Description
Schneider-Electric Security Module, Harmony XPS XPSUVN11AP
Safety module, Harmony XPS, zero speed control with timing, 24V, screw terminals
Technical data
Product Range
Harmony Safety Automation
Product Type
Safety module
Name
Safety Module star-delta motor supplied by variable speed drive
Monitoring 3-phase motor supplied by servo drive
Controlling enegization to open of guard switch type XCSE, XCSLE, >Can reach PL e/category 3 for NO relay contact conforming to ISO 13849-1
Can reach SILCL 3 for NO relay contact conforming to IEC 62061
Can reach SIL 3 for NO relay contact conforming to IEC 61508
Reliability Data Safety
MTTFd > 30 years compliant with ISO 13849-1
Dcavg = 98.9 % compliant with ISO 13849-1
PFHd = 2.39E-9 1/ h conforming to ISO 13849-1
HFT = 1 conforming to IEC 62061
PFHd = 2.39E-9 1/h conforming to IEC 62061
SFF > 99% conforming to IEC 62061
HFT = 1 conforming to IEC 61508-1
PFHd = 2.39E-9 1/h conforming to IEC 61508-1
SFF > 99% conforming to IEC 61508-1
Type = B conforming to IEC 61508-1
Product Certifications
TÜV
cULus
Nominal Power Voltage [Us]
24 V AC - 15...10 %
24 V DC - 20...20 %
Output Type
Relay, 1 NO circuits, potential-free
Number of Additional Circuits
2 static outputs
Maximum Consumption In W
2.0 W
Maximum Power Consumption In Va
5.5 VA
Input Voltage
690 V
Input Detection Threshold
50 mV
65 mV
85 mV
110 mV
140 mV
180 mV
230 mV
300 mV
400 mV
500 mV
Timing
0.5 s
1 s
2 s
3 s
5 s
8 s
12 s
20 s
35 s
60 s
Rated Operating Current [Ie]
5 A AC-1 for NO relay contact
3 A AC-15 for NO relay contact
5 A DC-1 for NO relay contact
3 A DC-13 for NO relay contact
Conventional Thermal Current In Air [Ith]
6 A for NO relay output circuit
Associated Fuse Rating
6 A gG for relay output compliant with IEC 60947-1
Standards I
EC 60947-5-1
IEC 61508-1 function standard safety function
IEC 61508-2 standard safety function
IEC 61508-3 standard safety function
IEC 61508-4 standard safety function
IEC 61508-5 standard safety function
IEC 61508-6 standard safety function
IEC 61508-7 standard safety function
ISO 13849-1 standard safety function
IEC 62061 standard safety function
Minimum Output Current
10 mA for relay output
Minimum Output Voltage
5 V for relay output
Nominal Insulation Voltage[Ui]
690 V phase to phase (pollution degree 2) conforming to IEC 60947-1
400 V phase to earth (pollution degree 2) conforming to IEC 60947-1
Rated Impulse Withstand Voltage [Uimp]
4 kV overvoltage category II conforming to IEC 60947-1
Local Signaling
Green LED with power markings for Power ON
Red LED with error markings for error
Yellow LED with state markings for status
Yellow LED with L12 markings for input line comparison
Yellow LED with L32 markings for input line comparison
Connections - Terminals
Removable screw terminal block solid or flexible cable: 0.2...2.5 mm²
Removable screw terminal block flexible with ring nut cable: 0.25...2.5 mm² conductor
single
Removable screw terminal block solid or flexible cable: 0.2...1.5 mm² double conductor
Removable screw terminal block flexible with ring nut cable: 2 x 0.25...1 mm² without
cable end, with bezel
Flexible removable screw terminal block with cable ring: 2 x 0.5...1.5 mm² with
cable end, with bezel
Installation
Symmetrical DIN rail 35 mm
Depth
120 mm
Height
100 mm
Width
22, 5 mm
Product Weight
0.2 kg