FINDER POWER DISTRIBUTION
FINDER 131182300000 | Finder call/reset relay din 17.5mm 1co
Finder call/reset relay din 17.5mm 1co 131182300000 Bistable call relay with reset command, changeover contact. Bistable operation with reset command particularly suitable for applications in the tertiary sector - public bathrooms, hospitals, hotels.Mounting on 5 mm bar Width 17.5 mm Features: Bistable operation with reset command particularly suitable for applications in the tertiary sector: public bathrooms, hospitals, hotels Mounting on 35 mm rail (EN 60715) or panel Contact configuration: 1 Exchange Nominal contact current: 12 A Dimensions: 17.5x84x56.5 mm Nominal /voltage: 230 V Nominal contact voltage: 250 V AC
FINDER 7P2782750020 | Finder surge arrester
Finder surge arrester 7P2782750020 7P.27 Type 2 surge arrester (2 varistors) for single-phase TN systems with Neutral with L, N-PE varistor protection and replaceable varistor modules.Available with remote contact for signaling the status of the varistor. Features: Suitable for AC and DC systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of the status of the varistor - working/to be replaced Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Varistor and spark gap modules, replaceable Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715), 17.5 mm per pole
FINDER 7M2482300210 | Finder bidirectional single-phase energy meter with LCD display
Finder bidirectional single-phase energy meter with LCD display 7M2482300210 The bidirectional single-phase energy meters with LCD display Type 7M.24.8.230.0001, Type 7M.24.8.230.0010, Type 7M.24.8.230.0210 and Type 7M.24.8.230.0310 are the ideal solution for monitoring domestic consumption/ industrial and specifically they can be used in offices, for photovoltaic systems and for energy metering in campsites. They are programmable via smartphone thanks to NFC technology, which allows you to read the measured energy even in the absence of the mains. They are also distinguished by the touch navigation and programming button and the power and control terminals with integrated anti-theft lock. Other features: 4 MID certified meters for imported and exported active and reactive energy 8 resettable counters for active, reactive, apparent absolute, imported and exported energy Extensive measurements available: V, I, Pf, f, THD of voltage and current and operating time for preventive maintenance activities Mbus and Modbus RS485 communication protocol Technical data: Type of meter: ElectronicRated current (In): 5 AMaximum current (Imax): 40 A Nominal voltage (Un) N-L: 230...230 VFrequency: 50...60 Hz Accuracy class: BPolarity type: Single phaseModel: Direct measurement Type of energy measured: Active and reactive powerPulse output: NoneType of indication: Digital Mounting method: DIN RailWidth in number of modules: 1 Interface type: ModbusNumber of digits: 7 Protection degree (IP): IP50
FINDER 7M2482300110 | Finder Bidirectional single-phase energy meter
Finder Bidirectional single-phase energy meter 7M2482300110 The bidirectional single-phase energy meters with LCD display Type 7M.24.8.230.0001, Type 7M.24.8.230.0010, Type 7M.24.8.230.0210 and Type 7M.24.8.230.0310 are the ideal solution for monitoring domestic consumption/ industrial and specifically they can be used in offices, for photovoltaic systems and for energy metering in campsites. They can be programmed via smartphone thanks to NFC technology, which allows you to read the measured energy even in the absence of the mains. They are also distinguished by the touch navigation and programming button and the power and control terminals with integrated anti-theft lock. Technical specifications:Type of meterElectronicRated current (In)5 AMaximum current (Imax)40 ANominal voltage (Un) N-L230...230 VFrequency50...60 HzPrecision classBType of polaritySingle phaseModelDirect measurementType of energy measuredActive and reactive powerCertifiedNationalPulse outputElectricPulse typeS0Pulse output frequency1000...1000 Imp/kWh (kType of indicationDigitalMounting methodDIN railWidth in number of modules 1Type of interfaceOthersNumber of digits7Degree of protection (IP)IP50
FINDER 223400244320 | Finder 25 A modular contactor
Finder modular contactor 25 A 223400244320 Modular contactor 25 A - 4 contacts, 35mm width and a NO contact opening ≥ 3 mm, double break. Type 22.34 complies with EN 61095: 2009 Technical description: Modular contactor, 25 A, 4 contacts, NO, 25 A, AgSnO2, AC/DC coil, 24 V, operation from 19.2 to 26.4 V (AC)/( DC), rated power 2 VA (AC) / 2.2 W (DC), holding voltage 9.6 V (AC)/(DC), release voltage 2.4 V (AC)/(DC), variant: Mechanical indicator + LED, ambient temperature from -25 to +50 °C
FINDER 223200124520 | Finder modular contactor
Finder modular contactor 223200124520 Modular contactor 25 A, 2 contacts, 17.5mm width, NO contact opening ≥ 3 mm, double break. Suitable for railway applications; plastic materials compliant with fire and smoke regulations (EN 45545-2 + A1: 2016). Technical description: Modular contactor, 25 A, 2 contacts, 1 NO + 1 NC, 25 A, AgSnO2, AC/DC coil, 12 V, operation from 9.6 to 13.2 V (AC)/(DC), rated power 2 VA (AC) / 2.2 W (DC), hold voltage 4.8 V (AC)/(DC), release voltage 1.2 V (AC)/(DC), variant: Mechanical indicator + LED, ambient temperature from -25 at +50 °C.
FINDER 223200124340 | Finder Modular contactor
Finder Modular contactor 223200124340 25 A modular contactor, 2 contacts, 17.5mm width, NO contact opening ≥ 3 mm, double break. Suitable for railway applications; plastic materials compliant with fire and smoke regulations (EN 45545-2 + A1: 2016). Technical description: Modular contactor, 25 A, 2 contacts, NO, 25 A, AgSnO2, AC/DC coil, 12 V, operation from 9.6 to 13.2 V (AC)/(DC), rated power 2 VA (AC ) / 2.2 W (DC), hold voltage 4.8 V (AC)/(DC), release voltage 1.2 V (AC)/(DC), variant: Manual selector + mechanical indicator + LED, ambient temperature -25 to +50 °C.
FINDER 7P2397500020 | Finder surge arrester (SPD) type 2
Finder surge arrester (SPD) type 2 7P2397500020 Surge arrester SPD 7P.23.9 type 2 (3 varistors) for systems1020 V DC photovoltaics.Protects devices and equipment from direct and/or induced surges.Replaceable modules.Available with remote contact for varistor status reporting. Technical characteristics:Remote Contact: Remote Indication: Without Remote Signaling ContactRated discharge current: 20 kaDimensions: 53.8x89.6x65.9 mmAmbient temperature: -40...80 CRated voltage: 375 V DC
FINDER 7P2582750020 | Finder Surge Arrester (SPD) type 2
Finder Surge arrester (SPD) type 2 7P2582750020 Surge arrester 7P.25 Type 2 (4 varistors), for three-phase applications, with TN-S with Neutral, varistor protection L1, L2, L3, N-PE, varistor modules replaceable.Replaceable modules, available with remote contact for varistor status reporting. Technical characteristics:Remote Contact: Remote Indication: Without Remote Signaling ContactRated discharge current: 20 kaDimensions: 71.8x84.1x65.9 mmAmbient temperature: -40...80 CRated voltage: 275 V AC
FINDER 131200240000 | Bistable Relay Finder with 8 A reset control
Bistable Relay Finder with reset command at 8 to 131200240000 Bistable call relay Type 13.12 with reset control - 1 exchange + 1 NO - mounting on 35 mm bar (EN 60715). Width 17.5mm. Technical characteristics:Contact configuration: 1 Exchange + 1 NORated current contacts: 8 ADimensions: 17.5x84x56.5 mmSupply voltage: 24 VNominal voltage contacts: 250 V ACPower Supply Type: AC/DC Power Supply TypeInstallation type: Modular bistable, 35 mm bar mounting (EN 60715), width 17.5mm
FINDER 131200120000 | Bistable Relay Finder with reset control 8 A
Bistable Relay Finder with Reset Command 8 A 31200120000 Bistable call relay Type 13.12 with reset control - 1 exchange + 1 NO - mounting on 35 mm bar (EN 60715). Width 17.5mm. Technical characteristics:Contact configuration: 1 Exchange + 1 NORated current contacts: 8 ADimensions: 17.5x84x56.5 mmSupply voltage: 12 VNominal voltage contacts: 250 V ACPower Supply Type: AC/DC Power Supply TypeInstallation type: Modular bistable, 35 mm bar mounting (EN 60715), 17.5 mm width
FINDER 7E1282300002 | Finder energy meter
Finder energy meter 7E1282300002 Type 7E.12 single-phase energy meter with horizontal mechanical display and S0 pulse interface. Rated current 10 (25 A maximum), single phase 230 V AC, kWh, No MID, integrated S0 pulse output. Width 35 mm. Features: Complies with EN 62053-21 and EN 50470 (Physikalisch – Technischen Bundesanstalt) Precision class 1/B Protection category II Impulsive S0 interface compliant with EN 62053-31 for remote energy control Accessories: tamper-proof sealable terminal covers Reduced size Mounting on 35 mm rail (EN 60715)