FREE SHIPPING throughout Europe

ENGINE SAVER

166 products


  • 3RV20110EA10 | Siemens

    SIEMENS 3RV20110EA10 | Siemens

    Siemens 3RV20110EA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 0.28...0.4 A release N 5.2 A screw terminal standard operating capacity Circuit-breaker automatic SIRIUS 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized thanks to their low heat dispersion, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €69,33

  • GV2ME32 | Schneider Electric

    SCHNEIDER ELECTRIC GV2ME32 | Schneider Electric

    Schneider Electric GV2ME32GV2ME32 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 15 kW motors at 400 V and a breaking capacity Icu of 10 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME32 is a TeSys GV motor circuit breaker from Schneider Electric designed for 15 kW motorized applications at 400 V. It offers thermal magnetic protection with a 24-32 A thermal setting range, 12 xIn magnetic trip and 10 kA Icu breaking capacity at 400 V. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).

    €88,89

  • 072736 | Eaton

    EATON 072736 | Eaton

    Eaton 072736Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip

    €69,13

  • 3RV20214PA15 | Siemens

    SIEMENS 3RV20214PA15 | Siemens

    Siemens 3RV20214PA15circuit breaker frame size S0 for motor protection, CLASS 10 release A 30...36 A release N 432 A screw terminal standard operating capacity with front auxiliary contact block 1NO +1NC SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low heat dispersion, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in areas at risk of explosion (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €158,34

  • 3RV20314RA10 | Siemens

    SIEMENS 3RV20314RA10 | Siemens

    Siemens 3RV20314RA10circuit breaker frame size S2 for motor protection, CLASS 10 release A 70...80 A release N 1040 A screw terminal standard operating power SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact and tropicalized circuit breakers are optimized, thanks to their low heat loss, for the use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €245,40

  • MS16554 | Abb

    ABB MS16554 | Abb

    Abb MS16554Motor protection MS165-54 In = 40.. 54 A, Ics at 400 V = 25 (kA)

    €229,93

  • EP 941 7 | Abb

    ABB EP 941 7 | Abb

    Abb EP 941 7MS325 1 6-2 5A SWITCH. MOTOR SAVER. 100KA

    €65,55

  • EP 083 8 | Abb

    ABB EP 083 8 | Abb

    Abb EP 083 8MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €45,90

  • 3RV20114AA10 | Siemens

    SIEMENS 3RV20114AA10 | Siemens

    Siemens 3RV20114AA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 10...16 A release N 208 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for the safe separation of the system from the mains. The compact, tropicalized circuit breakers are optimized for use thanks to their low heat loss. in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available. Device variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block. All accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.

    €58,41

  • 3RV20314UA10 | Siemens

    SIEMENS 3RV20314UA10 | Siemens

    Siemens 3RV20314UA10circuit breaker frame size S2 for motor protection, CLASS 10 Release A 32...40 A release N 585 A screw terminal standard operating power SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €179,74

  • SM1P0250 | Lovato

    LOVATO SM1P0250 | Lovato

    Lovato SM1P0250Magneto-thermal motor protection switches with high breaking capacity. The various settings from 0.1 to 40A allow the control and protection of motors up to 22kW (400V). The SM1P... switches have dimensions compliant with the DIN43880 standard which allow them to be mounted in all modular enclosures on the market. They are suitable for isolation in compliance with IEC/EN 60947 standards and can be padlocked in the OFF position without using accessories. The high breaking capacity values ​​allow, in most installations, to avoid the use of fuses.

    €39,71

  • 3RV20110HA10 | Siemens

    SIEMENS 3RV20110HA10 | Siemens

    Siemens 3RV20110HA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 0.55...0.8 A release N 10 A screw terminal standard operating capacity SIRIUS circuit breaker 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized due to their low leakage thermal, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €60,78

  • EP 084 6 | Abb

    ABB EP 084 6 | Abb

    Abb EP 084 6MS116 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €59,05

  • 3RV20111EA10 | Siemens

    SIEMENS 3RV20111EA10 | Siemens

    Siemens 3RV20111EA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 2.8...4 A release N 52 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For Motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low heat loss, for use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €55,04

  • EP 885 6 | Abb

    ABB EP 885 6 | Abb

    Abb EP 885 6 MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. By using switches for motor protection, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between ABB motor protectors and contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €79,72

  • GV2ME03 | Schneider Electric

    SCHNEIDER ELECTRIC GV2ME03 | Schneider Electric

    Schneider Electric GV2ME03GV2ME03 is a Schneider Electric TeSys GV circuit breaker for motors. It ensures thermal-magnetic protection of 0.09 kW motors at 400 V and a high breaking capacity Icu 100 kA. Start-stop control via button guaranteed for 100,000 cycles AC-3 415V. GV2ME03 is a TeSys GV motor circuit breaker from Schneider Electric designed for 0.09 kW motorized applications at 400 V. It meets thermal magnetic protection with a thermal regulation range of 0.25-0.4 A, magnetic tripping at 12 xIn and a high breaking capacity Icu 100 kA at 400 V. Start-stop control via push button guaranteed for 100,000 AC-3 415V cycles. Available worldwide, certified to multiple standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and compliant with Green Premium (RoHS/REACH).

    €62,59

  • 3RV20111HA15 | Siemens

    SIEMENS 3RV20111HA15 | Siemens

    Siemens 3RV20111HA15circuit breaker frame size S00 for motor protection, CLASS 10 release A 5.5...8 A release N 104 A screw terminal standard operating capacity with auxiliary switch block front 1NO+1NC SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized, thanks to their low thermal dispersion, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €86,89

  • 3RV20110CA10 | Siemens

    SIEMENS 3RV20110CA10 | Siemens

    Siemens 3RV20110CA10circuit breaker frame size S00 for motor protection, CLASS 10 release A 0.18...0.25 A release N 3.3 A screw terminal standard operating power Circuit-breaker automatic SIRIUS 3RV2 For motor protection for safe disconnection in the event of a short circuit and for overload protection of loads and the system as well as for safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized thanks to their low heat loss, for use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €53,79

  • 046938 | Eaton

    EATON 046938 | Eaton

    Eaton 046938Motor protection switches according to IEC/EN60947, 3-pole size PKZM0, with adjustable thermal release and instantaneous magnetic release, sensitive to phase failure, screw or snap fixing, with screw terminals screw, cap mounting dimensions 45mm, rated operating voltage Ue 690V, degree of protection IP20, protected against finger contact according to VDE 0106 T. 100, available accessories: auxiliary contacts, voltage release, switching actuator, plate clip

    €80,33

  • EP 946 6 | Abb

    ABB EP 946 6 | Abb

    Abb EP 946 6MS325 12 5-16A SWITCH. MOTOR SAVER. 60KA

    €71,40

  • EP 887 2 | Abb

    ABB EP 887 2 | Abb

    Abb EP 887 2MS132 Motor protection switch with thermal and magnetic protection. Motor protection switches (MMS) are protective devices for main circuits. They combine control and protection in a single device. The motor protection switches integrate in the same device the functions of ON/OFF control, automatic protection for overload, short circuit and phase loss in three-phase asynchronous motors. With the use of motor protection switches, the use of fuses for short circuit protection is avoided, thus resulting in both dimensional and economic savings. Motor protectors can be equipped with a wide range of accessories. The BEA connection kits guarantee a safe and rapid connection between the motor protectors and the ABB contactors. Application: • Short circuit protection • Overload protection • Class 10A tripping • Sensitivity to phase loss • Suitable for isolation • Suitable for three-phase and single-phase applications

    €92,33

  • 3RV20214EA10 | Siemens

    SIEMENS 3RV20214EA10 | Siemens

    Siemens 3RV20214EA10circuit breaker frame size S0 for motor protection, CLASS 10 release A 27...32 A release N 400 A screw terminal standard operating power SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains. The compact, tropicalized circuit breakers are optimized for the use in starters, naturally also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available. Device variants for motor protection are available (also with overload relay function) , system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block. All accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit. The 3RV2 circuit breakers replace the proven 3RV1 series. Simple, efficient, always up-to-date - the SIRIUS modular system.

    €93,94

  • 3RV20214NA10 | Siemens

    SIEMENS 3RV20214NA10 | Siemens

    Siemens 3RV20214NA10circuit breaker frame size S0 for motor protection, CLASS 10 release A 23...28 A release N 364 A screw terminal standard operating capacity SIRIUS 3RV2 circuit breaker For motor protection for safe disconnection in the event of a short circuit and for overload protection of the loads and the system as well as for the safe separation of the system from the mains.\nThe compact, tropicalized circuit breakers are optimized for the Use in starters, of course also for IE3/IE4 motors and equally for direct current switching. International approvals (e.g. IEC and UL/CSA) and versions for applications in potentially explosive areas (ATEX or IEC Ex) are obviously available.\nDevice variants for motor protection are available (also with overload relay function ), system protection, short-circuit protection of combined starters, transformer protection. as a main and EMERGENCY STOP switch and for use in IT networks. They are available with screw or spring-loaded terminals for quick, maintenance-free and vibration-resistant connection as well as optionally with a built-in auxiliary switch block.\nAll accessories such as e.g. auxiliary contact blocks, auxiliary releases, signaling contact blocks etc. they are uniformly suitable for all construction sizes. The various power supply options, such as the SIRIUS 3RV29 power supply system, significantly reduce the wiring of the main circuit.\nThe 3RV2 circuit breakers replace the proven 3RV1 series.\nSimple, efficient, always up-to-date - the SIRIUS modular system.

    €120,25

  • 417308 | Legrand

    LEGRAND 417308 | Legrand

    Legrand 417308Three-phase thermal-magnetic motor protection with lever control - Vn=690V - Ir=4-6A - Im= 78A - Icu= 100kA (at 415Vac) - Pw motors 2.2W. Complies with IEC 60947-1, IEC 60947-2, IEC 60947-4 standards. Adjustable thermal release. Magnetic release calibrated at 13Ie max.

    €102,51

© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account