Description
Schneider Electric LC1D096SLS207
TESYS LC1D 3p AC3 440 V 9A contactor. range: TeSys - product name: TeSys D - type of product or component: contactor - abbreviated name: LC1D - contactor application: resistive load, motor control - utilization category: AC-1, AC-3 - number of poles: 3P - pole contact composition: 3 NO - Rated operational voltage [Ue]: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - Rated operational current [Ie]: 25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit, 9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit - motor power in kW : 2.2 kW at 220...230 V AC 50 Hz, 4 kW at 380...400 V AC 50 Hz, 4 kW at 415 V AC 50 Hz, 4 kW at 440 V AC 50 Hz, 5.5 kW at 500 V AC 50 Hz, 5.5 kW at 660...690 V AC 50Hz - motor power in hp: 0.33 hp at 115 V AC 60 Hz for 1 phase motors, 1 hp at 230/240 V AC 60 Hz for 1 phase motors, 2 hp at 200/208 V AC 60 Hz for 3 phase motors, 2 hp at 230/240 V AC 60 Hz for 3 phase motors, 5 hp at 460/480 V AC 60 Hz for 3 phases motors, 7.5hp at 575/600 V AC 60 Hz for 3 phase motors - coil type: low absorption - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Conventional open air thermal current [Ith] : 10 A at <= 60 °C for signaling circuit, 25 A at <= 60 °C for power circuit - nominal making capacity Irms: 140 A AC for signaling circuit compliant with IEC 60947-5-1, 250 A at 440 V for power circuit compliant with IEC 60947, 250 A DC for signaling circuit compliant with IEC 60947-5-1 - Rated short-time withstand current [Icw]: 100 A 1 s signaling circuit, 105 A <= 40 °C 10 s power circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 210 A <= 40 °C 1 s power circuit, 30 A <=40 °C 10 min power circuit, 61 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signaling circuit compliant with IEC 60947-5-1, 20 A gG at <= 690 V type 2 coordination for power circuit, 25 A gG at < = 690 V coordination type 1 for power circuit - Rated insulation voltage [Ui]: 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signaling circuit conforming to IEC 60947-1 - electrical duration: 0 .6 Mcycles 25 A AC-1 at Ue <= 440 V, 2 Mcycles 9 A AC-3 at Ue <= 440 V - power dissipation per pole: 0.2 W AC-3, 1.56 W AC-1 - protective cover: with - mounting support: rail, plate - Standards: CSA C22.2 No 60947-4-1, DIN 5510-2, EN 45545 R22 HL3, EN 45545 R26 HL3, EN/IEC 60947-4- 1, EN/IEC 60947-5-1, UL 60947-4-1 - product certifications: CCC, CSA, EAC, IEC, UL - connections - terminals: control circuit: nut connection terminals - external diameter: 8 mm , power circuit: nut connection terminals - outer diameter: 9.5 mm - tightening torque: control circuit: 1.7 Nm - on nut connection terminals - with Philips screwdriver No 2 screw: M3.5, control circuit: 1.7 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw:M3.5, power circuit: 1.7 Nm - on nut connection terminals - with Philips screwdriver No 2 screw : M3.5, power circuit: 1.7 Nm - on nut connection terminals - with flat screwdriver Ø 6 mm screw: M3.5 - operating time: 16...32 ms opening, 55...75 ms closing - Safety reliability level: B10d = 1369863 cycles Contactor with rated load compliant with EN/ISO 13849-1, B10d = 20000000 cycles Contactor with mechanical load compliant with EN/ISO 13849-1. Benefits: Take control of your integration. The Tesys D range, in addition to the renewed design, offers high electrical and mechanical technical performance, reliability and practicality of wiring.In the 40, 50 and 65A ratings, the patented EVERLINK connection system allows, in addition to the direct connection between contactor, motor protection and thermal relay, the maintenance of pressure on the conductors even in the presence of deformation of the conductors themselves. From 9 to 65A the contactors can communicate on the network thanks to specific accessories (Quick fit).... Applications: - Industry, Infrastructure, Buildings, perfect integration into control systems, ideal for starting motors in any type of application ..