TeSys GV 3-pole (3P) 6.3 A/690 V motor circuit breaker for high starting current peak motor applications 2.2 kW at 400 V. Provides thermal-magnetic protection with a thermal setting range 4.6-3 A, a magnetic trip level at 20 xIn, high breaking capacity Icu 100 kA at 400 V. 

Technical data
Number of poles
3P
Network type
CA
Category of use
Category A compliant with IEC 60947-2
AC-3 compliant with IEC 60947-4-1
AC-3e complies with IEC 60947-4-1
Network frequency
50/60 Hz compliant with IEC 60947-4-1
Fixing type
35mm symmetrical DIN rail: clipped on
Panel: screwed (with adapter plate)
Engine power in kW
1.1 kW at 220/230 V AC 50/60 Hz motor protection with high peak current
2.2 kW at 400/415 VAC 50/60 Hz motor protection with high peak current
2.2 kW at 440 VAC 50/60 Hz motor protection with high peak current
3 kW at 440 VAC 50/60 Hz motor protection with high peak current
3 kW at 500 VAC 50/60 Hz motor protection with high peak current
4 kW at 690 VAC 50/60 Hz motor protection with high peak current
1.6 kW at 230/240 V AC 50/60 Hz transformer protection
2 kW at 230/240 V AC 50/60 Hz transformer protection
2.5 kW at 400/415 VAC 50/60 Hz transformer protection
2.5 kW at 440 VAC 50/60 Hz transformer protection
4 kW at 440 VAC 50/60 Hz transformer protection
4 kW at 500 V AC 50/60 Hz transformer protection
4 kW at 690 VAC 50/60 Hz transformer protection
5 kW at 690 VAC 50/60 Hz transformer protection
6.3 kW at 690 VAC 50/60 Hz transformer protection
Interrupting power
100 kA Icu compliant with IEC 60947-2 at 220/230 V AC 50/60 Hz
100 kA Icu compliant with IEC 60947-2 at 400/415 V AC 50/60 Hz
50 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 Hz
50 kA Icu compliant with IEC 60947-2 at 500 V AC 50/60 Hz
3 kA Icu compliant with IEC 60947-2 at 690 V AC 50/60 Hz
Control type
Lever
Rated current [In]
6.3 A
Thermal protection adjustment range
4…6.3 A conforming to IEC 60947-4-1
Magnetic trip current
138 A

 

Product form

IN STOCK

SKU: GV2RT10
Barcode: 3389110520651

€65,50

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 85362010
      SPECIFICATIONS

    • Intervallo di regolazione relè termico (sovraccarico) - 4...6.3 A
    • Intervallo di regolazione protezione contro i cortocircuiti istantaneo - 138...138 A
    • Con protezione termica - sì
    • Rilevamento mancanza di fase - sì
    • Tipo di sganciatore - Magnetotermico

      DOCUMENTATION

    Description

    Schneider Electric GV2RT10

    TeSys GV 3-pole (3P) 6.3 A/690 V motor circuit breaker for high starting current peak motor applications 2.2 kW at 400 V. Provides thermal-magnetic protection with a thermal setting range 4.6-3 A, a magnetic trip level at 20 xIn, high breaking capacity Icu 100 kA at 400 V. 

    Technical data
    Number of poles
    3P
    Network type
    CA
    Category of use
    Category A compliant with IEC 60947-2
    AC-3 compliant with IEC 60947-4-1
    AC-3e complies with IEC 60947-4-1
    Network frequency
    50/60 Hz compliant with IEC 60947-4-1
    Fixing type
    35mm symmetrical DIN rail: clipped on
    Panel: screwed (with adapter plate)
    Engine power in kW
    1.1 kW at 220/230 V AC 50/60 Hz motor protection with high peak current
    2.2 kW at 400/415 VAC 50/60 Hz motor protection with high peak current
    2.2 kW at 440 VAC 50/60 Hz motor protection with high peak current
    3 kW at 440 VAC 50/60 Hz motor protection with high peak current
    3 kW at 500 VAC 50/60 Hz motor protection with high peak current
    4 kW at 690 VAC 50/60 Hz motor protection with high peak current
    1.6 kW at 230/240 V AC 50/60 Hz transformer protection
    2 kW at 230/240 V AC 50/60 Hz transformer protection
    2.5 kW at 400/415 VAC 50/60 Hz transformer protection
    2.5 kW at 440 VAC 50/60 Hz transformer protection
    4 kW at 440 VAC 50/60 Hz transformer protection
    4 kW at 500 V AC 50/60 Hz transformer protection
    4 kW at 690 VAC 50/60 Hz transformer protection
    5 kW at 690 VAC 50/60 Hz transformer protection
    6.3 kW at 690 VAC 50/60 Hz transformer protection
    Interrupting power
    100 kA Icu compliant with IEC 60947-2 at 220/230 V AC 50/60 Hz
    100 kA Icu compliant with IEC 60947-2 at 400/415 V AC 50/60 Hz
    50 kA Icu compliant with IEC 60947-2 at 440 V AC 50/60 Hz
    50 kA Icu compliant with IEC 60947-2 at 500 V AC 50/60 Hz
    3 kA Icu compliant with IEC 60947-2 at 690 V AC 50/60 Hz
    Control type
    Lever
    Rated current [In]
    6.3 A
    Thermal protection adjustment range
    4…6.3 A conforming to IEC 60947-4-1
    Magnetic trip current
    138 A

     

    • Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT IT04742820618

    DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account