Description
Schneider Electric LC1D1506M7
TeSys LC1D contactor, 3 poles, AC3 440V 150A, 220 V AC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - Rated operational current [Ie]: 150 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 100 kW at 660...690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60 Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 - motor horsepower in hp: 100 hp at 460/480 V AC 50/60 Hz for 3-phase motors, 125 hp at 575/600 V AC 50 /60 Hz for 3 motor phases, 40 hp at 200/208 V AC 50/60 Hz for 3 motor phases, 50 hp at 230/240 V AC 50/60 Hz for 3 motor phases - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 1660 A at 440 V for power circuit compliant with IEC 60947, 250 A DC for signaling circuit compliant to IEC 60947-5-1 - Rated withstand short-time current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms circuit signaling, 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui] : 1000 V for power circuit compliant with IEC 60947-4-1, 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications, 600 V for signaling circuit UL certifications, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V - power dissipation per pole : 13.5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5- 1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - tightening torque: control circuit: 1.2 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, control circuit: 1.2 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw : M3.5, power circuit: 12 Nm - on connecting terminals 13 mm hexagonal nut screw: M8, power circuit: 12 Nm - on busbars 13 mm hexagonal screw: M8 - operating time: 20...35 ms closing, 40...75 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d =20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 8 mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring.In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..