Magnetothermal motor protection switch 115A 50kA Everlink. range: TeSys - product name: TeSys GV4 - abbreviated name: GV4P - type of product or component: circuit breaker - application: motor - utilization category: category A - tripping technology: electronic, magnetothermal - type of protection: short circuit, phase loss, short-term short circuit protection, earth fault protection, overload, phase imbalance - motor intervention class: 10, 20 - breaking capacity: [Icu]: 100 kA at 220...240 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 15 kA at 525 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 25 kA at 500 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 50 kA at 380...415 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 50 kA at 440 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 8 kA at 660...690 V AC 50/60 Hz according to IEC 60947-2, 18 kA at 600Y/347 V AC 50/60 Hz according to UL 60947, 35 kA at 480Y/277 V AC 50/60 Hz according to UL 60947, 65 kA at 208Y/120 V AC 50/60 Hz according to UL 60947, 65 kA at 240 V AC 50/60 Hz according to UL 60947 - Nominal service breaking capacity [Ics]: 100 kA: at 220...240 V AC 50/60 Hz according to IEC 60947-2, 15 kA: at 525 V AC 50/60 Hz according to IEC 60947-2, 2 kA: at 660...690 V AC 50/60 Hz according to IEC 60947-2, 25 kA: at 500 V AC 50/60 Hz according to IEC 60947-2, 50 kA: at 380...415 V AC 50/60 Hz according to IEC 60947-2, 50 kA: at 440 V AC 50/60 Hz according to IEC 60947-2 - type of control: lever. Benefits: easy to select, install and use double starting class to reduce the number of references Compact thanks to the new design One-click accessories 90 years of history and experience Everlink connections.. Applications: The innovative features of this new switch allow for continuity of service even in severe conditions. These products are particularly suitable for sectors such as: Oil & Gas Water treatment Mining..

Product form

BACK-ORDER

SKU: GV4PE115N
Barcode: 3606481310309

Free pickup in our shop(s)
  • HS CODE: 85362010
  • STANDARD RETURN
  • QUICK DELIVERY ASSURED

€337,28

      DELIVERY TIMES

    The delivery times for goods in the “AVAILABLE” status are usually 1 to 3 working days: the products are available in our main warehouse, ready for delivery for the quantity indicated, and the times required are those of shipping via express carrier and vary according to the destination.

    The delivery times for goods in the “AVAILABLE AT PARTNER” status are usually 3 to 5 working days and subject to unforeseeable variations.

    The delivery times for goods in the “BACK-ORDER” status are usually 2-6 weeks: contact our sales team for a precise indication

      DOCUMENTATION

    Documentation not available

    Description

    GV4PE115N SCHNEIDER ELECTRIC

    Magnetothermal motor protection switch 115A 50kA Everlink. range: TeSys - product name: TeSys GV4 - abbreviated name: GV4P - type of product or component: circuit breaker - application: motor - utilization category: category A - tripping technology: electronic, magnetothermal - type of protection: short circuit, phase loss, short-term short circuit protection, earth fault protection, overload, phase imbalance - motor intervention class: 10, 20 - breaking capacity: [Icu]: 100 kA at 220...240 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 15 kA at 525 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 25 kA at 500 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 50 kA at 380...415 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 50 kA at 440 V AC 50/60 Hz according to IEC 60947-2, [Icu]: 8 kA at 660...690 V AC 50/60 Hz according to IEC 60947-2, 18 kA at 600Y/347 V AC 50/60 Hz according to UL 60947, 35 kA at 480Y/277 V AC 50/60 Hz according to UL 60947, 65 kA at 208Y/120 V AC 50/60 Hz according to UL 60947, 65 kA at 240 V AC 50/60 Hz according to UL 60947 - Nominal service breaking capacity [Ics]: 100 kA: at 220...240 V AC 50/60 Hz according to IEC 60947-2, 15 kA: at 525 V AC 50/60 Hz according to IEC 60947-2, 2 kA: at 660...690 V AC 50/60 Hz according to IEC 60947-2, 25 kA: at 500 V AC 50/60 Hz according to IEC 60947-2, 50 kA: at 380...415 V AC 50/60 Hz according to IEC 60947-2, 50 kA: at 440 V AC 50/60 Hz according to IEC 60947-2 - type of control: lever. Benefits: easy to select, install and use double starting class to reduce the number of references Compact thanks to the new design One-click accessories 90 years of history and experience Everlink connections.. Applications: The innovative features of this new switch allow for continuity of service even in severe conditions. These products are particularly suitable for sectors such as: Oil & Gas Water treatment Mining..

    • Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      Contact us via email sales@dmstechmart.com and we will try to respond to you as soon as possible

    • Telephone

      We are available at +39 0230567159 from Monday to Friday from 09:00 to 18:00.

    Recently viewed products

    © 2025 DMS S.R.L. VAT IT04742820618

    DMSTECHMART is not a distributor or representative of the brands featured on this site. All product names, logos and trademarks are the property of their respective owners. All company, product and service names used on this site are for identification purposes only.

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account