SIEMENS SITOP PSU8200 Power supply 24v 20a 6EP3436-8SB00-0AY0

SITOP PSU8200 24 V/20 A stabilized power supply input: 3 AC 400 ... 500 V output: DC 24 V/20 A *Ex approval no longer available*

Entrance

Three-phase AC power network shape
supply voltage with AC
● min. nominal value 400 V
● max. nominal value 500 V
● initial value 320 V
● final value 575 V
Input execution wide-range input Yes
operating condition of the buffer due to lack of  mains voltage
With Ue = 400 V
buffering time with nominal current value  output in case of mains voltage failure min.  15 ms
operating condition of the buffer due to lack of  mains voltage
With Ue = 400 V
network frequency
● 1 nominal value 50 Hz
● 2 nominal value 60 Hz
Mains frequency 47 ... 63 Hz
input current
● with input voltage rating 400V 1.2A
● with input voltage rating 500V 1A
current limitation of the inrush current at 25 °C max. 16 A
I2t value max. 0.8 A² s
Execution of protection No
● of the network cable Required: circuit breaker with three-pole coupling 6 ... 16 A
Characteristic C or circuit breaker 3RV2011-1DA10 (setting
on 3 A) or 3RV2711-1DD10 (UL 489)

Product form

IN STOCK

SKU: 6EP3436-8SB00-0AY0
Barcode: 4025515154440

€209,99

    • STANDARD RETURN
    • QUICK DELIVERY ASSURED
    • HS CODE: 85044083
      SPECIFICATIONS

      DOCUMENTATION

    Description

    SIEMENS SITOP PSU8200 Power supply 24v 20a 6EP3436-8SB00-0AY0

    SITOP PSU8200 24 V/20 A stabilized power supply input: 3 AC 400 ... 500 V output: DC 24 V/20 A *Ex approval no longer available*

    Entrance

    Three-phase AC power network shape
    supply voltage with AC
    ● min. nominal value 400 V
    ● max. nominal value 500 V
    ● initial value 320 V
    ● final value 575 V
    Input execution wide-range input Yes
    operating condition of the buffer due to lack of  mains voltage
    With Ue = 400 V
    buffering time with nominal current value  output in case of mains voltage failure min.  15 ms
    operating condition of the buffer due to lack of  mains voltage
    With Ue = 400 V
    network frequency
    ● 1 nominal value 50 Hz
    ● 2 nominal value 60 Hz
    Mains frequency 47 ... 63 Hz
    input current
    ● with input voltage rating 400V 1.2A
    ● with input voltage rating 500V 1A
    current limitation of the inrush current at 25 °C max. 16 A
    I2t value max. 0.8 A² s
    Execution of protection No
    ● of the network cable Required: circuit breaker with three-pole coupling 6 ... 16 A
    Characteristic C or circuit breaker 3RV2011-1DA10 (setting
    on 3 A) or 3RV2711-1DD10 (UL 489)

    • Warranty

      12 month warranty. For more information visit Termini e Condizioni

    • Return Policy

      Standard. For more information visit Terms and Conditions

    • E-mail

      Contact us via email info@dmstechmart.com and we will try to respond to you as quickly as possible

    • Telephone

      We are at your disposal for further information by telephone at +39 0230567159 from Monday to Friday from 09.00 to 18.00 (CET).

    Recently viewed products

    © 2024 DMS S.R.L. VAT IT04742820618

    DMSTECHMART non è un distributore o rappresentate dei marchi presenti su questo sito. Tutti i nomi, i loghi e i marchi dei prodotti appartengono ai rispettivi proprietari. Tutti i nomi di società, prodotti e servizi utilizzati in questo sito sono solo a scopo di identificazione.

      • American Express
      • Apple Pay
      • Google Pay
      • Maestro
      • Mastercard
      • PayPal
      • Shop Pay
      • Union Pay
      • Visa

      Login

      Forgot your password?

      Don't have an account yet?
      Create account