Description
Schneider Electric LC1D806FW
TeSys D contactor, 3p (3 NO), AC3, <= 440 V 80A, wide range 110 Vdc. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC 25...400 Hz for power circuit, <= 690 V AC for power circuit - Rated operational current [Ie]: 125 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit, 80 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit - motor power in kW: 22 kW at 220...230 V AC 50/60 Hz AC-3, 37 kW at 380...400 V AC 50/60 Hz AC-3, 45 kW at 660...690 V AC 50/60 Hz AC-3, 55 kW at 500 V AC 50/60 Hz AC-3 - motor power in hp: 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 20 hp at 200/ 208 VAC 50/60 Hz for 3 phase motors, 25 hp at 230/240 VAC 50/60 Hz for 3 phase motors, 60 hp at 460/480 VAC 50/60 Hz for 3 phase motors, 60 hp a575/ 600 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 115 V AC 50/60 Hz for 1 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Conventional thermal current in air open [Ith]: 10 A at <= 60 °C for signaling circuit, 125 A at <= 60 °C for power circuit - nominal making capacity Irms: 1100 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signaling circuit conforming to IEC 60947-5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1 - Rated short-time withstand current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 135 A <= 40 °C 10 min power circuit, 140 A 100 ms signaling circuit, 320 A <= 40 °C 1 min power circuit, 640 A <= 40 °C 10 s power circuit, 990 A <= 40 °C 1 s power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 160 A gG at <= 690 V type 2 coordination for power circuit, 200 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 1000 V for power circuit compliant with IEC 60947-4-1, 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600V for signaling circuit CSA certifications, 600 V for signaling circuit UL certifications, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 0.8 Mcycles 125 A AC-1 at Ue <= 440 V, 1.5 Mcycles 80 A AC-3 at Ue <= 440 V - power dissipation per pole: 12.5 W AC-1, 5.1 W AC-3 - protective cover: with - mounting support: guide, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC , CSA,DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit: nut connection terminals - external diameter: 8 mm, power circuit: nut connection terminals - external diameter: 17 mm, power circuit: busbars 1 4 x 16 mm - tightening torque: control circuit: 1.7 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, circuit control: 1.7 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M3.5, power circuit: 9 Nm - on nut connection terminals - with flat screwdriver Ø 8 mm screw: M6 , power circuit: 9 Nm - on connection terminals with 10 mm hexagonal nut screw: M6, power circuit: 9 Nm - on busbars - with flat screwdriver Ø 8 mm screw: M6, power circuit: 9 Nm - on busbars hexagonal 10 mm screw: M6 - operating time: 20...35 ms opening, 95...130 ms closing - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 10 mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..