FREE SHIPPING throughout Europe.

ENGINE SAVER

166 products


  • <span style="background-color: rgb(247, 247, 247);">3RV20111GA20 | Siemens</span>

    SIEMENS 3RV20111GA20 | Siemens

    Siemens 3RV20111GA20 circuit breaker size S00 for motor protection, CLASS 10 trip A 4.5...6.3 A trip N 82 A spring clamp standard switching power Circuit breaker SIRIUS 3RV2 For motor protection, for safe switch-off in the event of a short circuit and for overload protection of consumers and the system, as well as for the safe separation of the system from the mains. Thanks to their low heat loss, the compact and tropicalized circuit breakers are optimized for use in start-ups, of course also for IE3/IE4 motors and equally for direct current switching. Of course, international approvals (e.g. IEC and UL/CSA) and designs for applications in hazardous areas (ATEX or IEC Ex) are available. Device variants are available for motor protection (also with overload relay function), system protection, short-circuit protection of combination starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for a quick, maintenance-free and vibration-resistant connection and optionally with a built-in auxiliary contact block. All accessories such as auxiliary contact blocks, auxiliary trip devices, signal contact blocks, etc., are uniformly suitable for all design sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.nThe 3RV2 circuit breakers replace the proven 3RV1 series.n Simple, efficient, timeless - the SIRIUS modular system.

    €61,44

  • <span style="background-color: rgb(247, 247, 247);">3RV20110BA10 | Siemens</span>

    SIEMENS 3RV20110BA10 | Siemens

    Siemens 3RV20110BA10 circuit breaker size S00 for motor protection, CLASS 10 trip A 0.14...0.2 A trip N 2.6 A screw terminal standard switching power Circuit breaker SIRIUS 3RV2 For motor protection, for safe switch-off in the event of a short circuit and for load and system overload protection, as well as for the safe separation of the system from the mains.n  Thanks to their low heat loss, the compact and tropicalized circuit breakers are optimized for use in start-ups, of course also for IE3/IE4 motors and equally for direct current switching. Of course, international approvals (e.g. IEC and UL/CSA) and designs for applications in hazardous areas (ATEX or IEC Ex) are available. Device variants are available for motor protection (also with overload relay function), system protection, short-circuit protection of combination starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for a quick, maintenance-free and vibration-resistant connection and optionally with a built-in auxiliary contact block. All accessories such as auxiliary contact blocks, auxiliary trip devices, signal contact blocks, etc., are uniformly suitable for all design sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.n3RV2 circuit breakers replace the proven 3RV1 series.n Simple, efficient, timeless - the SIRIUS modular system.

    €53,79

  • <span style="background-color: rgb(247, 247, 247);">3RV20210KA10 | Siemens</span>

    SIEMENS 3RV20210KA10 | Siemens

    Siemens 3RV20210KA10 circuit breaker size S0 for motor protection, CLASS 10 trip A 0.9...1.25 A trip N 16 A screw terminal standard switching power Circuit breaker SIRIUS 3RV2 For motor protection, for safe switch-off in the event of a short circuit and for overload protection of consumers and the system, as well as for the safe separation of the system from the mains. Thanks to their low heat loss, the compact and tropicalized circuit breakers are optimized for use in start-ups, of course also for IE3/IE4 motors and equally for direct current switching. Of course, international approvals (e.g. IEC and UL/CSA) and designs for applications in hazardous areas (ATEX or IEC Ex) are available. All accessories such as auxiliary contact blocks, auxiliary trip devices, signal contact blocks, etc., are uniformly suitable for all design sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.n3RV2 circuit breakers replace the proven 3RV1 series.n Simple, efficient, timeless - the SIRIUS modular system.

    €64,64

  • <span style="background-color: rgb(247, 247, 247);">SM1R1800 | Lovato</span>

    LOVATO SM1R1800 | Lovato

    Lovato SM1R1800 Circuit breakers with high breaking capacity. The various calibrations from 0.1 to 40A allow the control and protection of motors up to 22kW (400V). The SM1R switches... They have a magnetic tripping indicator as standard, which allows you to avoid dangerous closing manoeuvres in the presence of previously interrupted short circuits. The SM1R switches... they are Type E approved according to UL508 (approval available for calibrations from 0.1 to 6.5A, other calibrations are being approved). They are suitable for disconnection in accordance with IEC/EN 60947 standards and can be padlocked in the OFF position without the use of accessories. The high breaking capacity values make it possible to avoid the use of fuses in most installations.

    €48,20

  • SM2R6300 | Lovato

    LOVATO SM2R6300 | Lovato

    Lovato SM2R6300MOTOR PROTECTION SWITCH, INT. POWER ICU AT 400V = 50KA, 45...63A

    €175,25

  • SM1X18200R | Lovato

    LOVATO SM1X18200R | Lovato

    Lovato SM1X18200RIP65 PADLOCKABLE DOOR LOCK HANDLE FOR SM1R... YELLOW/RED COLOR COMPLETE WITH LENGTH ROD. 200MM.

    €34,79

  • SM1P2500 | Lovato

    LOVATO SM1P2500 | Lovato

    Lovato SM1P2500Magneto-thermal motor protection switches with high breaking capacity. The various settings from 0.1 to 40A allow the control and protection of motors up to 22kW (400V). The SM1P... switches have dimensions compliant with the DIN43880 standard which allow them to be mounted in all modular enclosures on the market. They are suitable for isolation in compliance with IEC/EN 60947 standards and can be padlocked in the OFF position without using accessories. The high breaking capacity values ​​allow, in most installations, to avoid the use of fuses.

    €52,90

  • 21109 | Schneider Electric

    SCHNEIDER ELECTRIC 21109 | Schneider Electric

    Schneider Electric 21109P25M motor protection switches, ensure protection of single-phase or three-phase motors and local manual control. This protection device ensures: isolation, manual control or remote control, protection against short circuits (magnetic) and protection against overloads (thermal). • Complies with CEI EN 60947-2 and CEI EN 60947-1 standards (association with contactors) • Certifications: CEBEC, DEMKO, NEMKO, SEMKO, FI • Rated voltage (Ue): 690 V AC • Insulation voltage (Ui): 690 V • Impulse withstand voltage (Uimp): 6 kV • Sensitive to phase failure • Breaking capacity according to CEI EN 60947-2 [kA]

    €125,75

  • 21107 | Schneider Electric

    SCHNEIDER ELECTRIC 21107 | Schneider Electric

    Schneider Electric 21107P25M motor protection switches, ensure protection of single-phase or three-phase motors and local manual control. This protection device ensures: isolation, manual control or remote control, protection against short circuits (magnetic) and protection against overloads (thermal). • Complies with CEI EN 60947-2 and CEI EN 60947-1 standards (association with contactors) • Certifications: CEBEC, DEMKO, NEMKO, SEMKO, FI • Rated voltage (Ue): 690 V AC • Insulation voltage (Ui): 690 V • Impulse withstand voltage (Uimp): 6 kV • Sensitive to phase failure • Breaking capacity according to CEI EN 60947-2 [kA]

    €101,25

  • 21108 | Schneider Electric

    SCHNEIDER ELECTRIC 21108 | Schneider Electric

    Schneider Electric 21108P25M motor protection switches, ensure protection of single-phase or three-phase motors and local manual control. This protection device ensures: isolation, manual control or remote control, protection against short circuits (magnetic) and protection against overloads (thermal). • Complies with CEI EN 60947-2 and CEI EN 60947-1 standards (association with contactors) • Certifications: CEBEC, DEMKO, NEMKO, SEMKO, FI • Rated voltage (Ue): 690 V AC • Insulation voltage (Ui): 690 V • Impulse withstand voltage (Uimp): 6 kV • Sensitive to phase failure • Breaking capacity according to CEI EN 60947-2 [kA]

    €101,25

  • 21106 | Schneider Electric

    SCHNEIDER ELECTRIC 21106 | Schneider Electric

    Schneider Electric 21106P25M motor protection switches, ensure protection of single-phase or three-phase motors and local manual control. This protection device ensures: isolation, manual control or remote control, protection against short circuits (magnetic) and protection against overloads (thermal). • Complies with CEI EN 60947-2 and CEI EN 60947-1 standards (association with contactors) • Certifications: CEBEC, DEMKO, NEMKO, SEMKO, FI • Rated voltage (Ue): 690 V AC • Insulation voltage (Ui): 690 V • Impulse withstand voltage (Uimp): 6 kV • Sensitive to phase failure • Breaking capacity according to CEI EN 60947-2 [kA]

    €101,25

  • 417307 | Legrand

    LEGRAND 417307 | Legrand

    Legrand 417307Three-phase thermal-magnetic circuit breaker with lever control - Vn=690V - Ir=2.5-4A - Im= 52A - Icu= 100kA (at 415Vac) - Pw motors 1.5W. Complies with IEC 60947-1, IEC 60947-2, IEC 60947-4 standards. Adjustable thermal release. Magnetic release calibrated at 13Iemax.

    €96,44

  • EP 882 3 | Abb

    ABB EP 882 3 | Abb

    Abb EP 882 3MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €65,66

  • 3RV20314KA10 | Siemens

    SIEMENS 3RV20314KA10 | Siemens

    Siemens 3RV20314KA10circuit breaker frame size S2 for motor protection, CLASS 10 release A 62...73 A release N 949 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €229,51

  • EP 886 4 | Abb

    ABB EP 886 4 | Abb

    Abb EP 886 4MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €81,35

  • 3RV20111CA20 | Siemens

    SIEMENS 3RV20111CA20 | Siemens

    Siemens 3RV20111CA20circuit breaker frame size S00 for motor protection, CLASS 10 release A 1.8...2.5 A release N 33 A spring terminal standard operating capacity SIRIUS circuit breaker 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized due to their low leakage thermal, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €61,44

  • 046988 | Eaton

    EATON 046988 | Eaton

    Eaton 046988Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip

    €86,73

  • 3RV20314WA15 | Siemens

    SIEMENS 3RV20314WA15 | Siemens

    Siemens 3RV20314WA15circuit breaker frame size S2 for motor protection, CLASS 10 release A 42 ... 52 A release N 741 A screw terminal standard operating capacity with front auxiliary switch block 1NO +1NC SIRIUS3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low thermal dispersion, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €219,14

  • GV2P32 | Schneider Electric

    SCHNEIDER ELECTRIC GV2P32 | Schneider Electric

    Schneider Electric GV2P32GV2P32 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 15 kW motors at 400 V and a high breaking capacity Icu 50 kA. Start-stop control via rotary handle guaranteed for 100,000 cycles AC-3 415V. GV2P32 is a TeSys GV motor circuit breaker from Schneider Electric designed for 15 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal regulation range of 24-32 A, magnetic tripping at 12 xIn and a high breaking capacity Icu 50 kA at 400 V. Start-stop control via rotary handle guaranteed for 100,000 cycles AC-3 415V. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).

    €141,15

  • EP 142 2 | Abb

    ABB EP 142 2 | Abb

    Abb EP 142 2MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €62,74

  • 21105 | Schneider Electric

    SCHNEIDER ELECTRIC 21105 | Schneider Electric

    Schneider Electric 21105P25M motor protection switches, ensure protection of single-phase or three-phase motors and local manual control. This protection device ensures: isolation, manual control or remote control, protection against short circuits (magnetic) and protection against overloads (thermal). • Complies with CEI EN 60947-2 and CEI EN 60947-1 standards (association with contactors) • Certifications: CEBEC, DEMKO, NEMKO, SEMKO, FI • Rated voltage (Ue): 690 V AC • Insulation voltage (Ui): 690 V • Impulse withstand voltage (Uimp): 6 kV • Sensitive to phase failure • Breaking capacity according to CEI EN 60947-2 [kA]

    €101,25

  • 3RV24111EA10 | Siemens

    SIEMENS 3RV24111EA10 | Siemens

    Siemens 3RV24111EA10circuit breaker size S00 for transformer protection release A 2.8...4 A release N 82 A screw terminal standard switching power SIRIUS 3RV2 circuit breaker For transformer protection for safe short-circuit and overload protection of transformers.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low thermal dispersion, for use in feeders, naturally also for IE3/IE4 motors and equally for the switching of direct current. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €70,34

  • 072733 | Eaton

    EATON 072733 | Eaton

    Eaton 072733Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip

    €61,45

  • 072734 | Eaton

    EATON 072734 | Eaton

    Eaton 072734Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip

    €66,74

© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • Amazon
    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account