FINDER EARTH PROTECTIONS AND LIGHTNING PRODUCTS

6 products

  • 7P2782750020 | Finder surge arrester

    FINDER 7P2782750020 | Finder surge arrester

    Finder surge arrester 7P2782750020 7P.27 Type 2 surge arrester (2 varistors) for single-phase TN systems with Neutral with L, N-PE varistor protection and replaceable varistor modules.Available with remote contact for signaling the status of the varistor. Features: Suitable for AC and DC systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of the status of the varistor - working/to be replaced Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Varistor and spark gap modules, replaceable Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715), 17.5 mm per pole

    €72,95

  • 7P3682752003 | Finder surge arrester (SPD) type 3 275VAC 6KV 3

    FINDER 7P3682752003 | Finder surge arrester (SPD) type 3 275VAC 6KV 3

    FINDER Surge Discharger (SPD) TYPE 3 275VAC 6KV 3 7P3682752003 Surge arrester, Type 7P.36 type 3 for systems with TT and TN-S neutralSingle-phase applications for built-in installation (503 boxes) and on DIN rail.Allows easy additional protection against surges in existing wall sockets.Y-shaped configuration with acoustic signaling in case of varistor failure and acoustic test function.Equipped with 3 wires of 150 mm length for a direct connection to the socket terminals . Mounting: apparent/recessed with telecommunications contact: no number of poles: 1 max. permanent AC voltage: 275 V. rated impulse leakage current (8/20) (L-N): 3 kA. nominal voltage AC: 230 V. test class type 3: yes protection level L-N: 1.65 kV. signaling in the luminaire: acoustic Degree of protection: IP20 with anti-interference filter: no Features: Protects sensitive electrical and electronic devices from impulse surges Complies with EN 61643-11:2012 ApplicationsControl panelsSurge protectionApparatus for road use, tunnelsElevator - elevatorsControl panels, distribution

    €28,15

  • 7P2482750020 | <tc>Finder</tc> surge arrester (SPD) type 2 4 poles 20KA| three-phase

    FINDER 7P2482750020 | Finder surge arrester (SPD) type 2 4 poles 20KA| three-phase

    Finder surge arrester (SPD) type 2 4 poles 20KA | three-phase 7P2482750020 Surge arresters. Mounting: 35 mm blind bar with telecommunications contact: no number of conductors (excluding earth): 4 size: 4 UM max. permanent AC voltage: 275 V. rated impulse leakage current (8/20): 20 kA. nominal voltage AC: 230 V. test class type 2: yes protection level L-N: 1.2 kV. signaling in the device: optical permanent voltage DC max.: 350 V. Degree of protection: IP20 protection level N-PE: 1.5 kV. integrated auxiliary fuse: no mains form DC: no mains form IT: no mains form TN: no mains form TN-C: no mains form TN-S: yes mains form TT: yes other mains forms: no network form TN-C-S: no max. discharge current (8/20): 40 kA. short circuit resistance (Isccr): 50 kA. Replaceable modules, available with remote contact for signaling the status of the varistor. Features: Suitable for 230 V/400 V systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of varistor status - working/needs replacement Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Replaceable varistor and spark gap modules Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715) ApplicationsControl panels, distributionApparatus for road use, tunnelsElevators - elevatorsControl panelsSurge protection

    €95,90

  • 7P2390000015 | Finder Surge arrester (SPD) type 2 | photovoltaic SPD class 2 for photovoltaic 1020VDC 15KA

    FINDER 7P2390000015 | Finder Surge arrester (SPD) type 2 | photovoltaic SPD class 2 for photovoltaic 1020VDC 15KA

    FINDER Surge arrester (SPD) TYPE 2 | PHOTOVOLTAIC SPD class 2 for photovoltaic 1020VDC 15KA 7P2390000015 Surge arresters. Mounting: 35 mm blind bar with telecommunications contact: no number of conductors (excluding earth): 2 size: 3 UM max. permanent AC voltage: 275 V. rated impulse leakage current (8/20): 20 kA. nominal voltage AC: 230 V. test class type 2: yes protection level L-N: 1.2 kV. signaling in the device: optical continuous voltage DC max.: 350 V. Degree of protection: IP20 max. PV voltage: 420 V. N-PE protection level: 1.2 kV. integrated auxiliary fuse: no mains form DC: no mains form IT: no mains form TN: yes mains form TN-C: yes mains form TN-S: no mains form TT: no other mains forms: no network form TN-C-S: yes max. discharge current (8/20): 30 kA. Features: Protects devices and equipment from direct and/or induced overvoltages.Replaceable modules.Available with remote contact for signaling the status of the varistor. Features: Visual indicator of the status of the varistor – in case of failure Remote contact signaling of the status of the varistor in the event of a fault. Connector (07P.01) included in the package (depending on versions) Replaceable modules Complies with prEN 50539-11:2012 Mounting on 35 mm rail (EN 60715) ApplicationsControl panels, distributionControl panelsSurge protectionAppliances for road use, tunnelsElevators - lifts

    €62,00

  • 7P2282750020 | Finder SPD limiter class 2 single phase 2P 275VAC 1+1 20KA

    FINDER 7P2282750020 | Finder SPD limiter class 2 single phase 2P 275VAC 1+1 20KA

    FINDER SPD limiter class 2 single phase 2P 275VAC 1+1 20KA 7P2282750020 Surge arresters. 7P.22 Type 2 (1 varistor + 1gas spark gap) for single-phase TT and TN-S systems with Neutral. L-N varistor protection + N-PE gas spark gap and with replaceable varistor and spark gap modules.Available with remote contact for signaling the varistor status. Mounting: 35 mm blind bar with telecommunications contact: no number of conductors (excluding earth): 2 size: 2 UM max. permanent AC voltage: 275 V. rated impulse leakage current (8/20): 20 kA. nominal voltage AC: 230 V. test class type 2: yes protection level L-N: 1.2 kV. signaling in the luminaire: optical Protection degree: IP20 N-PE protection level: 1.5 kV. integrated auxiliary fuse: no mains form DC: no mains form IT: no mains form TN: no mains form TN-C: no mains form TN-S: yes mains form TT: yes other mains forms: no form of the TN-C-S network: no max. discharge current (8/20): 40 kA. short circuit resistance (Isccr): 50 kA. Features: Suitable for AC and DC systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of varistor status - working/needs replacement Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Varistor and spark gap modules, replaceable Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715), 17.5 mm per pole ApplicationsControl panels, distributionControl panelsSurge protectionAppliances for road use, tunnelsElevators - lifts

    €54,65

  • 7P2182750020 | <tc>Finder</tc> surge arrester (SPD) type 2 | AC single phase - DC three phase

    FINDER 7P2182750020 | Finder surge arrester (SPD) type 2 | AC single phase - DC three phase

    Finder surge arrester (SPD) TYPE 2 | AC single phase - DC three phase 7P2182750020 7P.21 Type 2 (1 varistor) unipolar surge arrester for use in DC applications or single-phase AC low voltage systems. Varistor protection +/– or L/N (GND); –/+ or GND (L/N).Replaceable module. Available with remote contact for signaling the status of the varistor. Features: Suitable for AC and DC systems/applications for protection against induced and switching overvoltages To be installed on the border between the LPZ 1 and LPZ 2 zones Visual indicator of the status of the varistor – working/to be replaced Remote contact signaling of the varistor status. Connector (07P.01) included in the package (depending on versions) Varistor and spark gap modules, replaceable Complies with EN 61643-11:2012 Mounting on 35 mm rail (EN 60715), 17.5 mm per pole Also available in the versions: – 7P.21.8.130.1015 SPD Type 2 unipolar usable in DC applications or low voltage single-phase AC systems Varistor protection +/– or L/N (GND); –/+ or GND (L/N) Replaceable module – 7P.21.8.275.x020 SPD Type 2 unipolar usable in single-phase or three-phase applications (230/400 V) Varistor protection L/N(GND)-GND/(L/N) Replaceable module 7P.21.8.440.x020 SPD Type 2 unipolar for three-phase systems with nominal voltage 400 V AC Varistor protection L/N(GND)-GND/(L/N) Replaceable module Applications Control panels, distributionBedroom light controlSurge protectionApparatus for road use, tunnelsElevators - lifts

    €31,00

© 2024 DMS S.R.L. VAT IT04742820618

DMSTECHMART is not a distributor or representative of the brands featured on this site. All product names, logos and trademarks are the property of their respective owners. All company, product and service names used on this site are for identification purposes only.

    • American Express