FREE SHIPPING throughout Europe

LC1D32D7 | Schneider Electric

Description

Schneider Electric LC1D32D7

TeSys LC1D contactor, 3 poles, AC3 440V 32A, 42 V AC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 32 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 15 kW at 380...400 V AC 50/60 Hz AC-3, 18.5 kW at 500 V AC 50/60 Hz AC-3, 18.5 kW at 660...690 V AC 50/60 Hz AC-3, 7.5 kW at 220...230 V AC50/60 Hz AC-3 - motor power in hp: 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 2 hp at 115 VAC 50/60 Hz for 1 phase motors, 20 hp at 460/480 VAC 50/60 Hz for 3 phase motors, 30 hp at 575/600 VAC 50/60 Hz for 3 phase motors, 5 hp at 230/240 V AC 50/60Hz for 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Conventional open air thermal current [Ith]: 10 A at <= 60 °C for signaling circuit, 50 A at <= 60 °C for power circuit - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947 -Rated short-time withstand current [Icw]: 100 A 1 s circuit signaling, 120 A 500 ms signaling circuit, 138 A <= 40 °C 1 min power circuit, 140 A 100 ms signaling circuit, 260 A <= 40 °C 10 s power circuit, 430 A <= 40 °C 1 s power circuit, 60 A <= 40 °C 10 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V type 2 coordination for power circuit - Rated insulation voltage [Ui]: 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V per circuit signaling CSA certifications, 600 V for signaling circuit UL certifications, 690 V for power circuit compliant with IEC 60947-4-1, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 1.4 Mcycles 50 A AC- 1 at Ue <= 440 V, 1.65 Mcycles 32 A AC-3 at Ue <= 440 V - power dissipation per pole: 2 W AC-3, 5 W AC-1 - protective cover: with - mounting support : guide, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit: screw fixing terminals 1 cables 1...4 mm² - cable rigidity: flexible - with cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable stiffness : solid - without cable end, control circuit: screw fixing terminals 2 cables 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit: screw fixing terminals 2 cables 1.. .4 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 2 cables 1...4 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cables 1.5...10 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cables 1...10 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit: screw fixing terminals 2 cables 1.5...6 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 2 cables 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit power: screw terminals 2 cables 2.5...10 mm² - cable stiffness: solid - without cable end - tightening torque: control circuit: 1.7 Nm - on screw terminals - with Philips screwdriver No 2, control circuit: 1.7 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm, power circuit: 2.5 Nm - on screw fixing terminals - with Philips screwdriver No 2, control circuit power: 2.5 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm - operating time: 12...22 ms closing, 4...19 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 15 Mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performances, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

Product form

Schneider Electric LC1D32D7TeSys LC1D contactor, 3 poles, AC3 440V 32A, 42 V AC. range: TeSys - product name: TeSys D... Read more

SKU: LC1D32D7
Barcode: 3389110350159

IT €151,78
€124,41 Excl. VAT

  •  Su ordinazione - Consegna in 3 settimane
  • STANDARD RETURN
  • QUICK DELIVERY ASSURED
  • HS CODE: 85364900
Icon for verifiedDOCUMENTATION

Documentation not available

Description

Schneider Electric LC1D32D7

TeSys LC1D contactor, 3 poles, AC3 440V 32A, 42 V AC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 32 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 15 kW at 380...400 V AC 50/60 Hz AC-3, 18.5 kW at 500 V AC 50/60 Hz AC-3, 18.5 kW at 660...690 V AC 50/60 Hz AC-3, 7.5 kW at 220...230 V AC50/60 Hz AC-3 - motor power in hp: 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 2 hp at 115 VAC 50/60 Hz for 1 phase motors, 20 hp at 460/480 VAC 50/60 Hz for 3 phase motors, 30 hp at 575/600 VAC 50/60 Hz for 3 phase motors, 5 hp at 230/240 V AC 50/60Hz for 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Conventional open air thermal current [Ith]: 10 A at <= 60 °C for signaling circuit, 50 A at <= 60 °C for power circuit - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947 -Rated short-time withstand current [Icw]: 100 A 1 s circuit signaling, 120 A 500 ms signaling circuit, 138 A <= 40 °C 1 min power circuit, 140 A 100 ms signaling circuit, 260 A <= 40 °C 10 s power circuit, 430 A <= 40 °C 1 s power circuit, 60 A <= 40 °C 10 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V type 2 coordination for power circuit - Rated insulation voltage [Ui]: 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V per circuit signaling CSA certifications, 600 V for signaling circuit UL certifications, 690 V for power circuit compliant with IEC 60947-4-1, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 1.4 Mcycles 50 A AC- 1 at Ue <= 440 V, 1.65 Mcycles 32 A AC-3 at Ue <= 440 V - power dissipation per pole: 2 W AC-3, 5 W AC-1 - protective cover: with - mounting support : guide, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit: screw fixing terminals 1 cables 1...4 mm² - cable rigidity: flexible - with cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable stiffness : solid - without cable end, control circuit: screw fixing terminals 2 cables 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit: screw fixing terminals 2 cables 1.. .4 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 2 cables 1...4 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cables 1.5...10 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cables 1...10 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit: screw fixing terminals 2 cables 1.5...6 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 2 cables 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit power: screw terminals 2 cables 2.5...10 mm² - cable stiffness: solid - without cable end - tightening torque: control circuit: 1.7 Nm - on screw terminals - with Philips screwdriver No 2, control circuit: 1.7 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm, power circuit: 2.5 Nm - on screw fixing terminals - with Philips screwdriver No 2, control circuit power: 2.5 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm - operating time: 12...22 ms closing, 4...19 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 15 Mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performances, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

  • Warranty

    Warranty

    12 month warranty. For more information visit Termini e Condizioni

  • Return Policy

    Return Policy

    Standard. For more information visit Terms and Conditions

  • E-mail

    E-mail

    Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

  • <tc>Telephone</tc>

    Telephone

    We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

Recently viewed products

© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.