CONTACTORS
LOVATO 11BG0910A230 | Lovato
Lovato 11BG0910A230THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 9A, COIL IN AC 50/60HZ, 230VAC, 1NO AUXILIARIES
ABB AF09300113 | Abb
Abb AF09300113Three-pole contactor with electronic coil for AC/DC control with screw terminals. AF09 ... AF38 contactors are used to control power circuits up to 690 V AC. and 220 V DC The main fields of use are the control of three-phase motors and resistive or slightly inductive loads. AF09 ... AF38 contactors are equipped with an electronic coil that accepts a wide control voltage Uc in. ... Uc max. AF contactors can handle large fluctuations in the supply voltage. A single coil (e.g.: 100...250 V 50/60 Hz - d.c.) can be used for various supply voltages in use throughout the world. AF contactors have built-in surge protection and do not require additional surge protectors.
LOVATO 11BG0910A400 | Lovato
Lovato 11BG0910A400THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 9A, COIL IN AC 50/60HZ, 400VAC, 1NO AUXILIARIES
LOVATO BF1810A230 | Lovato
Lovato BF1810A230THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 18A, COIL IN AC 50/60HZ, 230VAC, 1NO AUXILIARIES
ABB AF38300013 | Abb
Abb AF38300013Three-pole contactor with electronic coil for AC/DC control with screw terminals. AF09 ... AF38 contactors are used to control power circuits up to 690 V AC. and 220 V DC The main fields of use are the control of three-phase motors and resistive or slightly inductive loads. AF09 ... AF38 contactors are equipped with an electronic coil that accepts a wide control voltage Uc in. ... Uc max. AF contactors can handle large fluctuations in the supply voltage. A single coil (e.g.: 100...250 V 50/60 Hz - d.c.) can be used for various supply voltages in use throughout the world. AF contactors have built-in surge protection and do not require additional surge protectors.
LOVATO BF1210A024 | Lovato
Lovato BF1210A024THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 12A, COIL IN AC 50/60HZ, 24VAC, 1NO AUXILIARIES
LOVATO BF2510A110 | Lovato
Lovato BF2510A110THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 25A, COIL IN AC 50/60HZ, 110VAC, 1NO AUXILIARIES
LOVATO BF0910A230 | Lovato
Lovato BF0910A230THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 9A, COIL IN AC 50/60HZ, 230VAC, 1NO AUXILIARIES
LOVATO 11BG1210A230 | Lovato
Lovato 11BG1210A230THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 12A, COIL IN AC 50/60HZ, 230VAC, 1NO AUXILIARIES
LOVATO BF3800A024 | Lovato
Lovato BF3800A024THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 38A, COIL IN AC 50/60HZ, 24VAC
LOVATO BF1810A024 | Lovato
Lovato BF1810A024THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 18A, COIL IN AC 50/60HZ, 24VAC, 1NO AUXILIARIES
ABB AF12301011 | Abb
Abb AF12301011Three-pole contactor with electronic coil for AC/DC control with screw terminals. AF09 ... AF38 contactors are used to control power circuits up to 690 V AC. and 220 V DC The main fields of use are the control of three-phase motors and resistive or slightly inductive loads. AF09 ... AF38 contactors are equipped with an electronic coil that accepts a wide control voltage Uc in. ... Uc max. AF contactors can handle large fluctuations in the supply voltage. A single coil (e.g.: 100...250 V 50/60 Hz - d.c.) can be used for various supply voltages in use throughout the world. AF contactors have built-in surge protection and do not require additional surge protectors.
LOVATO BF3200A024 | Lovato
Lovato BF3200A024THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 32A, COIL IN AC 50/60HZ, 24VAC
LOVATO 11BG0910D024 | Lovato
Lovato 11BG0910D024THREE-POLE CONTACTOR, OPERATING CURRENT IE (AC3) = 9A, DC COIL, 24VDC, 1NO AUXILIARIES
LOVATO BF40T4A230 | Lovato
Lovato BF40T4A230FOUR-POLE CONTACTOR, OPERATING CURRENT ITH (AC1) = 70A, COIL IN AC 50/60HZ, 230VAC
LOVATO BF65T4A230 | Lovato
Lovato BF65T4A230FOUR-POLE CONTACTOR, OPERATING CURRENT ITH (AC1) = 100A, COIL IN AC 50/60HZ, 230VAC
ABB AF65300011 | Abb
Abb AF65300011The AF40 ... AF96 contactors are mainly used for the control of three-phase motors and circuits with power up to 690 V AC and 220 V DC. These contactors have a block design with 3 main poles. – control circuit: AC operation or d.c. with electronic coil interface accepting a wide range of control voltages (e.g. 100...250 V AC and DC), only 4 coils to cover all control voltages between 24...500 V 50/ 60 Hz and 20...500 V DC - can handle large variations in control voltages - low switchgear energy consumption - very distinct closing and opening – built-in surge suppression – additional auxiliary contact blocks with front or side mounting and a wide range of accessories.
ABB AF96300013 | Abb
Abb AF96300013The AF40 ... AF96 contactors are mainly used for the control of three-phase motors and circuits with power up to 690 V AC. and 220 V DC These contactors have a block design with 3 main poles. – control circuit: AC operation or d.c. with electronic coil interface accepting a wide range of control voltages (e.g. 100...250 V AC and DC), only 4 coils to cover all control voltages between 24...500 V 50/ 60 Hz and 20...500 V dc. - can handle large variations in control voltages - low switchgear energy consumption - very distinct closing and opening – built-in surge suppression – additional auxiliary contact blocks with front or side mounting and a wide range of accessories.
ABB AF40400013 | Abb
Abb AF40400013Contactors used for controlling circuits with power up to 690 V AC and 440 V DC. They are mainly used for the control of non-inductive or weakly inductive loads (e.g. resistance furnaces ...)
ABB AF09301011 | Abb
Abb AF09301011Three-pole contactor with electronic coil for AC/DC control with screw terminals. AF09 ... AF38 contactors are used to control power circuits up to 690 V AC. and 220 V DC The main fields of use are the control of three-phase motors and resistive or slightly inductive loads. AF09 ... AF38 contactors are equipped with an electronic coil that accepts a wide control voltage Uc in. ... Uc max. AF contactors can handle large fluctuations in the supply voltage. A single coil (e.g.: 100...250 V 50/60 Hz - d.c.) can be used for various supply voltages in use throughout the world. AF contactors have built-in surge protection and do not require additional surge protectors.
SCHNEIDER ELECTRIC LC1D09BD | Schneider Electric TeSys LC1D contactor
Schneider Electric TeSys LC1D contactor LC1D09BD LC1D09BD is a compact 3-pole TeSys D contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW at 400V, includes a 24V DC coil and 1NO+1NC auxiliary contacts. It can be used in safety applications thanks to the certified NC mirror contact. Compact, with DIN rail mounting, it guarantees high reliability and durability. Available worldwide, it is certified to various standards (IEC, UL, CSA, CCC, EAC, for use in marine environments) and is Green Premium compliant (RoHS/REACH). Technical characteristics: Motor power [Kw] 2.2 kW at 220...230 V AC 50/60 Hz (AC-3) 4 kW at 380...400 V AC 50/60 Hz (AC-3)4 kW at 415...440 V AC 50/60 Hz (AC-3)5.5 kW at 500 V AC 50/60 Hz (AC-3)5.5 kW at 660...690 V AC 50/60 Hz (AC-3)2.2 kW at 400 V AC 50/60 Hz (AC-4)2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)4 kW at 380...400 V AC 50/60 Hz (AC-3e) )4 kW at 415...440 V AC 50/60 Hz (AC-3e)5.5 kW at 500 V AC 50/60 Hz (AC-3e)5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)Motor Power In Hp 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 200/208 V AC 50/60 Hz for 3 phase motors2 hp at 230/240 V AC 50/60 Hz for 3 phase motors5 hp at 460/480 V AC 50/60 Hz for 3 phase motors 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motorsCompatibility Code LC1DComposition Contact Pole 3 NOCompatibility Contact M4Protective Cover WithConventional Thermal CurrentIn Open Air [Ith]25 A (at 60 °C) for Power Circuit10 A ( at 60 °C) for signaling circuitNominal Making Power Irms 250 A at 440 V for Power circuit conforming to IEC 60947140 A AC for signaling circuit conforming to IEC 60947-5-1250 A DC for signaling circuit conforming to IEC 60947-5-1
SCHNEIDER ELECTRIC LC1D258B7 | Schneider Electric
Schneider Electric LC1D258B7LC1D258B7 is a 4-pole (2NO+2NC) TeSys D contactor from Schneider Electric for AC-1 load applications up to 40A/690V. Provides an AC coil 24 V 50/60 Hz, integrated auxiliary contacts 1NO+1NC (NC mirror contact) and connection via screw terminals. Compact, with DIN rail mounting, it guarantees high reliability and durability. Available worldwide, it is certified to multiple standards (IEC, UL, CSA, CCC, EAC, Marine) and compatible with Green Premium (RoHs/Reach).
SIEMENS 3RT20453KB40 | Siemens
Siemens 3RT20453KB40power contactor, AC-3e/AC-3, 80 A, 37 kW / 400 V, 3-pole, DC 24 V, 0.8-1.2* US, with integrated varistor, auxiliary contacts: 1 NO + 1 NC, integrated varistor, main circuit: screw connection, control circuit and auxiliary circuit: spring terminals, suitable for PLC outputs SIRIUS 3RT2 interface contactor for control of motors and auxiliary and control circuits, especially for direct connection to electronic control equipment.\nThe 3RT2 contactors are an integral part of the SIRIUS modular system with its products perfectly coordinated with each other. They convince with great power in a compact design and high contact reliability. They can be combined in different ways with other components in the starter. Many of the device combinations are already tested at the factory. Integrated auxiliary switch blocks reduce mounting complexity. Front connections simplify simple wiring. The 3RT2 contactors are tropicalized, approved worldwide (e.g. IEC and UL/CSA) and IE3/IE4ready.\nThe devices are available not only with screw terminals but also with spring-loaded terminals for quick, maintenance-free connection and vibration-resistant.\nSimple, efficient, always up-to-date - the SIRIUS modular system.
SIEMENS 3RT20351AF04 | Siemens
Siemens 3RT20351AF04Power contactor, AC-3 40 A, 18.5 kW / 400 V 2 NO+2 NC, AC 110 V 50 Hz, 3-pole, size S2, screw terminal SIRIUS 3RT2 power contactor for controlling motors.\nThe 3RT2 contactors are an integral part of the SIRIUS modular system with its products perfectly coordinated with each other. They convince with great power in a compact design and high contact reliability. They can be combined in various ways with other components in the starter. Many of the device combinations are already tested at the factory. The contactors offer the optimal connection to the controller for every application (parallel, via AS-i or IO-Link). Integrated auxiliary switch blocks reduce mounting complexity. Front connections simplify simple wiring. The 3RT2 contactors are tropicalized, approved worldwide (e.g. IEC and UL/CSA) and IE3/IE4ready.\nThey are available in various sizes and in a wide power range for AC and DC control. The devices are available not only with screw terminals but also with spring-loaded terminals for quick, maintenance-free and vibration-resistant connection.\nAll accessories such as e.g. the auxiliary contact blocks, the auxiliary releases etc. they are uniformly suitable for all construction sizes. The available connection modules, function modules and the SIRIUS 3RV29 power supply system significantly reduce the wiring effort.\nThe 3RT2 power contactors replace the proven 3RT1 series (up to 55 kW).\nSimple, efficient, always up-to-date - the SIRIUS. modular system