LC1D256BLS207 | Schneider Electric

Description

Schneider Electric LC1D256BLS207

TeSys LC1D 25A 24 vdc ba contactor, eyelet cable lugs, for railway. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW : 11 kW at 380...400 V AC 50 Hz, 11 kW at 415 V AC 50 Hz, 11 kW at 440 V AC 50 Hz, 15 kW at 500 V AC 50 Hz, 15 kW at 660...690 V AC 50 Hz, 5.5 kW at 220...230 V AC 50 Hz - motor power in hp: 15 hp at 460/480 V AC 60 Hz for 3 phase motors, 2 hp at 115 V AC 60 Hz for 1 phase motors, 20 hp at 575/600 V AC 60 Hz for 3 phase motors, 3 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hpa 200/208 V AC 60 Hz for 3 phase motors, 7, 5 hp at 230/240 V AC 60 Hz for 3 phase motors - coil type: low absorption - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Conventional open air thermal current [Ith]: 10 A at <= 60 °C for signaling circuit, 40 A at <= 60 °C for power circuit - nominal making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 - Rated short-time withstand current [Icw]: 100 A 1 s signaling circuit, 120 A <= 40 °C 1 min circuit power circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 240 A <= 40 °C 10 s power circuit, 380 A <= 40 °C 1 s power circuit, 50 A <= 40 °C 10 min power circuit - rating of associated fuse: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 40 A gG at <= 690 V coordination type 2 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 690 V for power circuit compliant with IEC 60947-4-1, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 1.4 Mcycles 40 A AC-1 at Ue <= 440 V, 1.65 Mcycles 25 A AC-3 at Ue <= 440 V - power dissipation per pole: 1.25 W AC-3, 3.2 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 60947-4-1, DIN 5510-2, EN45545 R22 HL3, EN 45545 R26 HL3, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1 - product certifications: CCC, CSA, EAC, IEC, UL - connections - terminals: control circuit: nut connection terminals - external diameter: 8 mm, circuit power: nut connection terminals - external diameter: 12 mm - tightening torque: control circuit: 1.7 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, control circuit: 1.7 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M3.5, power circuit: 2.5 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M4, circuit power: 2.5 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M4 - operating time: 16...32 ms opening, 55...75 ms closing - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring.In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

Product form

SKU: LC1D256BLS207
Barcode: 3389118234499

€123,50

  •  Su ordinazione - Consegna in 3 settimane
  • STANDARD RETURN
  • QUICK DELIVERY ASSURED
  • HS CODE: 85364900
  DOCUMENTATION

Documentation not available

Description

Schneider Electric LC1D256BLS207

TeSys LC1D 25A 24 vdc ba contactor, eyelet cable lugs, for railway. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW : 11 kW at 380...400 V AC 50 Hz, 11 kW at 415 V AC 50 Hz, 11 kW at 440 V AC 50 Hz, 15 kW at 500 V AC 50 Hz, 15 kW at 660...690 V AC 50 Hz, 5.5 kW at 220...230 V AC 50 Hz - motor power in hp: 15 hp at 460/480 V AC 60 Hz for 3 phase motors, 2 hp at 115 V AC 60 Hz for 1 phase motors, 20 hp at 575/600 V AC 60 Hz for 3 phase motors, 3 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hpa 200/208 V AC 60 Hz for 3 phase motors, 7, 5 hp at 230/240 V AC 60 Hz for 3 phase motors - coil type: low absorption - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Conventional open air thermal current [Ith]: 10 A at <= 60 °C for signaling circuit, 40 A at <= 60 °C for power circuit - nominal making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 - Rated short-time withstand current [Icw]: 100 A 1 s signaling circuit, 120 A <= 40 °C 1 min circuit power circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 240 A <= 40 °C 10 s power circuit, 380 A <= 40 °C 1 s power circuit, 50 A <= 40 °C 10 min power circuit - rating of associated fuse: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 40 A gG at <= 690 V coordination type 2 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 690 V for power circuit compliant with IEC 60947-4-1, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 1.4 Mcycles 40 A AC-1 at Ue <= 440 V, 1.65 Mcycles 25 A AC-3 at Ue <= 440 V - power dissipation per pole: 1.25 W AC-3, 3.2 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 60947-4-1, DIN 5510-2, EN45545 R22 HL3, EN 45545 R26 HL3, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1 - product certifications: CCC, CSA, EAC, IEC, UL - connections - terminals: control circuit: nut connection terminals - external diameter: 8 mm, circuit power: nut connection terminals - external diameter: 12 mm - tightening torque: control circuit: 1.7 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, control circuit: 1.7 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M3.5, power circuit: 2.5 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M4, circuit power: 2.5 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M4 - operating time: 16...32 ms opening, 55...75 ms closing - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring.In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

  • Warranty

    12 month warranty. For more information visit Termini e Condizioni

  • Return Policy

    Standard. For more information visit Terms and Conditions

  • E-mail

    Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

  • Telephone

    We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

Recently viewed products

© 2024 DMS S.R.L. VAT IT04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account