FREE SHIPPING throughout Europe

ENGINE SAVER

166 products


  • 3RV20214CA10 | Siemens

    SIEMENS 3RV20214CA10 | Siemens

    Siemens 3RV20214CA10circuit breaker frame size S0 for motor protection, CLASS 10 release A 16 ... 22 A release N 286 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €59,39

  • 3RV20314WA10 | Siemens

    SIEMENS 3RV20314WA10 | Siemens

    Siemens 3RV20314WA10circuit breaker frame size S2 for motor protection, CLASS 10 release A 42 ... 52 A release N 741 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €203,24

  • EP 091 1 | Abb

    ABB EP 091 1 | Abb

    Abb EP 091 1MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €69,01

  • EP 943 3 | Abb

    ABB EP 943 3 | Abb

    Abb EP 943 3MS325 4 0-6 3A INTERR. MOTOR SAVER. 100KA

    €65,55

  • EP 888 0 | Abb

    ABB EP 888 0 | Abb

    Abb EP 888 0MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €108,11

  • 3RV20211DA10 | Siemens

    SIEMENS 3RV20211DA10 | Siemens

    Siemens 3RV20211DA10circuit breaker frame size S0 for motor protection, CLASS 10 release A 2,2...3,2 A release N 42 A screw terminal standard operating capacity SIRIUS circuit breaker 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized due to their low heat loss , for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €65,95

  • 3RV20110FA10 | Siemens

    SIEMENS 3RV20110FA10 | Siemens

    Siemens 3RV20110FA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 0.35...0.5 A release N 6.5 A screw terminal standard operating capacity Circuit-breaker automatic SIRIUS 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized thanks to their low heat dispersion, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €54,16

  • 3RV20110AA10 | Siemens

    SIEMENS 3RV20110AA10 | Siemens

    Siemens 3RV20110AA10circuit breaker frame size S00 for motor protection, Class 10 release A 0.11...0.16 A release N 2.1 A screw terminal standard operating capacity Circuit-breaker automatic SIRIUS 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized thanks to their low heat dispersion, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €53,79

  • 3RV20110GA10 | Siemens

    SIEMENS 3RV20110GA10 | Siemens

    Siemens 3RV20110GA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 0.45...0.63 A release N 8.2 A screw terminal standard operating capacity Circuit-breaker automatic SIRIUS 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized thanks to their low heat loss, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €54,28

  • EP 086 1 | Abb

    ABB EP 086 1 | Abb

    Abb EP 086 1MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €59,05

  • 3RV20111FA10 | Siemens

    SIEMENS 3RV20111FA10 | Siemens

    Siemens 3RV20111FA10circuit breaker size S00 for motor protection, CLASS 10 release A 3.5...5 A release N 65 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For Motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low heat loss, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €55,04

  • 3RV20214FA10 | Siemens

    SIEMENS 3RV20214FA10 | Siemens

    Siemens 3RV20214FA10circuit breaker frame size S0 for motor protection, CLASS 10 release A 34...40 A release N 480 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €156,10

  • 248397 | Eaton

    EATON 248397 | Eaton

    Eaton 248397Switch for motor load protection. Sectioning displayed by red-green contact status indicator. Thanks to the suitability for sectioning according to IEC/EN 60947 can be used as the main switch. Design, dimensions and modularity compliant with PL. Particularly suitable for installation in enclosures with modular windows. Self-protected without the use of a back-up pre-fuse up to 4 A. Double connection possibility (battery cable) both at the top and bottom. Clamp still accessible even with bar inserted.

    €38,74

  • 3RV20314EA10 | Siemens

    SIEMENS 3RV20314EA10 | Siemens

    Siemens 3RV20314EA10circuit breaker frame size S2 for motor protection, CLASS 10 release A 22...32 A release N 416 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €154,85

  • 072737 | Eaton

    EATON 072737 | Eaton

    Eaton 072737PKZM0-4 072737 EATON MOELLER Motor protection circuit breaker, 3p, Ir 2.5-4A, screw connection

    €69,13

  • GV2ME04 | Schneider Electric

    SCHNEIDER ELECTRIC GV2ME04 | Schneider Electric

    Schneider Electric GV2ME04GV2ME04 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 0.12-0.18 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME04 is a TeSys GV motor circuit breaker from Schneider Electric designed for 0.12-0.18 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal setting range of 0.4-0.63 A, magnetic tripping at 12 xIn and a high breaking capacity Icu 100 kA at 400 V. Start-stop control via push button guaranteed for 100,000 AC-3 415V cycles. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).

    €62,59

  • GV3P25 | Schneider Electric

    SCHNEIDER ELECTRIC GV3P25 | Schneider Electric

    Schneider Electric GV3P25GV3P25 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 11 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via rotary handle guaranteed for 50,000 cycles AC-3 415V. GV3P25 is a TeSys GV motor circuit breaker from Schneider Electric designed for 11 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal regulation range of 17-25 A, magnetic tripping at 14 xIn and a high breaking capacity Icu 100 kA at 400 V. Start-stop control via rotary handle guaranteed for 50,000 cycles AC-3 415V. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).

    €161,29

  • 417306 | Legrand

    LEGRAND 417306 | Legrand

    Legrand 417306Three-phase thermal-magnetic motor protection with lever control - Vn=690V - Ir=1.6-2.5A - Im= 32.5A - Icu= 100kA (at 415Vac) - Pw motors 0.75W. Complies with IEC 60947-1, IEC 60947-2, IEC 60947-4 standards. Adjustable thermal release. Magnetic release calibrated at 13Ie max.

    €96,89

  • 3RV20211BA10 | Siemens

    SIEMENS 3RV20211BA10 | Siemens

    Siemens 3RV20211BA10circuit breaker size S0 for motor protection, CLASS 10 release A 1,4...2 A release N 26 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For Motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low heat loss, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. As a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €65,95

  • 3RV20111JA10 | Siemens

    SIEMENS 3RV20111JA10 | Siemens

    Siemens 3RV20111JA10circuit breaker size S00 for motor protection, CLASS 10 release A 7...10 A release N 130 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €55,09

  • 3RV20111AA20 | Siemens

    SIEMENS 3RV20111AA20 | Siemens

    Siemens 3RV20111AA20circuit breaker frame size S00 for motor protection, CLASS 10 release A 1.1...1.6 A release N 21 A spring terminal standard operating capacity SIRIUS circuit breaker 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized due to their low leakage thermal, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €61,61

  • GV3P40 | Schneider Electric

    SCHNEIDER ELECTRIC GV3P40 | Schneider Electric

    Schneider Electric GV3P40GV3P40 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal magnetic protection of 18.5 kW motors at 400 V and a high breaking capacity Icu 50 kA. Start-stop control via rotary handle guaranteed for 50,000 cycles AC-3 415V. GV3P40 is a TeSys GV motor circuit breaker from Schneider Electric designed for 18.5 kW motorized applications at 400 V. It meets thermal magnetic protection with a 30-40 A thermal setting range, 14 xIn magnetic tripping and a high switching power Icu 50 kA interruption at 400 V. Start-stop control via rotary handle guaranteed for 50,000 cycles AC-3 415V. Available worldwide, it is certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium compliant (RoHS/REACH).

    €169,64

  • 3RV20314JA10 | Siemens

    SIEMENS 3RV20314JA10 | Siemens

    Siemens 3RV20314JA10circuit breaker frame size S2 for motor protection, CLASS 10 release A 54...65 A release N 845 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €204,61

  • EP 884 9 | Abb

    ABB EP 884 9 | Abb

    Abb EP 884 9MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €67,39

© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?