FREE SHIPPING throughout Europe

LC1D38SD | Schneider Electric

Description

Schneider Electric LC1D38SD

TeSys LC1D contactor, 3 poles, AC3 440V 38A, 72 V DC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 38 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 18.5 kW at 380...400 V AC 50/60 Hz AC-3, 18.5 kW at 415...440 V AC 50/60 Hz AC-3, 18.5 kW at 500 V AC 50/60 Hz AC-3, 18.5 kW at 660...690 VAC 50/60 Hz AC-3, 9 kW at 220...230 V AC 50/60 Hz AC-3 - motor power in hp: 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 480 V AC 50/60 Hz for 3 phase motors, 25 hp at 600 V AC 50/60 Hz for 3 phases motors, 5 hp at 240 V AC 50/60 Hz for 1 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Thermal current conventional in open air [Ith]: 10 A at <= 60 °C for signaling circuit, 50 A at <= 60 °C for power circuit - nominal making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947- 5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947 - Rated short-time withstand current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 150 A <= 40 °C 1 min power circuit, 310 A <= 40 °C 10 s power circuit, 430 A <= 40 °C 1 s circuit dipower, 60 A <= 40 °C 10 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 63 A gG at <= 690 V type 1 coordination for power circuit , 63 A gG at <= 690 V type 2 coordination for power circuit - Rated insulation voltage [Ui]: 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications , 600 V for signaling circuit UL certifications, 690 V for power circuit compliant with IEC 60947-4-1, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 1.4 Mcycles 38 A AC-3 to Ue <= 440 V, 1.4 Mcycles 50 A AC-1 at Ue <= 440 V - power dissipation per pole: 3 W AC-3, 5W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA , DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit: screw fixing terminals 1 cables 1...4 mm² - cable rigidity: flexible - with cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable rigidity: flexible - without cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable rigidity: solid - without cable end, control circuit: screw fastening terminals 2 cables 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit: screw fastening terminals 2 cables 1...4 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 2 cables 1...4 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cables 1, 5...10 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cable 1...10 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit: screw fixing terminals 2 cables 1.5...6 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 2 cables 2.5...10 mm² - cable stiffness: flexible - without cable end, circuit power: screw fixing terminals 2 cables 2.5...10 mm² - cable stiffness: solid - without cable end - tightening torque: control circuit: 1.7 Nm - on screw fixing terminals - with screwdriver Philips No 2, control circuit: 1.7 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm, power circuit: 2.5 Nm - on screw fixing terminals - with Philips No 2 screwdriver, circuit power: 2.5 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm - operating time: 16...24 ms opening, 53.55...72.45 ms closing - Safety reliability level : B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 30 Mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

Product form

Schneider Electric LC1D38SDTeSys LC1D contactor, 3 poles, AC3 440V 38A, 72 V DC. range: TeSys - product name: TeSys D... Read more

SKU: LC1D38SD
Barcode: 3389110360820

IT €153,73
€126,01 Excl. VAT

  •  Su ordinazione - Consegna in 3 settimane
  • STANDARD RETURN
  • QUICK DELIVERY ASSURED
  • HS CODE: 85364900
Icon for verifiedDOCUMENTATION

Documentation not available

Description

Schneider Electric LC1D38SD

TeSys LC1D contactor, 3 poles, AC3 440V 38A, 72 V DC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 38 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 18.5 kW at 380...400 V AC 50/60 Hz AC-3, 18.5 kW at 415...440 V AC 50/60 Hz AC-3, 18.5 kW at 500 V AC 50/60 Hz AC-3, 18.5 kW at 660...690 VAC 50/60 Hz AC-3, 9 kW at 220...230 V AC 50/60 Hz AC-3 - motor power in hp: 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 480 V AC 50/60 Hz for 3 phase motors, 25 hp at 600 V AC 50/60 Hz for 3 phases motors, 5 hp at 240 V AC 50/60 Hz for 1 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Thermal current conventional in open air [Ith]: 10 A at <= 60 °C for signaling circuit, 50 A at <= 60 °C for power circuit - nominal making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947- 5-1, 250 A DC for signaling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947 - Rated short-time withstand current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 150 A <= 40 °C 1 min power circuit, 310 A <= 40 °C 10 s power circuit, 430 A <= 40 °C 1 s circuit dipower, 60 A <= 40 °C 10 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 63 A gG at <= 690 V type 1 coordination for power circuit , 63 A gG at <= 690 V type 2 coordination for power circuit - Rated insulation voltage [Ui]: 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications , 600 V for signaling circuit UL certifications, 690 V for power circuit compliant with IEC 60947-4-1, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 1.4 Mcycles 38 A AC-3 to Ue <= 440 V, 1.4 Mcycles 50 A AC-1 at Ue <= 440 V - power dissipation per pole: 3 W AC-3, 5W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA , DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit: screw fixing terminals 1 cables 1...4 mm² - cable rigidity: flexible - with cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable rigidity: flexible - without cable end, control circuit: screw fixing terminals 1 cable 1...4 mm² - cable rigidity: solid - without cable end, control circuit: screw fastening terminals 2 cables 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit: screw fastening terminals 2 cables 1...4 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 2 cables 1...4 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cables 1, 5...10 mm² - cable stiffness: solid - without cable end, power circuit: screw fixing terminals 1 cable 1...10 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 1 cable 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit: screw fixing terminals 2 cables 1.5...6 mm² - cable stiffness: flexible - with cable end, power circuit: screw fixing terminals 2 cables 2.5...10 mm² - cable stiffness: flexible - without cable end, circuit power: screw fixing terminals 2 cables 2.5...10 mm² - cable stiffness: solid - without cable end - tightening torque: control circuit: 1.7 Nm - on screw fixing terminals - with screwdriver Philips No 2, control circuit: 1.7 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm, power circuit: 2.5 Nm - on screw fixing terminals - with Philips No 2 screwdriver, circuit power: 2.5 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm - operating time: 16...24 ms opening, 53.55...72.45 ms closing - Safety reliability level : B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 30 Mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

  • Warranty

    Warranty

    12 month warranty. For more information visit Termini e Condizioni

  • Return Policy

    Return Policy

    Standard. For more information visit Terms and Conditions

  • E-mail

    E-mail

    Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

  • <tc>Telephone</tc>

    Telephone

    We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

Recently viewed products

© 2024 DMS S.R.L. VAT 04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account