POWER DISTRIBUTION

108 products

  • 202482300000 | Finder rele ad impulsi

    FINDER 202482300000 | Finder pulse relay 17.5MM 2NO 16A 4 sequential.

    Finder Pulse relay 17.5MM 2NO 16A 4 sequential. 202482300000 Type 20.24 modular pulse relay with bipolar switch, for direct mounting on 35 mm rail (EN 60715). Features: One module width 17.4 mm Test button and mechanical indicator 7 sequences available AC or DC coil Identification card Possibility of connection with illuminated buttons using the adapter 026.00 Cadmium-free contacts

    €24,20

  • 202182300000 | Finder 16 A modular pulse relay

    FINDER 202182300000 | Finder 16 A modular pulse relay

    Finder modular pulse relay 16 A 202182300000 Modular pulse relay, 16A, with 1 NO single-pole switch, for direct mounting on 35mm rail (EN 60715). One module width 17.4 mm, Test button and mechanical indicator, 7 sequences available, AC or DC coil. Technical description: Modular pulse relay, 35 mm rail mounting (EN 60715), 1 NO single pole switch, 16 A, AgNi, AC coil, 230 V, operation from 196 to 253 V, nominal power 6.5 VA, resistance 2500 Ω, absorption 28 mA, ambient temperature from -40 to +40 °C.

    €20,30

  • LV426708 | Schneider-electric Circuit breaker

    SCHNEIDER ELECTRIC LV426708 | Schneider-electric Circuit breaker

    Schneider-electric Compact NSXm Vigi circuit breaker 160A 4P 16kA EverLink connector  LV426708 The LV426708 is a Compact NSXm residual current circuit breaker with Micrologic Vigi 4.1 control unit, 160 A, 16 kA at 415 VAC. It is designed for all standard LV applications. It provides integrated earth leakage protection for transformer-fed distribution systems. It features new features such as Everlink connector technology. It offers plate and DIN rail mounting capabilities and externally visible spring-loaded auxiliaries. This 4-pole integrated residual current circuit breaker (ELCB) is one of the smallest on the market. Dimensions: 108 mm (W) x 144 mm (H) x 80 mm (D). It ensures compliance with international standards (IEC 60947/CCC/EACH) and marine specifications. Technical dataRangeCompactProduct NameCompact NSXmProduct rangeCompact NSXmDevice Name"NSXm 160E"Product typeDifferential circuit breakerApplicationProtectionDistributionNumber of poles4Pprotected poles description"4D"neutral positionLeftRated current [In]160 A at 40 °CRated operational voltage [Ue]440VAC 50/60HzNetwork typeCANetwork frequency50/60 HzAptitude for sectioningYes compliant with EN/IEC 60947-2Category of useCategory A[Icu] rated ultimate short-circuit breaking capacity25 kA Icu compliant with IEC 60947-2 at 220...240 V AC 50/60 Hz16 kA Icu compliant with IEC 60947-2 at 380...415 V AC 50/60 Hz10 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 HzPerformance levelAnd 16 kA 415 V ACRelease Name"Micrologic 4.1"Release technologyElectronictrip unit protection functionsLSoIRControl typeLeverCircuit breaker mounting modeWith screwsHookupRated insulation voltage [Ui]500VAC 50/60HzRated impulse withstand voltage [Uimp]8kV[Ics] rated service short-circuit breaking capacity25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA at 380...415 V AC 50/60 Hz compliant with IEC 60947-210 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2Mechanical durability20000 cyclesElectrical life10000 cycles at 440V In20000 cycles at 440 V In/2InstallationPlateDIN railConnection terminals1 Everlink connector 2.5…70 mm², flexible copper1 Everlink connector 2.5…95 mm², rigid or stranded aluminum/copperConnection step35mm with diffusers27 mm Without spacers9mm steps12 moduletype of protectionL : for overload protection (thermal)"So": for short-time short-circuit protection with fixed delayI : for Instantaneous short circuit protectionR : for earth leakage protectionRelease gauge160 A at 40 °Cthermal memory20 minutes before and after the shotdifferential protectionIntegratedEarth-leakage protection sensitivity adjustment type IΔnAdjustable[IΔn] earth-leakage protection sensitivity adjustment range0.03…5 ADifferential Sensitivity30 mA for class A100 mA for class A300 mA for class A500 mA for class A1000 mA for class A30 mA for AC class100 mA for AC class300 mA for AC class500 mA for AC class1000 mA for AC class3000 mA for AC class5000 mA for AC classEarth leakage protection delay adjustment type Δt Adjustable[Dt] Erth-loss prefix price delay adjustment interval 0 ms60 ms150 ms500 ms1000 msSecurity SettingsNo protection1 x Ir0.5 x IrNumber of slots for electrical auxiliaries1 slot for OF auxiliary contact1 SD alarm contact slot1 "MN or MX" opening coil slotlocal reportingLED flashing (green) ready for operation:LED 105% Ir (red)Overload:LED 90% Ir (orange)Overload:Length108mmHeight144mmDepth80mmProduct weight1.63 kgColorGrey (RAL 7016)

    €996,30

  • 1489M3D150 | Allen bradley UL489 15 A

    ALLEN-BRADLEY 1489M3D150 | Allen-bradley UL489 15 A miniature circuit breaker

    Allen-bradley UL489 15 A miniature circuit breaker  1489M3D150 Miniature switch, 15 A, 3 pole, 480Y/277Volt AC, type D trip curve, inductive. Technical data Recess depth: 79.38 mm Trip characteristic: D Number of poles (total): 3 Rated current: 15 A Rated voltage: 400 V Voltage type: AC Rated breaking capacity Icu according to IEC 60947-2 at 230 V: 15 kA Rated breaking capacity Icu according to IEC 60947-2 at 400 V: 15 kA Frequency: 50...60 Hz With neutral: no Overvoltage category: 3 Pollution degree: 3 Can be accessorised: yes Protection degree (IP): IP20

    €67,75

  • 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    ABB 1SDA068066R1 | Abb XT3N 250 TMD 250-2500 4p F F InN=50%

    Abb XT3N 250 TMD 250-2500 4p F F InN=50% 1SDA068066R1 Tmax XT3N 250 fixed four-pole circuit breaker with front terminals and thermomagnetic releases TMD R 250-2500 A neutral = 50% phases. Technical data  Type of switch to associate: Power Distribution Cable sections-main circuit: Busbar 85..192 mm² Current type: AC/DC Electrical life: 120 cycles per hour8000 cycle (i) Mechanical durability: 240 cycles per hour25000 cycle (i) Number of poles: 4 Opening duration: CB with SOR 15 msCB with UVR 15 ms Multiple order: 1 piece(s) Loss of power: a Nominal Operating Conditions for Polo 17.8 W Product main type: SACE Tmax XT Product name: Moulded-case switch Product type: Automatic Circuit Breaker Rated current (In): 250 A Nominal frequency (f): 50 / 60 Hz Rated voltage (Ur): 690 V Impulse withstand voltage (Uimp): 8 kV Rated instantaneous short-circuit current setting (Ii): 2500 A Rated insulation voltage (Ui): 800V Rated operating voltage: 690 V AC500 V DC  

    €952,90

  • 1SAE231111R0131 | Abb ESB25-31N-01

    ABB 1SAE231111R0131 | Abb ESB25-31N-01

    Abb ESB25-31N-01 1SAE231111R0131 Modular contactors - Automatic control - 3 n.o. contacts + 1 n.c. contact Technical data Rated operating voltage: Main Circuit 220 V DCMain Circuit 400 V AC Nominal control circuit voltage (Uc): 24V Nominal frequency (f): Control Circuit 400 HzControl Circuit 50 HzControl Circuit 60 HzDC Control CircuitMain Circuit 50 HzMain Circuit 60 HzMain Circuit DC Rated operating current AC-1 (Ie): (NC) 25 A(NO) 25 A Rated operating current AC-3 (Ie): (230 V) Single Phase, NC 6 A(230 V) Single Phase, NO 9 A(400 V) Three Phase, NO 9 A Rated operating current AC-1 (Pe): (230 V) Single Phase, NC 5.8 kW(230 V) Single Phase, NO 5.8 kW(400 V) Three Phase, NO 17.3 kW Rated operating current AC-3 (Pe): (230 V) Single Phase, NC 1.3 kW(230 V) Single Phase, NO 1.3 kW(400 V) Three Phase, NO 4 kW Rated operating current AC-7a (Ie): (NC) 25 A(NO) 25 A Rated operating current AC-7a (Pe): (230 V) Single Phase, NC 5.8 kW(230 V) Single Phase, NO 5.8 kW(400 V) Three Phase, NO 17.3 kW Rated operating current AC-7b (Ie): (230 V) Single Phase, NC 6 A(230 V) Single Phase, NO 9 A(400 V) Three Phase, NO 9 A Rated operating current AC-7b (Pe): (230 V) Single Phase, NC 0.9 kW(230 V) Single Phase, NO 1.3 kW(400 V) Three Phase, NO 4 kW Recommended screwdriver: Control Circuit Pozidriv 1Main Circuit Pozidriv 1 Impulse withstand voltage (Uimp): 6 kV Rated insulation voltage (Ui): 500V Cable sections - main circuit: Flexible with Ferrule 1x 1.5 ... 10 mm²Flexible with Ferrule 2x 1.5 ... 2.5 mm²Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²Flexible with Insulated Ferrule 2x 1.5 mm² Flexible 1x 1.5 ... 10 mm²Flexible 2x 1.5 ... 4 mm²Rigid 1x 1.5 ... 10 mm²Rigid 2x 1.5 ... 4 mm² Control circuit-cable sections: Flexible with Ferrule 1x 1 ... 2.5 mm²Flexible with Ferrule 2x 0.75 ... 1 mm²Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 . .. 1 mm²Flexible 1x 1 ... 4.0 mm²Flexible 2x 1 ... 2.5 mm²Rigid 1x 1 ... 4 mm²Rigid 2x 1 ... 2.5 mm² Tightening torque: Control Circuit 0.9 N mMain Circuit 1 N m Cable stripping length: Control Circuit 7 mmMain Circuit 10 mm Degree of protection: IP20 Electrical life: AC-1 (NC) 50000 cycle (i)AC-1 (NO) 130000 cycle (i)AC-3 (NC) 340000 cycle (i)AC-3 (NO ) 500000 cycle (i)AC-7a (NC) 50000 cycle (i)AC-7a (NO) 130000 cycle (i)AC-7b (NC) 340000 cycle (i)AC-7b (NO) 500000 cycle (i) Mechanical durability: 1000000 cycle (i) Number of poles: 4 Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of NC main contacts: 1 Number of main NA contacts: 3 Width in number of modular intervals: 2 Pollution degree: 3 Reference standards: IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 61095UL 60947-1UL 60947-4-1 UL/CSA Technical Department Maximum operating voltage UL/CSA: Main Circuit 480 V AC UL/CSA Scope: (220 ... 240 V AC) Single Phase, NC 1 Hp(220 ... 240 V AC) Single Phase, NO 1 Hp(220 ... 240 V AC) Three Phases, NO 3 Hp(440 ... 480 V AC) Single Phase, NC 2 Hp(440 ... 480 V AC) Single Phase, NO 2 Hp(440 ... 480 V AC) Three Phases , NO 5 Hp UL/CSA main circuit cable cross sections: Solid 16-8 AWGStranded 16-8 AWG UL/CSA control circuit cable cross sections: Solid 16-10 AWGStranded 16-10 AWG UL/CSA tightening torque: Control Circuit 8 in lbMain Circuit 9 in lb

    €44,40

  • 2CSM228735R0802 | Abb TM15/12

    ABB 2CSM228735R0802 | Abb TM15/12

    Abb TM15/12 2CSM228735R0802 Failure-proof doorbell transformers. Voltage: primary 230 V AC - secondary 4-8-12 V a.c. SELV or 12-24 V AC SELV. Technical data Reference standards: IEC/EN 61558-2-8 Application: Residential Primary voltage: 230V Secondary voltage: (6-7) 4 V AC(5-6) 8 V AC(5-7) 12 V AC Secondary current: 1.25 A Maximum output current (Iout): 3.75 A Nominal frequency (f): 50/60 Hz Loss of power: 2.5 W Power: 15 V·A Rated output power: 15 W Insulation class: B Tightening torque: 0.5 N·m

    €18,45

  • 2CDS200912R0001 | Abb S2C-H6R

    ABB 2CDS200912R0001 | Abb S2C-H6R

    Abb S2C-H6R 2CDS200912R0001 Order Code: A563826 - Auxiliary contact. allows the indication of the position of the device contacts. Suitable for MCB S 200 series, SN 201 series (via the SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical data Reference standards: CSA Class 3215-30CSA Class 3215-90GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function: Auxiliary contact Suitable for: S200S200MS200PS200SS300PSN201L+SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Suitable for product class: Miniature Circuit BreakerResidual Current Device Loss of power: 0.5 WMaximum 0.5 W Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of auxiliary contacts c/o (SPDT): 1 Accessory type: Auxiliary contact Mounting position: right Technical information: AUXILIARYCONTACT

    €20,60

  • 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    ABB 2CSB204001R3630 | Abb DDA204 AC-63/0.3

    Abb DDA204 AC-63/0.3 2CSB204001R3630 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type AC Rated voltage (Ur): 230/400 V Rated operating voltage: 230/400 V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 300 mA Leakage Current Type: AC Nominal frequency (f): 50 … 60 Hz Loss of power: 7.6 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 4 Operational characteristic: Instant Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²

    €112,95

  • 1sda066325r1 - ABB

    ABB 1SDA066325R1 | ABB SOR-C XT1..XT4 F/P. Wired opening release

    Abb SOR-C XT1..XT4 F/P 1SDA066325R1 WIRED OPENING RELEASE 220-240V AC-220-250V DC FOR FIXED-REMOVABLE XT1..XT4 Additional information Configuration type: Loose or Configurable Current type: AC/DC Multiple order: 1 piece(s) Product main type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Rated voltage (Ur): 220 ... 240 V AC220 ... 250 V DC Reference standards: IECUL Suitable for: XT1, XT2, XT3, XT4 Suitable for product class: SACE Tmax XT

    €90,30

  • 2CMA100164R1000 | Abb B23 112-100

    ABB 2CMA100164R1000 | Abb B23 112-100

    Abb B23 112-100 2CMA100164R1000 Order Code: B231121 - The B series EQ Meters are characterized by their compactness and are the ideal solution for 230 V AC systems. both single-phase and three-phase. They allow you to view, depending on the version chosen, the following quantities: active, reactive, apparent energy; active, reactive, apparent power; currents; frequency; tensions; division of consumption into tariffs; power factor; bidirectional consumption. All codes are certified according to the MID directive, are equipped with outputs for managing pulses or alarms, and an infrared port for communication with KNX adapter. Depending on the version, the meters are equipped with integrated serial communication interfaces for Modbus RTU (RS485 version) and Meter BUS (M-Bus versions) Technical data Reference standards: EN 50470-1 Function: Electricity meter Subfunction: Steel Rated voltage (Ur): 3x220-240 V Voltage range: 3x176…276 V Rated current (In): 5 AMaximum 65 A Rated current: 5 A Nominal frequency (f): 50 / 60 Hz Power consumption (@Pcons): 0.721 W Communication interface: Modbus RS485 Accuracy: Active Energy Cl. ±1% (or B for MID meters) Measuring Instrument Conformity: Measurement Instrument Directive (MID) Meter Tariff Rating: One-Tariff Pulse Output Rate: 1-999999 Number of poles: 4 Number of phases: Three-phase Number of Counter Positions: 7 Number of digital inputs/outputs: 1 C Type of measurement: Direct connection Mounting type: DIN rail Pulse Output Type: Electrical Type of Indicator: Digital Container material: Plastic I/O option: 1 digital output Communication: Modbus RTU Cable sections-main circuit: 1 ... 25 mm²

    €241,80

  • 2CSB202701R1630 | Abb DDA202 A-63/0.03 AE

    ABB 2CSB202701R1630 | Abb DDA202 A-63/0.03 AE

    Abb DDA202 A-63/0.03 AE 2CSB202701R1630 Order Code: B428017 - The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. G Type of residual current: Type A Application: For emergency stop Rated voltage (Ur): 230/400 V Rated operating voltage: 230V Rated insulation voltage (Ui): 500 V Impulse withstand voltage (Uimp): 4 kV Rated current (In): 63 A Rated residual current: 30 mA Leakage Current Type: A Nominal frequency (f): 50 … 60 Hz Loss of power: 5 W Supply voltage connection: Arbitrary Electrical resistance: 10000 cycle (i) Number of poles: 2 Operational characteristic: Instantaneous (AE for Emergency Stop) Provided options: For emergency stop Connection capacity: Rigid 25 ... 25 mm²Flexible 25 ... 25 mm²  

    €188,05

  • 2CDS242701R0164 | Abb S202L-C16

    ABB 2CDS242701R0164 | Abb S202L-C16

    Abb S202L-C16 2CDS242701R0164 The System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200 series differential blocks. Technical data Reference standards: IEC/EN 60898-1IEC/EN 60947-2 Trip characteristic: C Rated operating voltage: according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 400 V AC Operating voltage: Maximum (Incl. Tolerance) 440 V ACMinimum 12 V AC Rated insulation voltage (Ui): according to IEC/EN 60664-1 440 V Impulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kV Dielectric test voltage: 50/60 Hz, 1 min: 2 kV Input voltage type: AC Rated current (In): 16 A Short-circuit rating: (AC) 4.5 kA(DC) 4.5 kA(400 V AC) 4.5 kA(400 V) 4.5 kA Rated extreme short-circuit capacity (Icu): (230 V AC) 10 kA(400 V AC) 6 kA(230 V) 10 kA(400 V) 6 kA Rated conditional short-circuit current (Inc): (400 V) 6 kA Rated service short-circuit capacity (Ics): (230 V AC) 7.5 kA(400 V AC) 4.5 kA Nominal frequency (f): 50 / 60 Hz50 ... 60 Hz Loss of power: 5 Wa Nominal Operating Conditions for Polo 2.5 W Supply voltage connection: Arbitrary Contact position indication: ON / OFF

    €9,50

  • 1SDA067130R1 | Abb RC Sel HV 85...690Vac XT3 4p F

    ABB 1SDA067130R1 | Abb RC Sel HV 85...690Vac XT3 4p F

    Abb RC Sel HV 85...690Vac XT3 4p F 1SDA067130R1 RC sel HV 85...690V AC residual current release for XT3 four-pole fixed inter. Configuration type: Loose or Configurable Number of poles: 4 Multiple order: 1 piece(s) Main product type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Reference standards: IEC Suitable for: XT3 Suitable for product class: SACE Tmax XT  

    €706,60

  • 1SAE341111R0131 | Abb ESB40-31N-01

    ABB 1SAE341111R0131 | Abb ESB40-31N-01

    Abb ESB40-31N-01 1SAE341111R0131 Technical data Rated operating voltage: Main Circuit 220 V DCMain Circuit 400 V AC Nominal control circuit voltage (Uc): 24V Nominal frequency (f): Control Circuit 400 HzControl Circuit 50 HzControl Circuit 60 HzDC Control CircuitMain Circuit 50 HzMain Circuit 60 HzMain Circuit DC Rated operating current AC-1 (Ie): (NC) 30 A(NO) 40 A Rated operating current AC-3 (Ie): (230 V) Single Phase, NO 22 A(400 V) Three Phase, NO 22 A Rated operating current AC-1 (Pe): (230 V) Single Phase, NC 6.9 kW(230 V) Single Phase, NO 9.2 kW(400 V) Three Phase, NO 27.7 kW Rated operating current AC-3 (Pe): (230 V) Single Phase, NO 3.7 kW(400 V) Three Phase, NO 11 kW Rated operating current AC-7a (Ie): (NO) 40 A Rated operating current AC-7a (Pe): (230 V) Single Phase, NC 6.9 kW(230 V) Single Phase, NO 9.2 kW(400 V) Three Phase, NO 27.7 kW Rated operating current AC-7b (Ie): (230 V) Single Phase, NO 22 A(400 V) Three Phase, NO 22 A Rated operating current AC-7b (Pe): (230 V) Single Phase, NO 3.7 kW(400 V) Three Phase, NO 11 kW Recommended screwdriver: Control Circuit Pozidriv 1Main Circuit Pozidriv 2 Impulse withstand voltage (Uimp): 6 kV Rated insulation voltage (Ui): 500V Cable sections-main circuit: Flexible with Ferrule 1x 1.5 ... 16 mm²Flexible with Ferrule 2x 1.5 ... 10 mm²Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²Flexible with Insulated Ferrule 2x 1.5 . .. 10 mm²Flexible 1x 1.5 ... 16 mm²Flexible 2x 1.5 ... 10 mm²Rigid 1x 1.5 ... 25 mm²Rigid 2x 1.5 ... 10 mm² Control circuit-cable sections: Flexible with Ferrule 1x 0.75 ... 2.5 mm²Flexible with Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 . .. 1 mm²Flexible 1x 1 ... 4.0 mm²Flexible 2x 1 ... 2.5 mm²Rigid 1x 1 ... 4 mm²Rigid 2x 1 ... 2.5 mm² Tightening torque: Control Circuit 0.9 N·mMain Circuit 2.5 N m Cable stripping length: Control Circuit 7 mmMain Circuit 13 mm Degree of protection: IP20 Electrical life: AC-1 (NC) 70000 cycle (i)AC-1 (NO) 150000 cycle (i)AC-3 (NO) 100000 cycle (i)AC-7a (NC ) 70000 cycle (i)AC-7a (NO) 150000 cycle (i)AC-7b (NO) 100000 cycle (i) Mechanical durability: 1000000 cycle (i) Number of poles: 4 Number of NC auxiliary contacts: 0 Number of auxiliary contacts NO: 0 Number of NC main contacts: 1 Number of main NA contacts: 3 Width in number of modular intervals: 3 Pollution degree: 3 Reference standards: IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 61095UL 60947-1UL 60947-4-1

    €100,55

  • 2CSB204101R1400 | Abb DDA204 A-40/0.03

    ABB 2CSB204101R1400 | Abb DDA204 A-40/0.03

    Abb DDA204 A-40/0.03 2CSB204101R1400 The DDA 200 differential blocks can be coupled to the thermal-magnetic circuit breakers of the S 200 L, S 200, S 200 M, S 200 P series to achieve the thermal-magnetic differential protection function. It is possible to couple the DDA 200 with the magnetic-only switches of the M 200 series, in this case for protection against overload currents it is necessary to provide additional thermal protection. Technical data Reference standards: IEC/EN 61009 Ann. GType of residual current: Type A Rated voltage (Ur): 230/400 VRated operating voltage: 230/400 VRated insulation voltage (Ui): 500 VImpulse withstand voltage ( Uimp): 4 kV Rated current (In): 40 ARated residual current: 30 mALeakage Current Type: ARated frequency (f): 50 … 60 Hz Power loss: 4.8 WSupply voltage connection: ArbitraryElectrical resistance: 10000 cycle(s) Number of poles: 4Operational characteristic: InstantaneousConnection capacity: Rigid 16 ... 16 mm²Flexible 16 ... 16 mm²

    €179,80

  • 1SDA067121R1 | Abb RC Sel 200 HV 85...690Vac XT1 4p F

    ABB 1SDA067121R1 | Abb RC Sel 200 HV 85...690Vac XT1 4p F

    Abb RC Sel 200 HV 85...690Vac XT1 4p F 1SDA067121R1 RC SEL 200 low residual current release for MOD.200mm HV 85...690V AC for inter. fixed four-pole XT1. Technical data Configuration type: Loose or Configurable Number of poles: 4 Multiple order: 1 piece(s) Product main type: Accessories for Tmax XT Product name: Accessory for switch Product type: Accessory Reference standards: IEC Suitable for: XT1 Suitable for product class: SACE Tmax XT  

    €527,00

  • 2CSJ201001R0002 | Abb RD3

    ABB 2CSJ201001R0002 | Abb RD3

    Abb RD3 2CSJ201001R0002  The differential relays with external toroidal transformer allow protection against earth faults. Using the minidip it is possible to adjust the sensitivity and the intervention time. Technical data Reference standards IEC EN 60947-2 Ann MType of residual current Type AFunction For mixed system Rated voltage (Ur) 400...400 VRated operating voltage 230 ... 400 V ACVoltage nominal control power supply (Us) (50 Hz) 400...400 V(60 Hz) 400...400 V Rated current Response value amperage 1 500 ... 500 mARated frequency (f) 50 … 60 HzLoss of power 3.6 W Number of contacts 2Number of c/o contacts 1Number of NC contacts 0Number of NO contacts 0Delay time (τ) Delay-On Energization, Maximum, Permitted 10 second [time unit]Delay-On Energization, Minimum, Adjustable 0 second [time unit]Mounting type DIN railFilter option no frequency filter Options provided Pre-alarm threshold: no

    €197,05

  • 4016779649728 | Abb S2C-A2L

    ABB 4016779649728 | Abb S2C-A2L

    A2L TRIP COIL 110-415V AC 4016779649728 The shunt coil is used to cause the remote opening of the switch to which it is associated by applying voltage. Technical dataFunction:Shunt TripPower loss:0 WEnvironmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019RoHS information:2CDK400627D2701REACH Declaration:9AKK107492A1906SCIP:4906475e-2b37-45cb-918c-db295dd155a2 Germany (DE)Conflict Minerals Reporting Template (CMRT) :9AKK108468A3363 DimensionsProduct width:17.5 mmProduct height:69 mmProduct depth:85 mmProduct net weight:0.14 kg

    €30,00

  • 1SDA066820R1 | Abb XT1B 160 TMD 160-1600 4p F F InN=50%

    ABB 1SDA066820R1 | Abb XT1B 160 TMD 160-1600 4p F F InN=50%

    Abb XT1B 160 TMD 160-1600 4p F F InN=50% 1SDA066820R1 TMAX XT1B 160 fixed four-pole circuit breaker with front terminals and TMD R 160-1600 thermomagnetic releases with neutral = 50% phases. Type of switch to be associated Power DistributionCable sections - main circuit Busbar 45.5 ... 80 mm²Type of current AC/DC Electrical life 120 cycles per hour8000 cycle (i)Mechanical life 240 cycles per hour25000 cycle (i) Number of poles 4Opening time CB with SOR 15 msCB with UVR 15 ms Multiple order 1 piece(s)Power loss at Nominal Operating Conditions for Polo 15 WMain product type SACE Tmax XTProduct name Molded case circuit breakerProduct type Automatic Circuit Breaker Rated current (In) 160 ARated frequency (f) 50 / 60 Hz Rated voltage (Ur) 690 VImpulse withstand voltage (Uimp) 8 kVRated instantaneous short-circuit current setting (Ii) 1600 ARated insulation voltage (Ui) 800 VRated operating voltage 690 V AC500 V DC

    €513,40

  • 2CSF202001R4250 | Abb F202 AC-25/0.5

    ABB 2CSF202001R4250 | Abb F202 AC-25/0.5

    Abb 500MA switch. differenti. pure 2CSF202001R4250 Pure RCDs without thermal-magnetic releases are switches that guarantee the protection of people from indirect contact. Technical data: Reference standards:IEC/EN 61008UL 1053Type of residual current:AC typeRated voltage (Ur):230 VRated operating voltage :230 VRated insulation voltage (Ui):500 VImpulse withstand voltage (Uimp):4 kVRated current (In):25 ARated residual current:500 mA Rated conditional short-circuit current (Inc):10 kARated service short-circuit capacity (Ics):1 kAMaximum Surge Current:0.25 kALeakage Current Type:ACFrequency nominal (f):50 … 60 HzPower loss:a Nominal Operating Conditions per Pole 1 WSupply voltage connection:ArbitraryElectrical resistance:10000 cycle (i)Number of poles :2Operating characteristic:Instant Mounting type: DIN-RailOptions Provided:NoneAccessories Available:YesConnection Capability:Busbar 10 mm²Rigid 25 ... 25 mm²Flexible 25 ... . 55 °CAmbient temperature:In operation -25...55 °CDegree of protection:IP2XDegree of pollution:2Vibration resistance according to IEC 60068-2-6:0.1 mm or 1 g - 20 cycles at 5…150…5 HzShock resistance according to IEC 60068-2-27:25g 2 shocks 13 ms

    €78,60

  • 2CDS200922R0001 | Abb S2C-S/H6R

    ABB 2CDS200922R0001 | Abb S2C-S/H6R

    Abb Signaling/auxiliary contact 2CDS200922R0001 Signaling/auxiliary contact. Suitable for MCB S 200 series, SN 201 series (via SN201-IH interface module), F 200 series RCCB, RCBO DS201 series, DS202C, DS 200 series. Technical dataReference standards: CSA 22.2 No. 235GB/T 14048.5IEC/EN 60947-5-1UL 1077 Function:Auxiliary / signaling contactSuitable for:S200S200MS200PS200SS300PSN201L+ SN201-IHSN201+SN201-IHSN201M+SN201-IHF200DS201DS202CDS200S-ARC1DS-ARC1 Maximum 0.5 WNumber of auxiliary contacts NC:0Number of auxiliary contacts NO:0Number of auxiliary contacts c/o (SPDT):1Mounting position:right Environmental dataRoHS Declaration:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Information RoHS:9AKK108468A4564REACH Declaration:9AKK107492A1906SCIP:c151f68f-6fbb-44f7-badf-ba96efd56de4 Germany (DE)Conflict Minerals Reporting Template (CMRT):9AKK108468A3363 DimensionsProduct width:8.8 mmProduct height:85 mmProduct depth:69 mmProduct net weight:0.043 kg

    €14,15

  • 2CSM204703R1801 | Abb E 92/32 PV

    ABB 2CSM204703R1801 | Abb E 92/32 PV

    Abb E 92/32 PV 2CSM204703R1801  Designed for the protection and isolation of direct current circuits of photovoltaic systems up to 1000 V dc.Usage category DC-20B. Technical dataReference standards IEC 60947-3UL 4248-19 Rated voltage (Ur): 1000 VRated operating voltage: DC-20B 1000 V DCRated insulation voltage (Ui): 1 kVRated current ( In): 32 APower loss at Nominal Operating Conditions for Pole 3 WNumber of protected poles: 2Number of poles: 2Tightening torque: 2-2.5 N·m Usage category: DC-20BFuse type: gPVLock Type: Padlockable Mounting type: DIN-RailSeal type: Sealing Wire Material of Conductor: CopperOptions Provided: NoRecommended Screwdriver: Pozidriv 2

    €5,10

  • 2CDS274001R0105 | Abb S204M-B10

    ABB 2CDS274001R0105 | Abb S204M-B10

    Abb S204M-B10 S 204 M - B10 - 10kA Curve B 10A - 4P - B - 10 A 2CDS274001R0105 System pro M compact S200 circuit breakers protect installations from overloads and short circuits, ensuring reliability and safety in operations. They are available in different characteristics (B, C, D, K, Z), configurations (1P, 2P, 3P, 4P), breaking capacity (up to 25 kA at 230/400 V AC) and rated currents (up to 100 TO). All circuit breakers in the S200 range comply with CEI-EN 60898-1, CEI-EN 60947-2 and UL1077 and CSA 22.2 No. 235 standards (except the 4.5kA version), allowing use for residential, commercial applications and industrial. Can be associated with DDA 200. series differential blocks Technical dataReference standards: IEC/EN 60898-1CSA 22.2 No. 235IEC/EN 60947-2UL 1077Tripping characteristic:BRated operating voltage: according to IEC 60898-1 400 V ACaccording to IEC 60898-1 400 Vaccording to IEC 60947-2 440 V AC Operating voltage: Maximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DCRated insulation voltage (Ui): according to IEC/ EN 60664-1 440 VImpulse withstand voltage (Uimp): 4 kVat 2000 m 5 kVat Sea Level 6.2 kVDielectric test voltage: 50/60 Hz , 1 min: 2 kVType of input voltage: AC/DCRated current (In) 10 ARated short-circuit capacity: (AC) 10 kA(230 V AC) 10 kA(400 V AC) 10 kA(400 V) 10 kARated extreme short-circuit capacity (Icu): (230 V AC) 25 kA(400 V AC) 15 kA(440 V AC) 15 kA(230 V) 25 kA(400 V) 15 kARated conditional short-circuit current (Inc ): (230 V) 15 kA(400 V) 25 kA Rated service short-circuit capacity (Ics): (230 V AC) 7.5 kAFrequency (f): 50 HzRated frequency (f): 50 / 60 Hz50 ... 60 HzPower loss: 8.4 Wat Nominal Operating Conditions for Polo 2.1 W

    €121,05

© 2024 DMSTECHMART, Powered by Shopify

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa