LC1D1506BD | Schneider Electric

Description

Schneider Electric LC1D1506BD

TeSys LC1D contactor, 3 poles, AC3 440V150A, 24 V DC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - Rated operational current [Ie]: 150 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 100 kW at 660...690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 - motor horsepower in hp: 100 hp at 460/480 V AC 50/60 Hz for 3-phase motors, 125 hp at 575/600 V AC 50/ 60 Hz for 3 motor phases, 40 hp at 200/208 V AC 50/60 Hz for 3 motor phases, 50 hp at 230/240 V AC 50/60 Hz for 3 motor phases - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 1660 A at 440 V for power circuit compliant with IEC 60947, 250 A DC for signaling circuit compliant with IEC 60947-5-1 - Rated withstand short-time current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms signaling circuit , 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG per circuit signaling compliant with IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 1000 V for power circuit compliant with IEC60947-4-1, 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications, 600 V for signaling circuit UL certifications, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V - power dissipation per pole: 13 ,5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit : nut connection terminals - external diameter: 8 mm, power circuit: nut connection terminals - external diameter: 25 mm, power circuit: busbars 1 5 x 25 mm - tightening torque: control circuit: 1, 2 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, control circuit: 1.2 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M3.5, circuit power: 12 Nm - on connection terminals with 13 mm hexagonal nut screw: M8, power circuit: 12 Nm - on 13 mm hexagonal busbars screw: M8 - operating time: 20...35 ms closing, 40.. .75 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 8 Mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality with wiring.In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

Product form

SKU: LC1D1506BD
Barcode: 3389110483017

€528,85

  •  Su ordinazione - Consegna in 3 settimane
  • STANDARD RETURN
  • QUICK DELIVERY ASSURED
  • HS CODE: 85364900
  DOCUMENTATION

Documentation not available

Description

Schneider Electric LC1D1506BD

TeSys LC1D contactor, 3 poles, AC3 440V150A, 24 V DC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - Rated operational current [Ie]: 150 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 100 kW at 660...690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 - motor horsepower in hp: 100 hp at 460/480 V AC 50/60 Hz for 3-phase motors, 125 hp at 575/600 V AC 50/ 60 Hz for 3 motor phases, 40 hp at 200/208 V AC 50/60 Hz for 3 motor phases, 50 hp at 230/240 V AC 50/60 Hz for 3 motor phases - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 1660 A at 440 V for power circuit compliant with IEC 60947, 250 A DC for signaling circuit compliant with IEC 60947-5-1 - Rated withstand short-time current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms signaling circuit , 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG per circuit signaling compliant with IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 1000 V for power circuit compliant with IEC60947-4-1, 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications, 600 V for signaling circuit UL certifications, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V - power dissipation per pole: 13 ,5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit : nut connection terminals - external diameter: 8 mm, power circuit: nut connection terminals - external diameter: 25 mm, power circuit: busbars 1 5 x 25 mm - tightening torque: control circuit: 1, 2 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, control circuit: 1.2 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M3.5, circuit power: 12 Nm - on connection terminals with 13 mm hexagonal nut screw: M8, power circuit: 12 Nm - on 13 mm hexagonal busbars screw: M8 - operating time: 20...35 ms closing, 40.. .75 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 8 Mcycles. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality with wiring.In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

  • Warranty

    12 month warranty. For more information visit Termini e Condizioni

  • Return Policy

    Standard. For more information visit Terms and Conditions

  • E-mail

    Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

  • Telephone

    We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

Recently viewed products

© 2024 DMS S.R.L. VAT IT04742820618

DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

    • American Express
    • Apple Pay
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account