SIEMENS CONTROL RELAY
-
SIEMENS 6EP19612BA41 | Siemens Sitop PSE200U 10 A
SIEMENS SITOP PSE200U 10 A 6EP19612BA41 SITOP PSE200U 10 A 4-channel selective module input: DC 24 V/40 A output: DC 24 V/4x 10 A threshold value settable 3 ... 10 A with status message for each output * Ex approval no longer available* Inputshape of the electrical network Regulated DC voltagesupply voltage with DC nominal value 24 Vinput voltage with DC 22 ... 30 Voverloadability for overvoltage 35 Vinput current at nominal value of theinput voltage 24 V nominal value 40 A Outputshape of the voltage curve at the output Regulated DC voltageformula for output voltage Ue - approx. 0.2 Vrelative overall tolerance of the known voltage Corresponding to the input supply voltagenumber of outputs 4output current up to 60 °C for each output nominal value 10 Avalue of trip settable for release current ofcurrent-dependent overload 3 ... 10 Atype of setting of the trip value Via potentiometerproduct characteristic parallel connection of outputs Notype of insertion of the outputs Simultaneous activation of all the outputs upon reaching the value ofsupply voltage regime > 20 V, delay time of 24 ms, 100ms or settable via DIP switch for sequential insertion "optimized for the load " Efficiencyefficiency [%] 99 %power dissipation [W] at nominal value of theoutput voltage at nominal value of the output current typ. 10 WDisconnection characteristic per outputswitching characteristic● of the overcurrent disconnection IA = 1.0 ... 1, 5 x set value, switches off after approx. 5 s● of the current limitation IA = 1.5 x set value, shutdown after typ. 100 ms● of immediate switch-off IA > set value and Ue residual current at switch-off typ. 1 mAReset execution via button for each outputRemote RESET function 24 V non-floating input (signal level "high" at > 15 V)Protection and monitoringcarrying out protection on the 15 A input for each output (not accessible)running the display for normal operation Tricolor LED for each output: green LED for "Output on", yellow LED for " Output switched off manually", red LED for "Output switched off due to overcurrent"design of switching contact for signaling functionStatus signal output (pulse/pause signal can be analyzed via functional moduleSIMATIC)Safetypotential separation between input and output at No
€148,60
-
SIEMENS 6EP44387FB003DX0 | Siemens Sitop SEL1200 Selectivity Module 8 *10A
SIEMENS SITOP SEL1200 SELECTIVITY MODULE 8 *10A 6EP4438-7FB00-3DX0 SITOP SEL1200 8-channel selective module switching characteristic input: DC 24 V/60 A output: DC 24 V/8 x 10 A settable threshold value 2 ... 10 A with monitoring interface. General information: Inputshape of the electrical network Regulated DC voltagesupply voltage with DC rated value 24 Vinput voltage with DC 20.4 ... 30 Voverloadability for overvoltage 35 Vinput current with nominal value of theinput voltage 24 V rated value 60 A Outputshape of the voltage curve at the output Regulated DC voltageformula for output voltage Ue - approx. 0.2 Voverall relative voltage tolerance known Corresponding to the input supply voltage number of outputs 8output current up to 60 °C for each output rated value 10 A; +60 ... +70 °C: Derating 2%/K settable trip value for current-dependent overload release current 2 ... 10 Atype of trip value setting Via potentiometerproduct characteristic parallel connection of outputs Yestype of activation of the outputs Activation of all outputs when the operating value is reached of thesupply voltage > 20 V, delay time of 25 ms, 200 ms, 500ms or adjustable via DIP switch for "load-optimized" sequential switching on Efficiencyefficiency [%] 98 %power dissipation [W] at nominal value of theoutput voltage at nominal value of the output current typ. 18 W Switch-off characteristic for each outputswitching characteristic● of overcurrent shutdown IA > 2.0 x set value, switch-off after approx. 30 ms, IA > 1.8 x setvalue, switches off after approx. 0.1 s, IA > 1.5 x set value,switch-off after approx. 1 s, IA > 1.0 x set value, switches off after approx. 5 s● of immediate switch-off IA > set value and Ue 15 V) Protection and monitoring performing protection on the 16 A input for each output (not accessible) performing the display for normal operation Tricolor LED for each output: green LED for "Output activated", yellow LED for "Output manually deactivated", red LED for "Output deactivated due to overcurrent" execution of the switching contact for signaling function. Status signal output or floating cumulative signaling contact (pause/pulse signal selectable from theSimaticfunction block).
€139,99
-
SIEMENS 6EP19612BA21 | Siemens Sitop PSE200U Selectivity Module 10A
SIEMENS SITOP PSE200U SELECTIVITY MODULE 10A 6EP19612BA21 SITOP PSE200U 10 A 4-channel selective module input: DC 24 V/40 A output: DC 24 V/4x 10 A threshold value settable 3 ... 10 A with cumulative signaling contact. General information: Inputshape of the electrical network Regulated DC voltagesupply voltage with DC nominal value 24 Vinput voltage with DC 22 ... 30 Voverloadability for overvoltage 35 Vinput current at nominal value of theinput voltage 24 V nominal value 40 A Outputshape of the voltage curve at the output Regulated DC voltageformula for output voltage Ue - approx. 0.2 Vrelative overall tolerance of the known voltage Corresponding to the input supply voltagenumber of outputs 4output current up to 60 °C for each output nominal value 10 Avalue of trip settable for release current ofcurrent-dependent overload3 ... 10 Atype of trip value setting By potentiometerproduct characteristic parallel connection of outputs No type of activation of the outputs Simultaneous activation of all the outputs upon reaching the value ofsupply voltage regime > 20 V, delay time of 24 ms, 100ms or settable via DIP switch for sequential activation"load optimized" Efficiencyefficiency [%] 99 %power dissipation [W] at nominal value of theoutput voltage at nominal value of the output current typ.10 W Switch-off characteristic for each outputswitching characteristic● of the overcurrent switch-off IA = 1.0 ... 1.5 x set value, switch-off after approx. . 5 s● of the current limitation IA = 1.5 x set value, shutdown after typ. 100 ms● of immediate switch-off IA > set value and Ue residual current at switch-off typ. 1 mAReset execution via button for each outputRemote RESET function Non-floating 24 V input (signal level "high" at > 15 V) Protection and monitoringcarrying out protection on the 15 A input for each output (not accessible)running the display for normal operation Tricolor LED for each output: green LED for "Output switched on", yellow LEDfor "Output manually switched off", red LED for "Output switched off due to overcurrent" design of switching contact for signaling functionGroup signaling contact (changeover contact, loadability 0 ,1 A/DC 24 V).
€148,60