FREE SHIPPING throughout Europe.

6EP14362BA10 | Siemens sitop PSU300S 20 A 

Description

SIEMENS SITOP PSU300S 20 A (DC 24) 6EP14362BA10

Stabilized power supply input: 3 AC 400 ... 500 V output: DC 24 V/20 A *Ex approval no longer available*

Entrance

form of the three-phase AC electrical network
supply voltage with AC
● nominal value min. 400 V
● rated value max. 500 V
● initial value 340 V
● final value 550 V
execution of the input wide-range input Yes
backup operating condition for lack of mains voltage
With Ue = 400 V
buffering time with nominal value of the output current in case of mains voltage failure min.
6 ms
backup operating condition due to mains voltage failure
With Ue = 400 V
mains frequency
● 1 nominal value 50 Hz
● 2 nominal value 60 Hz
mains frequency 47 ... 63 Hz
input current
● with value rated input voltage 400 V 1.2 A
● at rated input voltage 500 V 1 A
current limitation of the inrush current to 25 °C max. 36 A
I2t value max. 0.9 A² s
Protection design No
● of the mains cable Required: 3-pole circuit breaker with 3-pole coupling 6 ... 16 A
characteristic C or circuit breaker 3RV2011-1DA10 (set to 3 A ) or 3RV2711-1DD10 (UL 489-listed, DIVQ)

Product form

SIEMENS SITOP PSU300S 20 A (DC 24) 6EP14362BA10 Stabilized power supply input: 3 AC 400 ... 500 V output: DC... Read more

SKU: 6EP1436-2BA10
Barcode: 4025515151388

IN STOCK

IT €370,58
€303,75 Excl. VAT

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 8504.40
    Icon for cloud_dataSPECIFICATIONS

    Icon for verifiedDOCUMENTATION
    Icon for coinCUSTOM QUOTE

    Our Sales Team will be at your disposal.

    Send us a message!

    Description

    SIEMENS SITOP PSU300S 20 A (DC 24) 6EP14362BA10

    Stabilized power supply input: 3 AC 400 ... 500 V output: DC 24 V/20 A *Ex approval no longer available*

    Entrance

    form of the three-phase AC electrical network
    supply voltage with AC
    ● nominal value min. 400 V
    ● rated value max. 500 V
    ● initial value 340 V
    ● final value 550 V
    execution of the input wide-range input Yes
    backup operating condition for lack of mains voltage
    With Ue = 400 V
    buffering time with nominal value of the output current in case of mains voltage failure min.
    6 ms
    backup operating condition due to mains voltage failure
    With Ue = 400 V
    mains frequency
    ● 1 nominal value 50 Hz
    ● 2 nominal value 60 Hz
    mains frequency 47 ... 63 Hz
    input current
    ● with value rated input voltage 400 V 1.2 A
    ● at rated input voltage 500 V 1 A
    current limitation of the inrush current to 25 °C max. 36 A
    I2t value max. 0.9 A² s
    Protection design No
    ● of the mains cable Required: 3-pole circuit breaker with 3-pole coupling 6 ... 16 A
    characteristic C or circuit breaker 3RV2011-1DA10 (set to 3 A ) or 3RV2711-1DD10 (UL 489-listed, DIVQ)

    • Warranty

      Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • <tc>Telephone</tc>

      Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT 04742820618

    DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

      • Amazon
      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account