Abb 1SBL237001R1100 - AF26-30-00-11

The AF26-30-00-11 is a 3-pole contactor - 690 V IEC or 600 UL with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) or 15 hp / 480 V UL and switching power circuits up to 45 A (AC-1) or 45 A UL for general use. Thanks to AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), handling large control voltage variations, reducing panel power consumption and ensuring distinct operations in unstable networks. In addition, surge protection is integrated, providing a compact solution. AF contactors have a block-type design, can be easily extended with additional auxiliary contact blocks and a wide range of additional accessories.

Technical:
Main Contact Number NO:
3
Main Contact Number NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage:
Main Circuit 690V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
Rated Operational Current AC-1 (Ie):
(690V) 40°C 45A
(690V) 60°C 40A
(690V) 70°C 32A
Rated Operational Current AC-3 (Ie):
(415V) 60°C 26A
(440V) 60°C 26A
(500V) 60°C 23A
(690V) 60°C 17A
(380 / 400 V) 60 °C 26 A
(220 / 230 / 240 V) 60 °C 26 A
Rated Operational Current AC-3e (Ie):
(415V) 60°C 26A
(440V) 60°C 26A
(500V) 60°C 23A
(690V) 60°C 17A
(380 / 400 V) 60 °C 26 A
(220 / 230 / 240 V) 60 °C 26 A
Rated Operational Power AC-3 (Pe):
(400V) 11kW
(415V) 11kW
(440V) 15kW
(500V) 15kW
(690V) 15kW
(380 / 400 V) 11 kW
(220 / 230 / 240V) 6.5kW
Rated Operational Power AC-3e (Pe):
(415V) 11kW
(440V) 15kW
(500V) 15kW
(690V) 15kW
(380 / 400 V) 11 kW
(220 / 230 / 240V) 6.5kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Rated Operational Current DC-1 (Ie):
(110V) 2 Poles in Series, 40°C 45A
(110V) 2 Poles in Series, 60°C 40A
(110V) 2 Poles in Series, 70°C 32A
(110V) 3 Poles in Series, 40°C 45A
(110V) 3 Poles in Series, 60°C 40A
(110V) 3 Poles in Series, 70°C 32A
(220V) 3 Poles in Series, 40°C 45A
(220V) 3 Poles in Series, 60°C 40A
(220V) 3 Poles in Series, 70°C 32A
(72V) 1-Pole, 40°C 45A
Show more
Rated Operational Current DC-3 (Ie):
(110V) 2 Poles in Series, 40°C 45A
(110V) 2 Poles in Series, 60°C 40A
(110V) 2 Poles in Series, 70°C 32A
(110V) 3 Poles in Series, 40°C 45A
(110V) 3 Poles in Series, 60°C 40A
(110V) 3 Poles in Series, 70°C 32A
(220V) 3 Poles in Series, 40°C 45A
(220V) 3 Poles in Series, 60°C 40A
(220V) 3 Poles in Series, 70°C 32A
(72V) 1-Pole, 40°C 45A
Show more
Rated Operational Current DC-5 (Ie):
(110V) 2 Poles in Series, 40°C 45A
(110V) 2 Poles in Series, 60°C 40A
(110V) 2 Poles in Series, 70°C 32A
(110V) 3 Poles in Series, 40°C 45A
(110V) 3 Poles in Series, 60°C 40A
(110V) 3 Poles in Series, 70°C 32A
(220V) 3 Poles in Series, 40°C 20A
(220V) 3 Poles in Series, 60°C 20A
(220V) 3 Poles in Series, 70°C 20A
(72V) 1-Pole, 40°C 20A
Show more
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600V
Rated Impulse Withstand Voltage (Uimp):
6kV
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50Hz 24...60V
60Hz 24...60V
DC Operation 20 ... 60 V

Product form

IN STOCK

SKU: 1SBL237001R1100
Barcode: 3471523110915

€40,50

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 853649
      SPECIFICATIONS

    Caratteristiche principali

    • Tensione nominale di comando Us 50Hz AC - 24...60 V
    • Tensione nominale di comando Us 60Hz AC - 24...60 V
    • Tensione nominale di comando Us DC - 20...60 V
    • Tipo di tensione per l'azionamento - AC / DC
    • Numero di contatti principali NC - 0

      DOCUMENTATION

    Description

    Abb 1SBL237001R1100 - AF26-30-00-11

    The AF26-30-00-11 is a 3-pole contactor - 690 V IEC or 600 UL with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) or 15 hp / 480 V UL and switching power circuits up to 45 A (AC-1) or 45 A UL for general use. Thanks to AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), handling large control voltage variations, reducing panel power consumption and ensuring distinct operations in unstable networks. In addition, surge protection is integrated, providing a compact solution. AF contactors have a block-type design, can be easily extended with additional auxiliary contact blocks and a wide range of additional accessories.

    Technical:
    Main Contact Number NO:
    3
    Main Contact Number NC:
    0
    Number of Auxiliary Contacts NO:
    0
    Number of Auxiliary Contacts NC:
    0
    Standards:
    IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
    Rated Operational Voltage:
    Main Circuit 690V
    Rated Frequency (f):
    Control Circuit 50 / 60 Hz
    Main Circuit 50 / 60 Hz
    Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
    Rated Operational Current AC-1 (Ie):
    (690V) 40°C 45A
    (690V) 60°C 40A
    (690V) 70°C 32A
    Rated Operational Current AC-3 (Ie):
    (415V) 60°C 26A
    (440V) 60°C 26A
    (500V) 60°C 23A
    (690V) 60°C 17A
    (380 / 400 V) 60 °C 26 A
    (220 / 230 / 240 V) 60 °C 26 A
    Rated Operational Current AC-3e (Ie):
    (415V) 60°C 26A
    (440V) 60°C 26A
    (500V) 60°C 23A
    (690V) 60°C 17A
    (380 / 400 V) 60 °C 26 A
    (220 / 230 / 240 V) 60 °C 26 A
    Rated Operational Power AC-3 (Pe):
    (400V) 11kW
    (415V) 11kW
    (440V) 15kW
    (500V) 15kW
    (690V) 15kW
    (380 / 400 V) 11 kW
    (220 / 230 / 240V) 6.5kW
    Rated Operational Power AC-3e (Pe):
    (415V) 11kW
    (440V) 15kW
    (500V) 15kW
    (690V) 15kW
    (380 / 400 V) 11 kW
    (220 / 230 / 240V) 6.5kW
    Rated Short-time Withstand Current Low Voltage (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
    Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
    Maximum Electrical Switching Frequency:
    (AC-1) 600 cycles per hour
    (AC-2 / AC-4) 150 cycles per hour
    (AC-3) 1200 cycles per hour
    Rated Operational Current DC-1 (Ie):
    (110V) 2 Poles in Series, 40°C 45A
    (110V) 2 Poles in Series, 60°C 40A
    (110V) 2 Poles in Series, 70°C 32A
    (110V) 3 Poles in Series, 40°C 45A
    (110V) 3 Poles in Series, 60°C 40A
    (110V) 3 Poles in Series, 70°C 32A
    (220V) 3 Poles in Series, 40°C 45A
    (220V) 3 Poles in Series, 60°C 40A
    (220V) 3 Poles in Series, 70°C 32A
    (72V) 1-Pole, 40°C 45A
    Show more
    Rated Operational Current DC-3 (Ie):
    (110V) 2 Poles in Series, 40°C 45A
    (110V) 2 Poles in Series, 60°C 40A
    (110V) 2 Poles in Series, 70°C 32A
    (110V) 3 Poles in Series, 40°C 45A
    (110V) 3 Poles in Series, 60°C 40A
    (110V) 3 Poles in Series, 70°C 32A
    (220V) 3 Poles in Series, 40°C 45A
    (220V) 3 Poles in Series, 60°C 40A
    (220V) 3 Poles in Series, 70°C 32A
    (72V) 1-Pole, 40°C 45A
    Show more
    Rated Operational Current DC-5 (Ie):
    (110V) 2 Poles in Series, 40°C 45A
    (110V) 2 Poles in Series, 60°C 40A
    (110V) 2 Poles in Series, 70°C 32A
    (110V) 3 Poles in Series, 40°C 45A
    (110V) 3 Poles in Series, 60°C 40A
    (110V) 3 Poles in Series, 70°C 32A
    (220V) 3 Poles in Series, 40°C 20A
    (220V) 3 Poles in Series, 60°C 20A
    (220V) 3 Poles in Series, 70°C 20A
    (72V) 1-Pole, 40°C 20A
    Show more
    Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 690 V
    acc. to UL/CSA 600V
    Rated Impulse Withstand Voltage (Uimp):
    6kV
    Maximum Mechanical Switching Frequency:
    3600 cycles per hour
    Rated Control Circuit Voltage (Uc):
    50Hz 24...60V
    60Hz 24...60V
    DC Operation 20 ... 60 V

    • Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT IT04742820618

    DMSTECHMART is not a distributor or representative of the brands featured on this site. All product names, logos and trademarks are the property of their respective owners. All company, product and service names used on this site are for identification purposes only.

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account