LC1D1506B7 | Schneider Electric

Description

Schneider Electric LC1D1506B7

TeSys LC1D contactor, 3 poles, AC3 440V 150A, 24 V AC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - category of use: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - Rated operational current [Ie]: 150 A (<= 60 °C) at <=440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 100 kW at 660...690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60 Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 - motor horsepower in hp: 100 hp at 460/480 V AC 50/60 Hz for 3-phase motors, 125 hp at 575/600 V AC 50 /60 Hz for 3 motor phases, 40 hp at 200/208 V AC 50/60 Hz for 3 motor phases, 50 hp at 230/240 V AC 50/60 Hz for 3 motor phases - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 1660 A at 440 V for power circuit compliant with IEC 60947, 250 A DC for signaling circuit compliant to IEC 60947-5-1 - Rated withstand short-time current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms circuit signaling, 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 1000 V for power circuit compliant with IEC 60947-4-1, 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications, 600 V for signaling circuit UL certifications, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V - power dissipation per pole: 13 ,5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit control : screw fixing terminals 1 cables 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit : screw fixing terminals 1 cables 1...2.5 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 1 cables 1...2.5 mm² - cable rigidity: solid - without cable end, control circuit: screw fixing terminals 2 cables 1...2 .5 mm² - cable stiffness: flexible - with cable end, control circuit: screw fixing terminals 2 cables 1...2.5 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals screw 2 cables 1...2.5 mm² - cable rigidity: solid - without cable end, power circuit: connector 1 cables 10...120 mm² - cable rigidity: flexible - with cable end, power circuit: connector 1 cables 10...120 mm² - cable rigidity: flexible - without cable end, power circuit: connector 1 cables 10...120 mm² - cable rigidity: solid - without cable end, power circuit: connector 2 cables 10.. .50 mm² - cable rigidity: flexible - with cable end, power circuit: 2-cable connector 10...50 mm² - cable rigidity: flexible - without cable end, power circuit: 2-cable connector 10...50 mm² - rigidity cable: solid - without cable end - tightening torque: control circuit: 1.2 Nm - on screw fixing terminals - with Philips screwdriver No 2, control circuit: 1.2 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm, power circuit: 12 Nm - on 4 mm hexagonal connector - operating time: 20...35 ms closing, 40...75 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 8 mcycles. Benefits: .. Applications: .. Benefits: Take control of the integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

Product form

IN STOCK

SKU: LC1D1506B7
Barcode: 3389110487008

€533,80

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 85364900
      DOCUMENTATION

    Documentation not available

    Description

    Schneider Electric LC1D1506B7

    TeSys LC1D contactor, 3 poles, AC3 440V 150A, 24 V AC. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - category of use: AC-1, AC-3, AC-4 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - Rated operational current [Ie]: 150 A (<= 60 °C) at <=440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power in kW: 100 kW at 660...690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60 Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 - motor horsepower in hp: 100 hp at 460/480 V AC 50/60 Hz for 3-phase motors, 125 hp at 575/600 V AC 50 /60 Hz for 3 motor phases, 40 hp at 200/208 V AC 50/60 Hz for 3 motor phases, 50 hp at 230/240 V AC 50/60 Hz for 3 motor phases - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - rated making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 1660 A at 440 V for power circuit compliant with IEC 60947, 250 A DC for signaling circuit compliant to IEC 60947-5-1 - Rated withstand short-time current [Icw]: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms circuit signaling, 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 1000 V for power circuit compliant with IEC 60947-4-1, 600 V for power circuit CSA certifications, 600 V for power circuit UL certifications, 600 V for signaling circuit CSA certifications, 600 V for signaling circuit UL certifications, 690 V for signaling circuit compliant with IEC 60947-1 - electrical life: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V - power dissipation per pole: 13 ,5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit control : screw fixing terminals 1 cables 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit : screw fixing terminals 1 cables 1...2.5 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals 1 cables 1...2.5 mm² - cable rigidity: solid - without cable end, control circuit: screw fixing terminals 2 cables 1...2 .5 mm² - cable stiffness: flexible - with cable end, control circuit: screw fixing terminals 2 cables 1...2.5 mm² - cable stiffness: flexible - without cable end, control circuit: screw fixing terminals screw 2 cables 1...2.5 mm² - cable rigidity: solid - without cable end, power circuit: connector 1 cables 10...120 mm² - cable rigidity: flexible - with cable end, power circuit: connector 1 cables 10...120 mm² - cable rigidity: flexible - without cable end, power circuit: connector 1 cables 10...120 mm² - cable rigidity: solid - without cable end, power circuit: connector 2 cables 10.. .50 mm² - cable rigidity: flexible - with cable end, power circuit: 2-cable connector 10...50 mm² - cable rigidity: flexible - without cable end, power circuit: 2-cable connector 10...50 mm² - rigidity cable: solid - without cable end - tightening torque: control circuit: 1.2 Nm - on screw fixing terminals - with Philips screwdriver No 2, control circuit: 1.2 Nm - on screw fixing terminals - with flat screwdriver Ø 6 mm, power circuit: 12 Nm - on 4 mm hexagonal connector - operating time: 20...35 ms closing, 40...75 ms opening - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1 - mechanical life: 8 mcycles. Benefits: .. Applications: .. Benefits: Take control of the integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring. In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..

    • Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT IT04742820618

    DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account