC-3e (Ie):2.5 A Nominal frequency (f): Main Circuit 50 HzMain Circuit 60 HzImpulse withstand voltage (Uimp):Main Circuit 6 kVRated insulation voltage (Ui):690 VLeakage power: at Nominal Operating Conditions for Pole 0.7 ... 1.8 W Number of poles: 3Conventional free air thermal current (Ith): Main Circuit 2.5 A Degree of protection: Housing IP20Main Circuit Terminals IP10 Pollution degree: 3Electrical life:100000 cycle (i)Mechanical life:100000 cycle (i)Terminal type:Screw TerminalsCable sections - main circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²Flexible 1/2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 4 mm²Tightening torque:Main Circuit 0.8 ... 1.2 N·mCable stripping length:Main Circuit 9 mm
€59,05
-
SCHNEIDER ELECTRIC GV3P50 | Schneider Electric Automatic circuit breaker
Schneider Electric GV3P automatic circuit breaker - 50 A - everlink GV3P50 GV3P50 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 22 kW motors at 400 V and a high breaking capacity Icu 50 kA. Start-stop control via rotary handle guaranteed for 50,000 cycles AC-3 415V. GV3P50 is a TeSys GV motor circuit breaker from Schneider Electric designed for 22 kW motorized applications at 400 V. It meets thermal magnetic protection with a 37-50 A thermal setting range, 14 xIn magnetic tripping and a high Icu breaking capacity 50 kA at 400 V. Start-stop control via rotary handle guaranteed for 50,000 cycles AC-3 415V. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium compliant (RoHS/REACH). Range: TeSys DecaProduct Name: TeSys GV3TeSys DecaProduct Type: Automatic circuit breakerDevice Name: GV3PApplication: Motor protectionTrip Release Technology : Circuit breakerNumber of Poles: 3PMains Type: ACUsage Category AC-3 conforming to IEC 60947-4-1Mains Frequency: 50/60 Hz conforming to IEC 60947 -4-1Fixing type 35 mm symmetrical DIN rail: clippedPanel: screwed (with 3 x M4 screws)Motor power in kW 22 kW at 400/415 V AC 50/60 Hz30 kW at 500 V AC 50/60 Hz45 kW at 690 V AC 50/60 HzBreaking capacity: 100 kA Icu compliant with IEC 60947-2 at 230/240 V AC 50/60 Hz 50 kA Icu compliant with IEC 60947-2 at 400/415 V AC 50/60 Hz50 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 Hz12 kA Icu compliant with IEC 60947-2 at 500 V AC 50/60 Hz6 kA Icu compliant with IEC 60947-2 at 690 V AC 50/60 HzRated Service Breaking Capacity [Ics]:100 % conforming to IEC 60947-2 at 230/240 V AC 50/60 Hz100 % conforming to IEC 60947-2 at 400/415 V AC 50/60 Hz100 % conforming to IEC 60947-2 at 440 V AC 50/60 Hz50 % conforming to IEC 60947-2 at 500 V AC 50/60 Hz50 % conforming to IEC 60947-2 at 690 V AC 50/60 HzControl Type : Rotary handleNominal Current [In]: 50 AProtection Regulation RangeThermal37…50 A conforming to IEC 60947-4-1Magnetic Trip Current: 700 A
€168,75
-
SIEMENS 3RV20111GA100BA0 | Siemens special type circuit breaker
Siemens special type circuit breaker 3RV20111GA100BA0 Special type automatic circuit breaker size S00 for motor protection, CLASS 10 release A 4.5...6.3 A release N 82 A screw terminal standard operating capacity ambient temperature -50 °C 500 cycles maneuvering General technical data frame size of the circuit breaker S00 frame size of the company-specific combinable contactor S00, S0 product extension auxiliary contacts Yes power dissipation [W] at nominal current value ● with AC in hot operating state 7.25 W ● with AC in hot operating state for each pole 2.4 W insulation voltage at pollution degree 3 at AC rated value 690 V impulse withstand voltage rated value 6 kV shock resistance according to IEC 60068-2-27 25g / 11 ms mechanical lifespan (operating cycles) ● of the main contacts typ. 500 ● of the auxiliary contacts typ. 500 electrical lifespan (operating cycles) typ. 500 reference code according to IEC 81346-2:2009 Q RoHS Directive (date) 10/01/2009 Environmental conditions installation altitude for altitude above sea level. max. 2 000 m ambient temperature ● during operation -50 ... +60 °C ● during storage -50 ... +80 °C ● during transport - 50 ... +80 °C relative humidity during operation 10 ... 95 % Main electrical circuit number of poles for main circuit 3 settable trip value for current-dependent overload release current 4.5 ... 6.3 A operating voltage ● rated value 20 ... 690 V ● with AC-3 rated value max. 690 V operating frequency rated value 50 ... 60 Hz operating current rated value 6.3 A operating current ● with AC-3 at 400 V rated value 6.3 A
€87,80
-
SIEMENS 3rv20111ga10 | Automatic Circuit Breaker For Motor Protection
SIEMENS Circuit breaker size S00 for motor protection 3RV20111GA10 Circuit breaker size S00 for motor protection, CLASS 10 release A 4.5...6.3 A release N 82 A screw terminal standard operating capacity. General technical dataframe size of the circuit breaker S00frame size of the combinable contactor company-specificS00, S0expansion of the product auxiliary switch block Yespower loss [W] at rated current value● with AC in hot operating state 7.25 W● with AC in hot operating state per pole 2, 4 Winsulation voltage at pollution degree 3 with ACrated value 690 Vimpulse withstand voltage rated value 6 kVshock resistance according to IEC 60068-2-27 25g / 11 msmechanical lifespan (operating cycles)● of the main contacts typ. 100 000● of auxiliary contacts typ. 100 000electrical lifespan (switching cycles) typ. 100 000type of explosion protection according to the ATEXProduct Directive 2014/34/EUEx II (2) GDcertificate of suitability according to the ATEX Product Directive2014/34 /UEDMT 02 ATEX F 001reference code according to IEC 81346-2:2009 QRoHS Directive (date) 10/01/2009Environmental conditionsinstallation altitude for altitude above sea level max. 2 000 mambient temperature● during operation -20 ... +60 °C● during storage -50 ... +80 °C● during transport - 50 ... +80 °Crelative humidity during operation 10 ... 95 %Main electrical circuitnumber of poles per main circuit 3trip value settable for current of thecurrent-dependent overload release 4.5 ... 6.3 Aoperating voltage● rated value 20 . .. 690 V● with AC-3 rated value max. 690 V● with AC-3e rated value max. 690 Voperating frequency nominal value 50 ... 60 Hz
€43,00
-
SIEMENS 3RV20111AA10 | Siemens Circuit breaker size S00 for motor protection
SIEMENS Circuit breaker size S00 for motor protection 3RV20111AA10 Automatic circuit breaker size S00 for motor protection, CLASS 10 release A 1.1...1.6 A release N 21 A screw terminal standard operating power. General technical dataframe size of the circuit breaker S00frame size of the combinable contactor company specificS00, S0product extension auxiliary contacts Yespower dissipation [W] at rated current value● with AC in hot operating state 7.25 W● with AC in hot operating state per pole 2.4 Winsulation voltage with pollution degree 3 with ACrated value690 Vimpulse withstand voltage rated value 6 kVshock resistance according to IEC 60068-2-27 25g / 11 msmechanical lifespan (operating cycles)● of the main contacts typ. 100 000● of auxiliary contacts typ. 100 000electrical lifespan (switching cycles) typ. 100 000type of explosion protection according to the ATEXProduct Directive 2014/34/EUEx II (2) GDcertificate of suitability according to the ATEX Product Directive2014/34 /UEDMT 02 ATEX F 001reference code according to IEC 81346-2:2009 QRoHS Directive (date) 10/01/2009Environmental conditionsinstallation altitude for altitude above sea level max. 2 000 mambient temperature● during operation -20 ... +60 °C● during storage -50 ... +80 °C● during transport - 50 ... +80 °Crelative humidity during operation 10 ... 95 %Main electrical circuitnumber of poles per main circuit 3tripping value settable for current of thecurrent-dependent overload release 1.1 ... 1.6 Aoperating voltage● rated value 20 ... 690 V● with AC-3 rated value max. 690 V● with AC-3e rated value max. 690 Voperating frequency rated value 50 ... 60 Hz
€43,00
-
SIEMENS 3RV20111DA10 | SIEMENS SIRIUS Automatic Switch Size S00
SIEMENS SIRIUS 3RV2 Circuit breaker 3RV20111DA10 Automatic circuit breaker size S00 for motor protection, CLASS 10 release A 2,2...3,2 A release N 42 A screw terminal standard operating power. General information product brand SIRIUSproduct designation Circuit breakerproduct design For motor protectionproduct type designation 3RV2 General technical data frame size of circuit breaker S00frame size of company-specific combinable contactor S00, S0product expansion auxiliary switch block Yes power loss [W] at rated current value● with AC in hot operating state 7.25 W● with AC in hot operating state per pole 2.4 Wvoltage insulation with pollution degree 3 with AC rated value 690 Vimpulse withstand voltage rated value 6 kVshock resistance according to IEC 60068-2-27 25g / 11 ms mechanical lifespan (operating cycles)● of the main contacts typ. 100 000● of auxiliary contacts typ. 100 000electrical lifespan (switching cycles) typ. 100 000type of explosion protection according to the ATEX Product Directive 2014/34/EU Ex II(2) GDcertificate of suitability according to the ATEX Product Directive 2014/34/EU DMT 02 ATEX F 001reference code according to IEC 81346-2:2009 QRoHS Directive (date) 10/01/2009
€33,80